摘要 / Abstract

Indoor vision-based localization systems are affected by detection noise, occlusions, and limited camera coverage, leading to uncertainty at multiple stages of the pipeline. While multi-camera data fusion is widely used to mitigate these issues, it is typically treated as a black-box component and evaluated solely end-to-end, obscuring its mechanistic contributions. To address this gap, this work investigates whether explicitly characterizing single-camera localization errors can be leveraged to calibrate and optimize multi-camera data fusion. We introduce a measurement-calibrated fusion approach that integrates component-wise error quantification, specifically isolating homography calibration, human detection, and motion tracking. A component-wise evaluation is conducted to quantify error contributions from homography calibration, human detection, and motion tracking. Experimental results show that data fusion improves localization accuracy compared to single-camera baselines. While measurement-calibrated fusion provides only limited improvement in absolute accuracy over standard fusion, it substantially reduces trajectory variance and improves motion smoothness, which are critical for applications requiring stable and continuous motion estimates. These results highlight the value of explicit error characterization when designing data fusion strategies for vision-based indoor positioning systems.