Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

01.
arXiv (CS.CV) 2026-06-15

WAM4D: Fast 4D World Action Model via Spatial Register Tokens

World action models (WAMs) have recently shown promise in jointly modeling future observations and executable robot actions. However, most existing WAMs still operate in 2D video or latent spaces, where visually plausible rollouts miss the 3D spatial constraints and occluded contact geometry required for precise manipulation. While geometric foundation models offer strong priors for recovering dense 3D structure and motion from visual observations, forcing WAMs to predict the dense 4D representation introduces costly geometric decoding and slows down causal action generation. To address the trade-off, we present WAM4D, a fast 4D world action model that uses lightweight spatial register tokens as training-time future-depth readouts to transfer pretrained geometric priors into a causal video-action transformer, then removes the register branch for lightweight action inference. To prevent non-causal shortcuts, we further design causal mixture attention for the Mixture-of-Transformers (MoT) WAM backbone, defining modality-specific visibility among video, action, and geometry tokens. Comprehensive experiments on RoboTwin 2.0 and challenging real-world manipulation tasks show that WAM4D improves spatial consistency and achieves competitive action prediction while maintaining efficient inference.

02.
arXiv (quant-ph) 2026-06-11

Logical error estimation from syndrome data of surface-code experiments

arXiv:2606.11496v1 Announce Type: new Abstract: Decoders for quantum error correction (QEC) experiments rely on detector error models (DEMs), which encode, for each error, its probability and the detectors and logical observables it flips. Here we show that estimating DEM event probabilities from experimental syndromes is feasible, avoids independent device benchmarking, and produces useful decoder priors for estimating and reducing decoded logical error probabilities. We evaluate our methods using open-source data from surface-code memory experiments performed on Google's Willow chip, and we carry out analogous surface-code experiments on IBM's \texttt{ibm\_miami} processor. Despite the different physical error scales of the Google and IBM devices, in both cases our estimated DEMs improve logical error probabilities relative to baseline device-informed DEMs, typically at the $5\%-10\%$ level and with larger gains in some IBM cases, without additional calibration circuits, decoder fine-tuning, or supervised fitting to logical outcomes.

03.
arXiv (CS.CV) 2026-06-18

Pre-Deployment Robustness Stress Testing for CT Segmentation Systems Using Clinically Motivated Multi-Corruption Augmentation

Deep learning-based CT segmentation systems often achieve high accuracy on clean benchmark images, but their performance may degrade under heterogeneous clinical imaging conditions such as noise, resolution loss, contrast variation, intensity shift, and artifacts. This instability can limit reliable deployment in real-world medical imaging workflows. We propose Robustness via Augmented Multi-corruption Pipeline (RAMP), a robustness-oriented augmentation framework for CT segmentation. RAMP combines anatomically constrained spatial perturbations, CT intensity transformations, and stochastic multi-corruption composition to expose models to clinically plausible image degradation during training. Across two CT segmentation evaluation settings, RAMP achieved the strongest corrupted-image performance and the smallest clean-to-corrupted robustness gap. In the five-organ noisy evaluation benchmark, RAMP improved mean corrupted Dice from 0.610 to 0.753 and reduced the robustness gap from 0.264 to 0.064 compared with the nnU-Net baseline. In Abdomen1K, RAMP improved mean corrupted Dice from 0.633 to 0.789 and reduced the robustness gap from 0.290 to 0.070. Although RAMP did not achieve the highest clean-image Dice, it substantially mitigated worst-case segmentation collapse under severe image degradation. These results suggest that multi-corruption augmentation can serve as a practical pre-deployment strategy for improving the reliability of CT segmentation systems in heterogeneous clinical environments.

04.
medRxiv (Medicine) 2026-06-15

Anti-Platelet Factor 4 Antibody Clonal Heterogeneity and MGUS Status in HIT

Background Monoclonal gammopathy of thrombotic significance (MGTS) is a recently described chronic prothrombotic condition characterized by monoclonal anti-PF4 antibodies that are detected above the polyclonal antibody background in patient sera (i.e. present as monoclonal gammopathy of undetermined significance, MGUS). Due to conflicting data in the published literature on antibody clonality in heparin-induced thrombocytopenia (HIT), we evaluated clonality and abundance of anti-PF4 antibodies in HIT, including investigating whether an MGUS, if present in HIT, represents the causative anti-PF4 antibody. Methods Blood samples from 15 patients with HIT were subject to Platelet Factor 4-dependent antigen-based and functional tests. The unmanipulated serum antibody repertoire and isolated anti-PF4 antibodies were subjected to mass spectrometric evaluation. Results Two of the 15 HIT patients had an IgG MGUS. Notably, anti-PF4 antibodies were not synonymous with the MGUS antibody in either of the two patients. Eight of the 15 patients demonstrated monoclonal anti-PF4 antibodies, however, none of the anti-PF4 antibodies were detectable as an MGUS upon evaluation of the entire serum antibody repertoire, reflecting their low abundance. In the seven patients with multiple anti-PF4 antibodies, non-monoclonality was confirmed by analysis of deglycosylated antibody heavy chains. Conclusions Anti-PF4 HIT antibodies are monoclonal in approximately 50% of HIT patients, however, antibody abundance is low such that they are not detectable over the polyclonal IgG background (i.e. are MGUS-negative), differentiating HIT from MGTS. This observation helps explain the transient nature of HIT relative to the persistent prothrombotic state seen in MGTS.

05.
arXiv (CS.CV) 2026-06-11

MSUE: Multi-Modal Soccer Understanding Expert

This paper presents our solution to the 2026 SoccerNet VQA Challenge. We first develop a cost-effective data synthesis pipeline driven by a Vision-Language Model (VLM), which systematically restructures raw domain data into diverse VQA samples, including concise answers and long-form responses. Second, we propose MSUE, a multi-expert question answering architecture that employs a Large Language Model (LLM) to dynamically dispatch questions to text, image, and video experts. These experts are instantiated as a strong text baseline Gemini3-Flash, a fine-tuned Qwen3-VL, and an external knowledge base, respectively, working collaboratively to enhance VQA performance. MSUE achieves an accuracy of 0.95 on the challenge benchmark, securing third place in the leaderboard.

06.
arXiv (CS.LG) 2026-06-12

Single vs. Multiple Branches in DeepONet and S-DeepONet: Network Architecture Follows Coupling in Multiphysics Systems

arXiv:2507.03660v2 Announce Type: replace Abstract: `Real-time prediction of complex physical systems requires surrogate models that learn from data while representing strong multiphysics coupling. Deep Operator Networks have shown success in single-physics problems, yet their effectiveness in capturing nonlinear interactions in coupled systems (such as thermo-mechanical or electro-thermal coupling) remains underexplored. Here we pose a practical question: should the architecture of a neural operator reflect the strength of physical coupling it aims to model? We compare single-branch and multi-branch designs, in both feedforward and sequential recurrent forms, across three representative systems: a reaction–diffusion problem with heterogeneous sources, a nonlinear thermo-electrical problem with temperature-dependent conductivity and Joule heating, and a viscoplastic thermo-mechanical model of steel solidification. Single-branch networks consistently outperform multi-branch variants in tightly coupled regimes by encouraging shared latent representations, whereas multi-branch designs remain favorable for decoupled or single-physics tasks. Once trained, these surrogates deliver full-field predictions up to $1.8 \times 10^4$ times faster than physics-based solvers.

07.
medRxiv (Medicine) 2026-06-17

What Urine Measures Is Not What Tissue Encodes: Compartment-Specific miRNA Coordination in Prostate Cancer

Abstract Background Prostate cancer (PCa) diagnosis remains challenged by the limited specificity of prostate-specific antigen (PSA) testing, which cannot reliably distinguish malignancy from benign prostatic hyperplasia (BPH). MicroRNAs (miRNAs) are emerging candidates for liquid biopsy-based diagnostics, but most studies assess expression in isolation within a single compartment (biological source - Tissue, blood, serum, urine etc.), overlooking both compartment-specific behavior and the coordinated relationships among miRNAs. Methods We profiled four candidate miRNAs — miR-19b-3p, miR-21-5p, miR-101-3p and miR-375-3p, across four biological compartments (prostate tumor tissue, urine, serum, and blood) in 179 patients undergoing prostate biopsy for clinical suspicion of PCa (104 PCa, 75 BPH) using qRT-PCR. Urinary exosomal RNA was isolated with a commercial exosome isolation kit so from here onwards this compartment will be referred to as urine. Differential expression was quantified using Cohen's d; inter-miRNA coordination was assessed via Spearman correlation and differential correlation ({delta} r) analysis; and a compartment-level network rewiring score was derived as the sum of {delta} r| across miRNA pairs. Cross-compartment structural alignment was evaluated by comparing correlation patterns at the population level. Diagnostic models combining PSA, age, and urinary exosomal-miRNA features were evaluated using Logistic Regression, Elastic Net Logistic Regression and Naive Bayes classifiers under leave-one-out cross-validation (LOOCV). Results Effect sizes were largest and most consistent in urine, with miR-101-3p showing the strongest separation between PCa and BPH (d = -1.01), followed by miR-21-5p (d {approx}-0.72$) and miR-19b-3p (d {approx}-0.64). Two markers (miR-19b-3p, miR-375-3p) showed directional reversals across compartments, indicating that disease-associated signals are compartment-specific rather than uniformly conserved. In tumor tissue, PCa was associated with substantial reorganization of inter-miRNA coordination (network rewiring score = 2.46), including the emergence of a strong miR-21-5p–miR-375-3p co-regulatory axis ({delta} r = +0.87$) and decoupling of the miR-21-5p–miR-19b-3p relationship ({delta}r = -0.64$). Urine showed a structurally distinct coordination pattern (rewiring score = 1.77), dominated by a miR-101-3p–miR-19b-3p axis (r = +0.56) absent from tissue; cross-compartment comparison showed concordance in only 1 of 5 miRNA pairs, indicating that urine's architecture is largely independent of tissue's. For diagnostic translation, the conventional PSA cutoff (4 ng/mL) achieved 100% sensitivity but only 23.5% specificity. In urine, miR-101-3p performs better than other miRNAs, with AUC of 0.77 (95% CI: 0.62–0.90). Adding PSA and age to the urinary miR-101-3p further improved discrimination to an AUC of 0.91 (95% CI: 0.82–0.99), with 70% specificity at 92% sensitivity; this pattern was consistent across Elastic Net and Logistic Regression classifiers. Expanding the model to include all urinary miRNAs, age, and pair-derived coordination features did not improve on this result (AUC = 0.88), indicating that population-level coordination changes did not translate into additional individual-level diagnostic value in this cohort. Conclusions miRNA signals in extracellular compartments do not represent direct surrogates of tumor-level molecular architecture; each compartment harbors a distinct, transformed coordination structure reflecting its biological context. While these coordination-level changes are mechanistically informative, the most direct translational gain in this study came from a parsimonious model combining PSA, age with a single urinary marker, miR-101-3p, which improved AUC from 0.77 to 0.91, with specificity 70.5% at 90% sensitivity criteria. This combination represents a promising, interpretable candidate for reducing unnecessary prostate biopsies, pending validation in larger, independent cohorts. Keywords: MicroRNA, Compartment-Specific Biomarkers, Urinary Exosomes, Differential Correlation, Liquid Biopsy, Machine learning, PSA, Early diagnosis

08.
arXiv (CS.AI) 2026-06-16

Unifying Post-hoc Explanations of Knowledge Graph Completions

arXiv:2507.22951v2 Announce Type: replace Abstract: Knowledge Graphs organize information as entity-relation-entity triples, enabling machine learning models to predict plausible missing triples in a task known as Knowledge Graph Completion (KGC). Post-hoc explainability for KGC addresses the problem of identifying which triples most influence the predictions of machine learning models. Currently, the field lacks formalization and consistent evaluations, hindering reproducibility and cross-study comparisons. This paper argues for a unified taxonomy for post-hoc explainability in KGC. First, we propose a characterization of post-hoc explanations via multi-objective optimization that unifies existing post-hoc explainability algorithms in KGC and the explanations they produce, balancing explanation effectiveness and conciseness. Next, we examine improved evaluation protocols based on popular metrics, such as Mean Reciprocal Rank and Hits@k, through illustrative experiments. Finally, we stress the importance of interpretability as the ability of explanations to address queries meaningful to end users. By unifying methods and discussing evaluation standards, this work puts forward a case for more reproducible and impactful research in KGC explainability.

09.
arXiv (quant-ph) 2026-06-11

Exploring Variational Entanglement Hamiltonians

arXiv:2505.10530v3 Announce Type: replace Abstract: Recent advances in analog and digital quantum-simulation platforms have enabled exploration of the spectrum of entanglement Hamiltonians via variational algorithms. In this work we analyze the convergence properties of the variationally obtained solutions and compare them to numerically exact calculations in quantum critical systems. We demonstrate that interpreting the cost functional as an integral permits the deployment of iterative quadrature schemes, thereby reducing the required number of measurements by more than an order of magnitude even in the presence of noise. We further show that a modified ansatz captures deviations from the Bisognano-Wichmann form in lattice models, improves convergence, improves trainability and provides a cost-function-level diagnostic for quantum phase transitions. Finally, we establish that a low cost value does not by itself guarantee convergence in trace distance. Nevertheless, it faithfully reproduces degeneracies and spectral gaps, which are essential for applications to topological phases.

10.
arXiv (CS.CV) 2026-06-19

ViCoStream: Streaming VideoLLMs Can Run Beyond 100 FPS with Stage-Wise Coordinated Inference

Streaming VideoLLMs must continuously process incoming video while maintaining low query latency, making both video-ingestion throughput and query-time responsiveness critical for real-time deployment. Existing methods largely focus on accelerating individual modules, such as visual encoding, token pruning, or KV-cache compression, but provide limited insight into whether the resulting system can sustain real-time streaming performance. We formulate streaming VideoLLM inference as a coordinated pipeline spanning visual preprocessing, visual encoding, token dropping, and LLM prefilling/decoding. Building on this formulation, we propose ViCoStream (Video Coordinated Streaming), a stage-wise coordinated streaming framework that combines chunk-wise execution, CUDA-stream overlap, visual token control, bounded visual attention, and query-side retrieval to bound per-chunk computation and memory costs. We further provide a systematic study of bottleneck migration, revealing how chunk size, token retention, attention locality, and retrieval scope shape the throughput-accuracy trade-off. Experiments with Qwen2.5-VL-3B/7B-Instruct across multiple streaming benchmarks show that ViCoStream achieves 134 FPS video throughput and less than 50 ms TTFT on a single A100 GPU while maintaining accuracy close to full-history baselines.

11.
medRxiv (Medicine) 2026-06-15

Entity-Aware Generation of Synthetic Clinical Progress Notes for Prostate Cancer using Large Language Model

Objectives: This study investigates large language models (LLMs) for clinical entity projection across substantial textual transformation. Specifically, we evaluate whether entities annotated in Spanish prostate cancer case reports can be preserved and explicitly projected when the source narratives are transformed into hospital-style clinical progress notes. Entity projection is treated as a generation-driven task, allowing paraphrase, condensation and narrative reorganisation, providing that clinically relevant entities remain recoverable as structured annotations. Methods: A corpus of 109 Spanish prostate cancer case reports was annotated using a silver-standard pipeline combining Spanish biomedical named-entity recognition with rule-based prostate-specific antigen (PSA) and Gleason extractors. The resulting silver-standard annotations were validated on a subset of generated notes against a gold-standard consensus produced by medical experts in prostate cancer. Four LLMs were evaluated for note generation and entity projection: GPT-5.4 Nano, Qwen 3.5:35B-A3B, GLM5 and Claude Sonnet 4.6. Entity-to-Entity (E2E) generation used XML-annotated cases as RAG-supported input, whereas Text-to-Entity (T2E) generation required models to generate and annotate notes directly from plain text cases. Zero-shot and few-shot prompting were tested. Projection quality was measured using precision, recall and F1-score, and complemented by LLM-as-a-judge evaluation using Kimi K2.6. Results: E2E consistently outperformed T2E, indicating that explicit entity-enriched in- put substantially facilitates entity preservation and localisation. GLM5 achieved the best E2E zero-shot result (F1 = 0.915), followed by Claude Sonnet 4.6 (F1 = 0.896). In T2E, few-shot prompting improved performance, with Claude Sonnet 4.6 reaching the highest score (F1 =0.718). Age, Gleason, Disease, Procedure, Duration and negation-related entities were robustly projected, whereas PSA and Dose showed less stable behaviour. Conclusion: LLMs can generate clinically plausible synthetic prostate cancer evolution notes while preserving a substantial proportion of source entities, particularly when explicit semantic annotations are provided as input. However, the lower and more variable performance observed in T2E highlights the difficulty of jointly generating clinical narratives and projecting entities without source-side information, especially for numerical and measure-related entities.

12.
arXiv (CS.CV) 2026-06-11

Cross-Modal Benchmarking for Robotic Perception in Natural Environments

Natural environments present a complex challenge to robotics perception systems. Current models, particularly vision foundation models, are largely trained on structured, urban environments leading to weaknesses in their perception for field robotics tasks. We showcase the limitations of current models using our recently released WildCross benchmark, a new cross-modal benchmark for place recognition and metric depth estimation in large-scale natural environments. WildCross comprises over 476K sequential RGB frames with semi-dense depth and surface normal annotations, each aligned with accurate 6DoF pose and synchronized dense lidar submaps. In this work, we provide an expanded analysis of the benchmark results from the recent WildCross benchmark, with particular emphasis on expanded metric depth estimation experiments. Access to the code repository and dataset for this work can be found at https://csiro-robotics.github.io/WildCross.

13.
Science (Express) 2026-06-18

Dynamic asymmetric strain imprinted into substrates by an oxide thin film | Science

作者: 未知作者

In film-substrate systems, the substrate role is often considered to be limited to providing static mechanical constraints. Dynamic film-substrate interactions when a structural change in the film modifies the substrate are generally disregarded. Using combined X-ray and electron microscopies, we observed that the electrically induced filament in a VO 2 film created strong asymmetric strain in the underlying Al 2 O 3 substate. This asymmetric substrate strain fed back into the film and defined the filament expansion direction, revealing the importance of film-substrate dynamic interactions in determining film functionality. Furthermore, the strain imprint propagated at least tens of microns deep into the substrate, exceeding the film thickness more than 200 times, potentially enabling substrate functionalization as an active mechanical coupling media in 3D-integrated microelectronics architectures.

14.
arXiv (CS.CL) 2026-06-11

GrowLoop: Self-Evolving Conversation Evaluation Seeded by Human

With the rapid advancement of large language models, evaluating human-likeness in open-ended conversation has become increasingly important. However, human-likeness is a form of tacit knowledge that humans perceive intuitively, yet the underlying criteria resist explicit formulation. Human judgments vary widely, with strong agreement on some cases and legitimate disagreement on others. Meanwhile, the criteria behind human judgments remain implicit, leaving no clear basis for constructing cases. Further, what counts as human-likeness is not static, but evolving with model capability and human expectations. Despite progress in evaluation methods such as expert-authored benchmarks, Reward Models, and self-evolving benchmarks, none addresses all three challenges simultaneously. Therefore, we propose GrowLoop, a self-evolving conversation evaluation system that continuously adapts as models advance and scenarios shift. Starting from minimal human seed annotations, LLM agents iteratively extract and refine evaluation rubrics through Heuristic Learning. Human-AI agreement is required where annotators converge, while only plausibility is expected where they diverge. Moreover, the Rubric-Case co-evolution mechanism enables continuous evolution. When the evaluation target shifts, new human seeds expand the system's coverage accordingly. When applied to human-likeness evaluation in open-ended conversation, the AI judge guided by these rubrics not only substantially outperforms existing methods in alignment with human judgments, but also uncovers issues that annotators overlook. The resulting benchmark effectively discriminates models across capability tiers and reveals where they fall short, while generalizing to new scenarios and adapting as models advance. Our work shifts the benchmarking paradigm from manual updates or difficulty scaling to comprehensive, continuous self-evolution.

15.
arXiv (CS.CL) 2026-06-18

RECOM: A Validity Discrimination Tradeoff in Automatic Metrics for Open Ended Reddit Question Answering

Automatic metrics are the default for evaluating LLM-generated text, yet a metric is quietly asked to do two jobs: tell genuine content alignment from surface coincidence (validity), and tell a better system from a worse one (discriminative power). On open-ended, opinion-driven question answering, the two are in tension. We introduce RECOM (Reddit Evaluation for Correspondence of Models), a contamination-free evaluation dataset of 15,000 r/AskReddit questions (September 2025), each paired with its authentic community replies, which postdate every evaluated model's training cutoff. Scoring five open-source LLMs (7–10B) against every reply each metric paired with a random-derangement noise floor we find that no metric does both jobs well. Cosine similarity separates real from random answers (Cohen's $d \approx 2$) but cannot rank the five models ($|d| < 0.1$); BERTScore precision appears to rank the models (raw $|d|$ up to 0.63), but once response length is controlled this collapses to $|d| = 0.09$ and its validity is weak ($d \approx 0.8$, versus cosine's $\approx 2$). Because every metric scores the same outputs, this validity–discrimination tradeoff is a property of the metrics, not the models, and we argue it stems from representation design. Three independent LLM judges reproduce the validity gap and likewise separate the five models only weakly. We recommend reporting metrics on both axes, with an explicit random-baseline floor. RECOM is publicly available at https://anonymous.4open.science/r/recom-D4B0

16.
arXiv (CS.CV) 2026-06-15

A Lightweight Fiducial-Based Pipeline for 3D Hyperspectral Mapping of ex-vivo Lumpectomy Specimens

Hyperspectral Imaging (HSI) is a promising modality for intraoperative assessment of resection margins in Breast-Conserving Surgery (BCS), but its clinical translation requires aligning the inherently 2D spectral information onto the 3D shape of the excised tissue so that suspicious regions can be precisely localized for targeted follow-up. We present a fully automated, calibration-free pipeline that produces a 3D hyperspectral point cloud of an ex-vivo lumpectomy specimen from a set of consumer-camera RGB images and a single top-down HSI acquisition. The 3D geometry is reconstructed with a deep-learning Structure-from-Motion backbone, stabilized in a metric reference frame by a custom bundle adjustment that enforces consistency on the corners of four ArUco markers placed around the specimen. The HSI cube is then registered to the reconstruction without recovering the HSI camera pose: the markers, visible in both modalities, define 16 corner correspondences that drive a planar homography, and 3D coordinates are recovered by lookup on an orthographically rendered depth map. Evaluated on two ex-vivo lumpectomy specimens, the pipeline achieves a median 3D registration error below 1~mm and a 2D reprojection error below 0.02 mm, with a total per-specimen processing time under 4 minutes on accelerated hardware. These results support the feasibility of integrating HSI-guided spatial localization into intraoperative margin assessment workflows for breast-conserving surgery.

17.
arXiv (CS.LG) 2026-06-18

Regular Fourier Features for Nonstationary Gaussian Processes

arXiv:2602.23006v2 Announce Type: replace-cross Abstract: Simulating a Gaussian process requires sampling from a high-dimensional Gaussian distribution, which scales cubically with the number of sample locations. Spectral methods address this challenge by exploiting the Fourier representation and treating the spectral density as a probability distribution suitable for Monte Carlo approximation. Although this probabilistic interpretation is valid for stationary processes, it is overly restrictive for the nonstationary case, where spectral densities are generally not probability measures. We propose regular Fourier features for harmonizable processes to avoid this limitation. Our method discretizes the spectral representation directly, preserving the correlation structure among spectral weights without requiring probability assumptions. Under a finite-spectral-support assumption, this yields an efficient low-rank approximation that is consistent and positive semi-definite by construction. When the spectral density is unknown, the framework extends naturally to kernel learning from data. We demonstrate the method on locally stationary and harmonizable mixture kernels, the latter with a complex-valued spectral density, and apply the kernel-learning extension to real and synthetic data.

18.
arXiv (CS.LG) 2026-06-11

Attention by Synchronization in Coupled Oscillator Networks

arXiv:2606.12059v1 Announce Type: new Abstract: We address transformer attention on energy-constrained physical substrates. Softmax attention requires exponentiation and global reduction, operations with high energy cost on von Neumann hardware and no natural physical analog. We show that Kuramoto synchronization dynamics (which arise in electrical, mechanical, superconducting, and charge-density-wave oscillator arrays, among other physical systems) implement a well-defined attention operation without either. The resulting mechanism, fixed-query oscillator attention, replaces softmax's arithmetic with the equilibration of a gradient flow on the sphere: queries are learned anchors fixed on the sphere, and free oscillators evolve under Kuramoto-Lohe dynamics until they settle at positions encoding attention weights via cosine similarity. Because the computation is equilibration, it requires no exponentiation; the only global operation is an affine normalization at readout. The fixed point is provably unique and globally attractive from almost every initial condition, a guarantee that holds across every physical realization. Empirically, at the minimal hardware configuration (oscillator dimension $d_{\mathrm{osc}}$ = 2), oscillator attention outperforms softmax on keyword spotting (+1.00 pp) and on subject-verb agreement (+5.27 pp on hard sentences, with zero training failures versus one in five for softmax). On causal language modeling, where softmax retains an advantage, oscillator attention closes the gap as $d_{\mathrm{osc}}$ grows: from +11.09 PPL at $d_{\mathrm{osc}}$ = 2 to +2.98 PPL at $d_{\mathrm{osc}}$ = 32 on WikiText-2, and from +2.39 PPL at $d_{\mathrm{osc}}$ = 2 to +0.57 PPL at $d_{\mathrm{osc}}$ = 32 on TinyStories. The main objective of this work is not to replace softmax in software but to provide a mathematically grounded blueprint for accurate attention on physical substrates.

19.
arXiv (CS.CL) 2026-06-15

A Computational Audit of Demographic Association Encoding in ClinicalBERT Language Predictions

Transformer-based clinical language models are increasingly integrated into high-stakes clinical decision support pipelines, yet the computational mechanisms through which demographic associations encoded in medical documentation propagate into model probability distributions remain empirically underspecified. We present a systematic computational audit of representational bias in ClinicalBERT (Alsentzer et al., 2019), a BERT-based model pretrained on MIMIC-III discharge summaries, employing two complementary probing methodologies: Log Probability Bias Analysis (LPBA), which quantifies demographic descriptor-induced shifts in masked token probability distributions across behavioral and evaluative semantic categories, and Masked Language Model-based analysis (MLM), which probes internal representational structure for demographic agency attribution encoding across 98 real clinical sentence templates and eight intersectional race-gender combinations. Corpus frequency analysis operationalizes the distinction between statistical disparity and bias amplification by benchmarking model outputs against empirical term frequencies in the MIMIC-III training corpus. Of 32 statistically significant findings, 65.6% contradict observed corpus distributions, rising to 80% for Black patients and 87.5% for agency attribution under MLM probing, providing direct empirical evidence that representational bias in ClinicalBERT operates predominantly through model-internal amplification rather than training data inheritance. Keywords: natural language processing, clinical documentation, algorithmic auditing, representational bias, health equity 1

20.
arXiv (CS.AI) 2026-06-15

A Benchmark and Framework for Evaluating Next Action Predictions in Spreadsheets

arXiv:2606.13802v1 Announce Type: cross Abstract: Predictive code completion greatly accelerates how quickly developers work. In spreadsheets, despite being much more common, such auto-completion features are virtually non-existent. To address this gap, we introduce a benchmark for systems that observe a sequence of user actions in a spreadsheet and predict future actions. Two challenges are (1) the absence of edit histories in public spreadsheet corpora and (2) the complex space of spreadsheet actions (spatial, temporal, composite). To address (1), we manually curate 52 sequences of 12K actions that recreate spreadsheets from public corpora, seeded by parametrized heuristics and LLM refinement. To address (2), we propose an online evaluation that expects a prediction after each user action, accepts or rejects that prediction, updates the future actions upon acceptance, and repeats this until the target spreadsheet is obtained. We use multiple baseline predictors (including zero-shot LLMs, fine-tuned SLMs, and classical models) and analyze different properties that our benchmark teaches us, including but not limited to: properties of saved actions and false positives, efficiency, effect of user profiles, effect of triggers, and effect of context.

21.
arXiv (CS.CV) 2026-06-18

Simple Domain Generalization Methods are Strong Baselines for Open Domain Generalization

In real-world applications, a machine learning model is required to handle an open-set recognition (OSR), where unknown classes appear during the inference, in addition to a domain shift, where the data distribution differs between the training and inference phases. Domain generalization (DG) aims to handle the domain shift situation where the target domain of the inference phase is inaccessible during the model training. Open domain generalization (ODG) considers DG and OSR. Domain-augmented meta-learning (DAML) is a method targeting ODG; however, it has a complicated learning process. By contrast, although various DG methods have been proposed, they have not been evaluated in ODG situations. In this study, we comprehensively evaluate the existing DG methods in ODG and show that the two simple DG methods, CORrelation ALignment (CORAL) and maximum mean discrepancy (MMD), are competitive with DAML in several cases. In addition, we propose simple extensions of CORAL and MMD by introducing the techniques used in DAML, such as ensemble learning and Dirichlet mixup data augmentation. The experimental evaluation demonstrates that the extended CORAL and MMD can perform comparably to DAML with lower computational costs. This suggests that the simple DG methods and their simple extensions are strong baselines for ODG.

22.
arXiv (CS.AI) 2026-06-12

M*: A Modular, Extensible, Serving System for Multimodal Models

arXiv:2606.12688v1 Announce Type: cross Abstract: We are entering a new era of composite model architectures that integrate diverse components such as vision encoders, language backbones, diffusion and flow heads, audio codecs, action generators, and world-model predictors. Such architectures underpin a broad class of multimodal models, including unified multimodal models, omni models, speech-language models, vision-language-action policies, and world models. However, existing model serving frameworks were built on narrow assumptions about model structure, making them ill-suited to accommodate this new architectural diversity. Here we present M*, a universal serving system for efficient serving of composite AI models. M* represents models as dataflow graphs, processing requests spanning diverse modalities and tasks as traversals over these graphs. The core insight is a modular abstraction that supports arbitrary composition of model components, flexible placement onto a physical cluster, and model-agnostic optimizations within a distributed runtime. We call this abstraction the Walk Graph and show how it can concisely capture composite models from a broad range of families. We instantiate M* on representative models and find that it achieves, on average, 20% lower end-to-end latency than vLLM-Omni for text-to-image workloads on BAGEL, while delivering up to 2.9x lower real-time factor and 2.7x higher throughput for text-to-speech workloads on Qwen3-Omni. M* also outperforms the V-JEPA 2-AC rollout baseline for robotic planning by up to 12.5x. Thus, our work paves the road towards more efficient serving of complex models with minimal developer effort.

23.
arXiv (CS.CV) 2026-06-12

SemanticXR: Low Power and Real-time Queryable Semantic Mapping with an Object-Level Device-Cloud Architecture

Semantic mapping is a core service that enables grounded interactions in emerging Extended Reality (XR) applications such as AI assistants and spatial object search. Deploying this capability on mobile XR devices requires a system that is open-vocabulary, real-time, and low-power. Existing approaches are compute-intensive and assume server-class resources. Cloud offloading offers a practical path, but no existing system splits semantic mapping across the device-cloud boundary or manages its communication, execution, and memory footprint. We present SemanticXR, the first device-cloud system for real-time, open-vocabulary semantic mapping and querying under XR power, bandwidth, and memory constraints. Our key insight is to elevate semantically identifiable objects to first-class units of communication, execution, and memory across the device and server. On the server, object-level parallelism and geometry downsampling improve mapping latency, while object-level depth-mapping co-design reduces upstream bandwidth. On the device, an object-level sparse local map with incremental updates and update prioritization enables network-robust querying with bounded memory and downstream bandwidth. Object-level configurable resource usage vs. quality trade-offs let applications and the system adapt mapping to application requirements and operating conditions, respectively. Against a device-cloud baseline with the same perception models, object-level organization improves server-side mapping latency by 2.2X at equal semantic quality. Depth-mapping co-design maintains upstream bandwidth under 2.5 Mbps. On the device, SemanticXR sustains sub-100 ms query latency for up to 10,000 objects even under network drops, supports tens of thousands of objects within 500 MB, and scales downstream bandwidth with map changes, not total scene size. The system adds only 2% device power during normal operation.

24.
arXiv (CS.CL) 2026-06-16

Can LLM Coding Agents Reason About Time Series?

Large language models (LLMs) are increasingly being used for automated decision-making systems in finance, healthcare, or environmental monitoring. Time series data are ubiquitous in these fields, yet hard to process automatically. Can time series be analyzed by LLM agents? We examine three approaches: providing the agent with raw numerical data, using the LLM as a coding agent, or a combination of both. In the coding agent setup, the model iteratively queries the data using Python code. Using two time series understanding benchmarks, we show that agents with code access can outperform models processing raw data by up to 10%. However, even the best performing agent still answers about 22-34% of the questions incorrectly. To get insights into models' strategies and reasoning gaps, we analyze the model outputs with a strong LLM judge. Our analysis reveals that coding agents can select appropriate statistical tests, but often miss important nuances. Meanwhile, models with access to raw data can reach the right conclusions using back-of-the-envelope calculations.

25.
medRxiv (Medicine) 2026-06-12

Integrative Mechanisms of Early Clinical and Research Training (ECART) in Orthopaedic Medical Education: A Qualitative Single-Case Study

Background: Early clinical exposure and student participation in research are important components of medical training. They may support learning motivation, evidence literacy, and self-directed learning. In many programmes, however, clinical training and research training remain separated. Few studies have explained, within a real teaching team, how learners turn clinical phenomena into researchable questions and how research participation can reshape their clinical understanding. Early Clinical and Research Training (ECART) is a clinical-research integration approach developed by an orthopaedic team at the Second Hospital of Shandong University. Methods: We conducted a theory-informed, interpretivist qualitative single-case study. The case was an orthopaedic clinical-research team at the Second Hospital of Shandong University. Participants included medical undergraduates, academic degree graduate students, professional degree graduate students, clinical teachers, and research platform leads. We used purposive sampling with maximum variation. Data were collected through semi-structured interviews and de-identified teaching documents. Data were analysed using the framework method and were interpreted with a Context-Activity-Mechanism-Outcome (CAMO) logic. Results: The analysis showed that ECART was not simply early entry into the clinic or early entry into the laboratory. It was a team-based learning process centred on real medical problems. Four themes were identified. First, early clinical exposure helped learners make real problems visible and nameable, rather than merely increasing exposure. Second, clinical-research connection followed different pathways. Professional degree graduate students often started from clinical uncertainties in residency training and case management, and moved toward evidence-informed small projects. Academic degree graduate students often started from literature gaps, experimental findings, and mechanistic hypotheses, and then used clinical feedback to calibrate meaning. Third, research training, through literature reading, group meetings, experimental design, data review, and mentor questioning, helped learners move from completing tasks to explaining problems. Fourth, sustained ECART depended on a tiered team ecology formed by clinical teachers, research mentors, research platforms, and senior peers. Based on these findings, we refined the ECART programme theory: real medical problems are translated through explanation, searching, experimentalisation, and feedback-based reinterpretation into research questions that learners can understand, discuss, and test. This process supports problem formation, evidence awareness, mechanistic reasoning, translational judgement, and career clarification. Conclusion: ECART is best understood as a clinical-research integrated learning ecology that emerges from real team practice, rather than as a fixed standardised course. Its educational value lies in a recurring cycle of real problems, research translation, multi-source feedback, and clinical reinterpretation. This framework may inform the design, evaluation, and contextual adaptation of clinical-research integration pathways in medical education.