×

Academic Intelligence · Curated Daily

Explore the Frontier of Global Academia

AcademicHub aggregates real-time literature from top journals and preprint platforms. Build your personal research radar and let large language models compile cross-disciplinary analysis briefings automatically.

Authors: V. T. T ×
Shuffle
01.
medRxiv (Medicine) 2026-06-22

Clinical-grade Cuffless Blood Pressure Monitoring via Deep-tissue Diffuse Speckle Pulsatile Flowmetry

Blood pressure (BP) is a vital sign which is measured to diagnose and manage hypertension. However, current methods to measure BP use inflatable cuffs which cause discomfort and limit the frequency at which measurements can be made, or intra-arterial catheters which are invasive and pose infection risks. Here, we propose and evaluate the use of Diffuse Speckle Pulsatile Flowmetry (DSPF) as a cuffless BP measurement method to address these limitations. DSPF is a laser speckle-based technique which simultaneously records blood flow rate and blood volume (i.e. photoplethysmography or PPG) signals from relatively deep vascular tissue. Using information from these signals, we studied DSPFs effectiveness in measuring systolic BP (SBP) and diastolic BP (DBP) through an outpatient study in which 133 patients were recruited, and in measuring beat-to-beat BP waveforms through an inpatient study in which two patients were recruited. In the outpatient study, the DSPF method was able to achieve mean absolute errors (MAEs) of 4.17 mmHg and 2.42 mmHg for SBP and DBP respectively compared to conventional cuff-based methods. It was also able to fulfil the requirements of the AAMI/ESH/ISO 81060-2:2018 standard for BP measurement devices and attain an "A" grade according to the British Hypertension Society grading scheme. For the inpatient study, it produced BP waveforms which had MAEs of 2.35 mmHg and 3.06 mmHg compared to arterial-line measurements for the two patients, respectively. Compared to PPG which has been studied more extensively as a cuffless BP measurement method, we found through ablation studies that DSPF was able to reach significantly lower MAEs and hence better accuracies. DSPF augments the performance of PPG-only methods by leveraging additional information from the blood flow rate signal, and we therefore find it to be a superior cuffless BP measurement method which can potentially be used in outpatient, inpatient, and remote settings.

02.
arXiv (CS.CV) 2026-06-17

DiFlow-TTS: Compact and Low-Latency Zero-Shot Text-to-Speech with Discrete Flow Matching

Zero-shot text-to-speech (TTS) has made significant progress in replicating unseen voices, yet balancing generation quality and inference efficiency remains challenging. Autoregressive models suffer from high latency, while diffusion-based approaches are constrained by training-time configurations. Moreover, most flow-based methods operate in continuous space, which introduces optimization challenges because continuous token spaces are inherently more complex than discrete ones. To address these limitations, we propose DiFlow-TTS, a novel zero-shot TTS framework based on discrete flow matching. The model consists of a deterministic Phoneme-Content Mapper for linguistic modeling and a Factorized Discrete Flow Denoiser that simultaneously generates prosody and acoustic token streams. Experimental results demonstrate the effectiveness of our approach across multiple evaluation metrics.