×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: T. W ×
换一批
01.
medRxiv (Medicine) 2026-06-10

A Three-Tier Operational Benchmark for Evaluating Large Language Models on Hospital Medication Safety

Objective. To introduce PsiBench, a clinically validated medication-safety benchmark for evaluating large language models (LLMs) against the standards used to certify hospital computerized provider order entry (CPOE) and electronic health record (EHR) systems, and a non-overlapping three-tier evaluation framework separating highest-stakes discrimination, the operational CDS regime, and category-correct alerting. Materials and Methods. PsiBench comprises 492 medication-safety scenarios across 11 safety categories, created by clinical pharmacology experts whose work underpins an annualized testing procedure used by more than 2,000 U.S. hospitals. The three-tier framework partitions the scenarios non-overlappingly: Discrimination (98 scenarios, 50 fatal vs 48 deception, near-balanced 51%/49%); Operational (394 scenarios, 261 serious unsafe plus 133 safe including 41 Excessive Alerts reclassified as operational negatives); and Attribution (311 alert-required scenarios). We evaluated 40 frontier LLMs from 10 providers over 3 runs per scenario at temperature 0.2 (or the provider default where temperature is not configurable), yielding 59,040 evaluations conducted April 21-23, 2026. Results. Headline binary performance on the full benchmark spans a wide range across the 40 models: F1 78.5%-92.3%, accuracy 65.4%-89.8%, sensitivity 81.4%-100.0%, specificity 6.1%-81.8%. Leading models by F1 (o4-mini 92.3%; o3 92.2%) pair high sensitivity with meaningful specificity; three models saturate sensitivity at 100% but fall below 25% specificity, indistinguishable from a naive always-alert classifier. The wide spread on a single headline metric motivates tier-specific analyses, developed in a separate clinical paper. Discussion and Conclusion. PsiBench and the three-tier framework operationalize a rigorous evaluation rubric for LLM medication safety, grounded in two decades of national hospital audit experience. The framework generalizes to any binary medication-safety classifier (rule-based, conventional ML, or LLM-driven), supporting tier-aware model selection and post-deployment surveillance.

02.
medRxiv (Medicine) 2026-06-22

Clinical-grade Cuffless Blood Pressure Monitoring via Deep-tissue Diffuse Speckle Pulsatile Flowmetry

Blood pressure (BP) is a vital sign which is measured to diagnose and manage hypertension. However, current methods to measure BP use inflatable cuffs which cause discomfort and limit the frequency at which measurements can be made, or intra-arterial catheters which are invasive and pose infection risks. Here, we propose and evaluate the use of Diffuse Speckle Pulsatile Flowmetry (DSPF) as a cuffless BP measurement method to address these limitations. DSPF is a laser speckle-based technique which simultaneously records blood flow rate and blood volume (i.e. photoplethysmography or PPG) signals from relatively deep vascular tissue. Using information from these signals, we studied DSPFs effectiveness in measuring systolic BP (SBP) and diastolic BP (DBP) through an outpatient study in which 133 patients were recruited, and in measuring beat-to-beat BP waveforms through an inpatient study in which two patients were recruited. In the outpatient study, the DSPF method was able to achieve mean absolute errors (MAEs) of 4.17 mmHg and 2.42 mmHg for SBP and DBP respectively compared to conventional cuff-based methods. It was also able to fulfil the requirements of the AAMI/ESH/ISO 81060-2:2018 standard for BP measurement devices and attain an "A" grade according to the British Hypertension Society grading scheme. For the inpatient study, it produced BP waveforms which had MAEs of 2.35 mmHg and 3.06 mmHg compared to arterial-line measurements for the two patients, respectively. Compared to PPG which has been studied more extensively as a cuffless BP measurement method, we found through ablation studies that DSPF was able to reach significantly lower MAEs and hence better accuracies. DSPF augments the performance of PPG-only methods by leveraging additional information from the blood flow rate signal, and we therefore find it to be a superior cuffless BP measurement method which can potentially be used in outpatient, inpatient, and remote settings.

03.
medRxiv (Medicine) 2026-06-22

A Controlled Human Malaria Infection model for relapsing Plasmodium vivax

Background Plasmodium vivax malaria relapses are a major source of morbidity and onward transmission of infection. The underlying mechanisms are poorly understood and current therapies sub-optimal. We examined the safety and feasibility of a controlled human malaria infection (CHMI) model for relapsing P. vivax. Methods We conducted an open-label, proof-of-concept, CHMI study of relapsing P. vivax. Healthy, malaria-naive, Duffy-positive adults aged 18-45 years with extensive CYP2D6 metaboliser phenotype and normal blood glucose-6-phosphate dehydrogenase (G6PD) levels were recruited in Oxford, UK. Mosquito-bite CHMI was performed in Nijmegen, The Netherlands, using Anopheles stephensi mosquitoes infected with PvW1, a clonal isolate of P. vivax from Thailand. All follow-up visits were conducted in Oxford, UK. Primary P. vivax infections (qPCR > 500 genome copies/mL) were treated with artemether-lumefantrine (80mg/480mg at 8, 24, 36, 48 and 60 hours). From Day 28 following CHMI, participants attended a fortnightly clinic for clinical review and qPCR blood sampling, with additional assessments performed for any reported symptoms. P. vivax relapse infections (qPCR > 500 genome copies/mL) were treated with artemether-lumefantrine as per primary infection. Definitive anti-malarial treatment with atovaquone-proguanil (1000mg/400mg once daily for three days) and primaquine (0{middle dot}5 mg/kg/day for 14 days) was administered six months following CHMI, regardless of parasitaemia or symptoms. The primary objective was to assess the safety, feasibility and frequency of relapsing P. vivax after CHMI. Remote follow-up (5 years) is ongoing. The study is registered with ISRCTN registry (ISRCTN48625883). Findings 20 participants were screened for eligibility from 21 January 2025. Five participants (median age 22 years) underwent CHMI (five infected mosquitoes per participant) on 15 April 2025. All participants developed primary P. vivax infection and experienced at least one relapse infection. Two participants experienced a second relapse. Overall incidence rate was 3{middle dot}6 relapse infections per person-year. Solicited adverse events were mild or moderate and there were no serious adverse events. Definitive anti-malarial treatment was administered to all participants. One participant experienced primaquine-induced methaemoglobinaemia, resolving with early discontinuation of treatment (total dose 5{middle dot}3 mg/kg). To date, more than six months after primaquine treatment, no further relapses have been recorded. Interpretation CHMI of relapsing P. vivax is safe and feasible, allowing exploration of the mechanisms underlying relapse infections and providing a platform for future anti-relapse efficacy studies. Funding European Union Horizon Europe programme and UK Research and Innovation (UKRI) via OptiVivax consortium; UK National Institute for Health and Care Research Biomedical Research Centre: Oxford; and UK Medical Research Council.

04.
arXiv (quant-ph) 2026-06-16

Boson Sampling as a Probe of Chaotic and Integrable Quantum Dynamics in a Photonic Chip

arXiv:2605.25398v2 Announce Type: replace Abstract: Quantum chaos plays a key role in understanding complex quantum dynamics, while integrated photonics offers unique advantages for quantum applications, including high-speed operation, scalability, and programmable unitary transformations. However, integrated photonic approaches to probing quantum chaos remain largely unexplored, owing to the absence of a clear connection between programmable photonic dynamics and established chaos diagnostics. In this work, we establish Fock-state boson sampling as a practical probe of quantum chaos by exploiting the sensitivity of multiphoton interference to the random-matrix properties of underlying single-particle unitary dynamics. More importantly, we design and fabricate a programmable quantum photonic chip to experimentally implement this framework, achieving the first integrated-photonic demonstration of quantum-chaos probes based on boson sampling. Experimental results show that the three complementary probes proposed in this work, namely the distance to Porter–Thomas statistics, Shannon entropy, and Out-of-Time-Ordered-Correlator-equivalent observables, exhibit close agreement with theoretical predictions and consistently distinguish chaotic and integrable dynamics. Our work provides a scalable route for investigating complex quantum dynamics on programmable photonic platforms while leveraging the intrinsic advantages of boson sampling through multiphoton interference and complex output statistics.

05.
arXiv (CS.CV) 2026-06-15

MCR-VQGAN: A Scalable and Cost-Effective Tau PET Synthesis Approach for Alzheimer's Disease Imaging

Tau positron emission tomography (PET) is a critical diagnostic modality for Alzheimer's disease (AD), but its widespread clinical adoption is hindered by radiation exposure, limited availability, high clinical workload, and substantial financial costs. To address these limitations, we propose the Multi-scale CBAM Residual Vector Quantized Generative Adversarial Network (MCR-VQGAN) to synthesize high-fidelity tau PET images from structural T1-weighted MRI. MCR-VQGAN advances the standard VQGAN architecture through three enhancements: multi-scale convolutions, ResNet blocks, and Convolutional Block Attention Modules (CBAM), which collectively improve the capture of local and global features. Using 222 paired T1-weighted MRI and tau PET scans from the ADNI database, we trained and compared MCR-VQGAN against cGAN, WGAN-GP, CycleGAN, and baseline VQGAN. MCR-VQGAN achieved superior image synthesis performance across all metrics (MSE = 0.0056 +/- 0.0061, PSNR = 30.65 +/- 4.47 dB, SSIM = 0.9263 +/- 0.0469). A CNN-based AD classifier trained on real tau PET achieved comparable accuracy on real (63.64%) and synthetic (65.91%) images, indicating that diagnostically relevant features are preserved. Regional SUVR-equivalent analysis across Braak-defined ROIs further indicated strong agreement between real and synthetic tau PET (Pearson r = 0.78-0.88; ICC = 0.71-0.84), with the strongest agreement in Braak V/VI (ICC = 0.838). Together, these results suggest that MCR-VQGAN offers a promising and scalable surrogate for conventional tau PET imaging, potentially improving the accessibility of tau biomarkers for AD research and clinical workflows.

06.
arXiv (CS.CV) 2026-06-16

Post-Launch Capability Expansion of Vision-Language Models via Prompting for On-Orbit Spacecraft Inspection

Spaceborne inspection systems often deploy perception models prior to launch, after which updating model weights or expanding fixed label sets becomes operationally impractical. While supervised models can be integrated pre-flight, adding new semantic capabilities in orbit requires retraining and re-uploading parameters. We investigate whether prompt-driven vision–language models can enable post-launch semantic expansion, allowing new spacecraft components to be specified via natural-language prompts without modifying onboard weights. We evaluate zero-shot instance segmentation of spacecraft components under a strictly frozen, single-pass inference protocol on a test set of $129$ images of previously unseen satellites. Under fixed global thresholds and no post-processing, SAM3 achieves $0.385$ mAP@$0.5$ and $0.267$ mAP@$0.5{:}0.95$. Performance is strongly scale-dependent: large structural elements like spacecraft bodies ($0.639$ AP@$0.50$) and solar arrays ($0.598$ AP@$0.5$) localize reliably, while relatively small appendages like antennas ($0.221$ AP@$0.5$) and thrusters ($0.081$ AP@$0.5$) remain difficult. Prompt formulation influences performance, with structured prompts incorporating spatial and geometric descriptors yielding up to $82%$ improvement over short category-name prompts. The model operates within the memory and compute envelope of contemporary embedded GPUs, suggesting prompt-driven grounding can provide a practical mechanism for post-launch semantic extension of dominant spacecraft structures while highlighting limitations of zero-shot localization for fine-scale components under orbital domain shift.