Academic Intelligence · Curated Daily

Explore the Frontier of Global Academia

AcademicHub aggregates real-time literature from top journals and preprint platforms. Build your personal research radar and let large language models compile cross-disciplinary analysis briefings automatically.

01.
arXiv (CS.LG) 2026-06-17

RadSEM: A Finding-by-Finding Metric for Clinical Consistency in Radiology Reports

arXiv:2606.17062v1 Announce Type: cross Abstract: Radiology report evaluation must distinguish clinical compatibility from surface similarity, because negation, laterality, or normal-abnormal polarity can reverse a finding. We propose RadSEM (Radiology Sentence-Level Evaluation Metric), a constrained LLM-assisted metric for reference-based evaluation of radiology Findings. RadSEM rewrites reference and generated reports into ordered atomic finding sentences, each expressing one site-finding proposition. It then performs contradiction-constrained many-to-many matching: incompatible pairs such as "effusion" and "no effusion" receive no credit, while compatible granularity differences can receive partial credit. A deterministic stage weights pairs by part-whole and abnormal-detail relationships, counts unmatched findings, and produces an abnormal-focused weighted F1 score. Thus, the LLM supports structured rewriting and local alignment rather than acting as an opaque judge. We evaluate RadSEM with SSREE, a controlled monotonicity stress test built from 2,448 de-identified reports expanded into five graded corruption levels. RadSEM achieves Kendall tau_b of 0.957, all-pairs concordance of 97.8%, adjacent concordance of 95.0%, and strict five-level ordering for 81.9% of reports, outperforming radiology-specific and general text metrics while avoiding the failure in which polarity-inverted reports regain lexical overlap. On the same SSREE set, RadSEM outperforms the Ref-anchored RadSEM-Alt policy, improving adjacent concordance from 90.7% to 95.0% and strict ordering from 67.2% to 81.9%. On a 599-triplet synonym/antonym subset, RadSEM prefers synonyms in 597 cases (99.67%). These results suggest that explicit finding units, contradiction-aware matching, and abnormal-focused deterministic scoring make report scoring more interpretable and sensitive to clinically meaningful errors. Code is available at https://github.com/jdh-algo/RadSEM.

02.
arXiv (quant-ph) 2026-06-16

Exact Many-body Quantum Dynamics in One-Dimensional Baths via Collective Spins

arXiv:2505.00588v2 Announce Type: replace Abstract: Computing the exact dynamics of many-body quantum systems becomes intractable as system size grows. Here, we present a symmetry-based method that provides an exponential reduction in the complexity of a broad class of such problems $\unicode{x2014}$ qubits coupled to one-dimensional electromagnetic baths. We identify conditions under which partial permutational symmetry emerges and exploit it to group qubits into collective multi-level degrees of freedom, which we term ''superspins.'' These superspins obey a generalized angular momentum algebra, reducing the relevant Hilbert space dimension from exponential to polynomial. Using this framework, we efficiently compute many-body superradiant dynamics in large arrays of qubits coupled to waveguides and ring resonators, showing that $\unicode{x2014}$ unlike in conventional Dicke superradiance $\unicode{x2014}$ the total spin length is not conserved. At long times, dark states become populated. We identify configurations where these states exhibit metrologically useful entanglement. Our approach enables exact treatment of complex dissipative dynamics beyond the fully symmetric limit and provides a rigorous benchmark for approximate numerical methods.

03.
arXiv (CS.CV) 2026-06-12

Comparing Commercial Depth Sensor Accuracy for Medical Applications

Depth estimation has numerous medical and surgical applications. We benchmark four depth sensors on a porcine bone specimen, a porcine belly specimen, and a silicone kidney phantom using stylus-sampled references. These objects contain several real-world challenges, including homogeneous surfaces, specular surfaces, and subsurface scattering. The comparison includes stereo, structured-light, and time-of-flight sensors at a distance of approximately 50 cm. Specifically, the Intel RealSense D405 (Intel RealSense, United States), PMD Flexx2 (pmdtechnologies, Germany), Stereolabs ZED 2i (Stereolabs, France), and Zivid 2M+ 60 (Zivid, Norway) are compared. The Zivid 2M+ 60 performed best across all objects and metrics considered in this work. The ZED ranked second for real tissue, but last on the phantom.

04.
arXiv (CS.AI) 2026-06-16

Interpretation as Linear Transformation: A Cognitive-Geometric Model of Concepts and Meaning

arXiv:2512.09831v2 Announce Type: replace Abstract: This paper develops a geometric framework for modeling concepts, motivation, and influence across cognitively heterogeneous agents. Each agent is represented by a personalized value space, a vector space encoding the internal dimensions through which the agent interprets and evaluates meaning. Evaluative concepts are formalized as structured vectors, abstract beings, whose transmission is mediated by linear interpretation maps. An abstract being survives communication only if it avoids the null spaces of these maps, yielding a structural criterion for intelligibility, miscommunication, and concept death. Within this framework, I show how conceptual distortion, motivational drift, and the limits of mutual understanding arise from purely algebraic constraints. A central result, the No-Null-Space Leadership Condition, characterizes leadership as a property of representational reachability rather than persuasion or authority. More broadly, the model explains how abstract beings can propagate, mutate, or disappear as they traverse diverse cognitive geometries. The account unifies insights from conceptual spaces, social epistemology, and AI value alignment by grounding meaning preservation in structural compatibility rather than shared information or rationality. I argue that this cognitive-geometric perspective clarifies the epistemic boundaries of influence in both human and artificial systems, and offers a general foundation for analyzing conceptual dynamics across heterogeneous agents.

05.
medRxiv (Medicine) 2026-06-12

The Clinical Characteristics and mortality outcomes of Atrial fibrillation complicating Heart failure with reduced ejection fraction: A prospective study from South Africa

Background: A growing burden of cardiovascular risk factors has raised cardiovascular disease-related mortality in Sub-Saharan Africa (SSA), driving higher prevalence of heart failure with reduced ejection fraction (HFrEF) and its complication with atrial fibrillation (AF). No prospective study has examined AF's clinical impact on HFrEF in SSA. Aim: To determine AF prevalence in HFrEF, describe HFrEF-AF clinical characteristics, and determine AF's impact on mortality. Methods: In this prospective observational study at a tertiary hospital in Johannesburg, 136 HFrEF patients were enrolled and categorised as HFrEF- SR (sinus rhythm) or HFrEF-AF. Baseline clinical characteristics and biochemistry were recorded. Comprehensive echocardiography including left atrial strain by 2D speckle-tracking was performed. Median follow-up was 30.6 months. Results: AF was present in 28 patients (21%). The mean age was 58.7 {+/-} 14.9 years (52.9% male) and differed between groups (p < 0.001). Hypertensive heart disease was the leading cause of HFrEF (36%). Compared with SR, HFrEF-AF patients had poorer health status (KCCQ 27 [16-43] vs 45 [32-60], p < 0.001) and lower left atrial strain (26.2 {+/-} 11.3%, p < 0.001). Guideline-directed medical therapy was suboptimal in the AF group: anticoagulation use was higher than SR (60% vs 9.5%, p < 0.001) but overall inadequate; HFrEF-AF patients received lower median doses of carvedilol (15.6 mg vs 25 mg, p = 0.002) and enalapril (10 mg vs 20 mg, p = 0.004), and fewer received spironolactone (50% vs 75.3%, p = 0.013). Survival was significantly lower in HFrEF-AF (0.41 [0.22-0.61]) versus SR (0.73 [0.61-0.82], p < 0.001). Independent predictors of mortality included prior stroke, lower TAPSE and KCCQ, and higher E/e' and heart rate. Conclusion: AF is common among HFrEF patients in this SSA cohort (though lower than in high-income countries) and associates with worse clinical status, suboptimal therapy, and higher mortality.

06.
arXiv (quant-ph) 2026-06-19

Unleashing Emergent Fermions with Rydberg Atom Simulators

arXiv:2606.19444v1 Announce Type: cross Abstract: Rydberg atom simulators, in both analog and digital modes, have attracted significant recent interest due to their versatile geometric reconfigurability. In this work, leveraging this feature, we propose two complementary approaches, one for each mode, to characterize emergent fermions in critical quantum many-body systems. In the analog mode, we assemble the Rydberg atoms in a "developable" (namely, preserving local couplings) Möbius band geometry to realize antiperiodic boundary conditions, where fermionic states reside. Spectroscopic measurement in this sector then reveals universal energy ratios of the bosonic and fermionic states. In the digital mode, we carry out a fermionic version of Kibble-Zurek ramping with a quantum circuit, directly addressing the fermionic scaling form. Reconfigurability allows an exponential speed-up of this task, with an $O(\log L\log\log L)$ circuit-depth overhead. Our work establishes the Rydberg atom simulator as a uniquely powerful platform to attack the notoriously difficult issue of experimentally probing emergent fermions that are nonlocally defined in a bosonic system.

07.
arXiv (quant-ph) 2026-06-15

Quasilinear Equivalence Checking for Detector Error Models

arXiv:2606.14677v1 Announce Type: new Abstract: A Detector Error Model (DEM) is a structured representation of error mechanisms in quantum circuits, which has gained popularity in quantum compilation pipelines for its ability to capture fault-tolerance at a circuit level. It lists error mechanisms as instructions targeting detectors and observables, specifying for each physical fault channel the probability that the fault fires, the detectors it triggers, and the observables it flips. In this paper, we develop an equational theory for DEMs, with its associated categorical semantics. We present a sound, terminating, confluent rewriting system for DEM terms, formulating it as a symmetric monoidal theory (a PROP) over the Giry monad. We prove that every DEM term has a unique normal form, which can be computed efficiently in quasilinear time $O(k|E|\log|E|)$, where $|E|$ is the number of instructions and $k$ bounds the size of a target set. This provides a complete set of invariants (via Tanner graphs) for structural DEM equivalence. We provide the first static decision procedure for DEM equivalence, with rigorous correctness guarantees. It is complete (decides full decoder-equivalence exactly) for non-adaptive quantum error correction (QEC) pipelines, and scales to a sound and applicable decision procedure for partially-adaptive circuits (lattice surgery, distributed QEC, ...) without suffering exponential overhead. We discuss its application to the verification and optimisation of quantum compilers.

08.
medRxiv (Medicine) 2026-06-15

Evaluation of AI-Generated Synthetic Data for Clinical Research in Secondary Cardiovascular Prevention among Dyslipidemia Patients

Background: Access to high-quality clinical data is essential for advancing medical research and developing effective medical statistical and Artificial Intelligence models. However, privacy regulations and logistical barriers often hinder timely access to real-world data. Synthetic data offer a promising solution, preserving the statistical characteristics of original datasets while protecting patient privacy. Objectives: This study investigates the use of synthetic data for secondary cardiovascular prevention in patients with dyslipidemia, using two real-world datasets from Centro Cardiologico Monzino. Methods: Given the high dimensionality and limited sample size of the datasets, we employed a custom generative framework based on Large Language Models (LLMs). Pre-trained LLMs were fine-tuned on original clinical records to synthesize tabular data replicating source-data distributions. Fine-tuning was performed within the Centro Cardiologico Monzino's secure infrastructure to ensure data sovereignty. We evaluate clinical utility and privacy using fidelity and privacy metrics, identifying the optimal generative model and benchmarking against traditional anonymization methods. Results: Synthetic data achieved a superior trade-off than classically anonymized datasets. Real and synthetic datasets showed strong agreement, with significant distributional differences limited to few variables. Models trained on synthetic data replicated key associations from the original dataset, including therapy modification and creatine phosphokinase as predictors of SAMS, and pharmacological intensity as the main driver of LDL-C reduction. Conclusions: Results support the feasibility of using synthetic data as a proxy for real-world datasets in exploratory analyses and model development. Despite slight attenuation of some effect sizes, preserved clinical relationships reinforce the validity of synthetic data in medical research.

09.
arXiv (CS.LG) 2026-06-19

Data Bias Mitigation under Coverage Constraints & The Price of Fairness

arXiv:2606.20461v1 Announce Type: new Abstract: Machine learning models have been shown to exhibit discriminatory outcomes or degraded performance for individuals at the intersection of multiple sensitive attributes, such as race and gender. This stems in part from two interrelated challenges: the lack of principled measures for quantifying bias (potentially intersectional), and insufficient representation of intersectional subgroups in training data. We extend a recent bias mitigation framework to incorporate coverage constraints that enforce sufficient representation across groups, including intersectional subgroups. Since achieving exactly zero bias for all groups may not be data efficient (meaning it may require large amounts of data), our solution trades small approximation errors in bias for greater data efficiency while satisfying coverage constraints. We also formulate bias mitigation as an integer linear program that optimizes over all mitigation strategies, and characterize the price of fairness, the minimum data modification cost, as a function of fairness tolerance. This is essential both for legal compliance, where regulations may mandate specific fairness thresholds, and for data governance, enabling practitioners to make informed trade-offs between bias reduction and data modification (particularly, data purchasing) costs. We evaluate our techniques on publicly available datasets, demonstrating that bias mitigation via our framework preserves predictive accuracy across multiple classifiers, and that coverage constraints, while motivated by statistical considerations, are essential for preserving downstream ML performance.

10.
arXiv (CS.CV) 2026-06-19

Prediction of Alzheimer's Disease Risk Factors from Retinal Images via Deep Learning: Development and Validation of Biologically Relevant Morphological Associations in the UK Biobank

The systemic, metabolic, lifestyle factors have established associations with Alzheimer's Disease (AD) through epidemiologic and AD-specific biomarker studies. Whether colored fundus photography (CFP) contains retinal structural signatures corresponding to these AD-related risk domains remains unclear. To determine whether deep learning (DL) models can predict 12 AD-related risk factors from CFP and to characterize the retinal structures underlying these predictions, thereby assessing whether CFP reflects pathways to AD vulnerability. Using 62,876 CFPs from 44,501 unique participants from the UK Biobank, DL models were trained to predict 12 factors linked to AD incidence: 6 categorical (sex, smoking, sleeplessness, economic status, alcohol use, depression) and 6 continuous (age, age at completing education, BMI, systolic, diastolic blood pressure, HbA1c). Model performance, model saliency, and saliency-derived scores (CAM-Score) were evaluated and compared to retinal morphometry. The scores were also compared between incident-AD cases (average 8.55 years before onset) and matched controls. Performance of DL ranged from AUROC= 0.5654-0.9480 for categorical and R2=-0.0291-0.7620 for continuous factors, outperforming most of the morphometry-machine learning models. Saliency-based score consistently highlighted biologically meaningful regions, particularly the optic nerve head and retinal vasculature. It also aligned with present morphometric variations. Several saliency-based scores differed significantly between incident AD and matched controls, suggesting potential overlap between retinal correlates of risk factors and preclinical AD-associated changes. CFP encodes retinal signatures linked to AD risk factors. Although not diagnostic, DL-derived retinal representations may uncover biologically meaningful risk-related structural changes mirroring the potential AD vulnerability.

11.
arXiv (CS.CL) 2026-06-15

AdaSR: Adaptive Streaming Reasoning with Hierarchical Relative Policy Optimization

Large reasoning models typically follow a read-then-think paradigm: they observe the complete input, reason over a static context, and then produce the answer. Yet many real-world scenarios are inherently dynamic, such as audio and video stream, where information arrives as a continuous stream and models must reason, update, and respond under partial observations. Recent streaming reasoning methods allow models to think while reading, but they largely rely on supervised imitation of pre-constructed trajectories, which limits their flexibility. In this paper, we propose AdaSR, an adaptive streaming reasoning framework that enables models to reason during input streaming and perform final deliberation once the stream is complete, learning when to think, and how much computation to allocate across different stages. To optimize this hierarchical reasoning process, we introduce Hierarchical Relative Policy Optimization (HRPO), which decomposes policy optimization into streaming reasoning and deep reasoning phases, providing more fine-grained advantage assignment instead of uniformly distributing a single sequence-level advantage over all tokens. HRPO integrates format, accuracy, and adaptive thinking rewards to enforce valid reasoning protocols, preserve final task performance, and encourage latency-aware computation allocation. Experiments show that AdaSR achieves a better balance among reasoning accuracy, computational efficiency, and streaming latency compared with supervised fine-tuning baseline. We release our code at https://github.com/EIT-NLP/StreamingLLM/tree/main/AdaSR.

12.
medRxiv (Medicine) 2026-06-12

A Machine Learning Pipeline for Scalable Annotation of Patient-Ventilator Dyssynchrony from Bedside Ventilator Data

Objective: Patient-ventilator dyssynchrony (PVD) is a common and clinically consequential problem in critically ill patients receiving invasive mechanical ventilation. Yet automated identification of PVD subtypes at scale remains an unmet clinical need, owing to the lack of large annotated bedside waveform datasets. Methods: We developed and validated a semi-supervised algorithm for automated annotation of PVD. In two medical ICUs at a tertiary academic center, bedside devices continuously collected airway flow and pressure waveforms from the ventilators. We developed a software interface with an information retrieval system that grouped similar breaths for expert human review, yielding 1,542,296 labeled breaths across eight categories: 2 labels for breath delivery mode, 5 labels for PVD subtypes, and 1 label denoting a normal breath. Two pulmonary physicians with expertise in ventilator training and education provided the expert reference labels. We trained an initial classification model on a model-derivation set of 771,148 breaths (divided into training and validation) and evaluated it on a hold-out test set of 771,149 breaths A semi-supervised approach was utilized to extend labeling to an additional 12,965,000 unlabeled breaths. Results: The supervised model performed well across all labels, with Macro-F1 scores between 0.96 and 1.00. Semi-supervised learning across 12 rounds expanded the training set from 771,148 to 8,563,995 breaths without significant performance degradation. Conclusion: We developed a practical and scalable system for automated PVD annotation that performed well across all subtypes. This work provides a reproducible foundation for automated PVD labeling to support the development of machine-learning-based clinical decision support systems for identifying patient-level asynchrony.

13.
arXiv (CS.LG) 2026-06-17

Dropout Neural Network Training Viewed from a Percolation Perspective

arXiv:2512.13853v2 Announce Type: replace Abstract: In this work, we investigate the existence and effect of percolation in training deep Neural Networks (NNs) with dropout. Dropout methods are regularisation techniques for training NNs, first introduced by G. Hinton et al. (2012). These methods temporarily remove connections in the NN, randomly at each stage of training, and update the remaining subnetwork with Stochastic Gradient Descent (SGD). The process of removing connections from a network at random is similar to percolation, a paradigm model of statistical physics. If dropout were to remove enough connections such that there is no path between the input and output of the NN, then the NN could not make predictions informed by the data. We study new percolation models that mimic dropout in NNs and characterise the relationship between network topology and this path problem. The theory shows the existence of a percolative effect in dropout. We also show that this percolative effect can cause a breakdown when training NNs without biases with dropout; and we argue heuristically that this breakdown extends to NNs with biases.

14.
arXiv (CS.AI) 2026-06-16

JADE: Expert-Grounded Dynamic Evaluation for Open-Ended Professional Tasks

arXiv:2602.06486v2 Announce Type: replace Abstract: Evaluating agentic AI on open-ended professional tasks faces a fundamental dilemma between rigor and flexibility. Static rubrics provide rigorous, reproducible assessment but fail to accommodate diverse valid response strategies, while LLM-as-a-judge approaches adapt to individual responses yet suffer from instability and bias. Human experts address this dilemma by combining domain-grounded principles with dynamic, claim-level assessment. Inspired by this process, we propose JADE, a two-layer evaluation framework. Layer 1 encodes expert knowledge as a predefined set of evaluation skills, providing stable evaluation criteria. Layer 2 performs report-specific, claim-level evaluation to flexibly assess diverse reasoning strategies, with evidence-dependency gating to invalidate conclusions built on refuted claims. Experiments on BizBench show that JADE improves evaluation stability and reveals critical agent failure modes missed by holistic LLM-based evaluators. We further demonstrate strong alignment with expert-authored rubrics and effective transfer to HealthBench and DR.BENCH, covering medical and 10-domain professional evaluation settings. Code and data are available at https://github.com/smiling-world/JADE.

15.
arXiv (CS.CV) 2026-06-15

Optimizing Rank for High-Fidelity Implicit Neural Representations

Implicit Neural Representations (INRs) based on vanilla Multi-Layer Perceptrons (MLPs) are widely believed to be incapable of representing high-frequency content. This has directed research efforts towards architectural interventions, such as coordinate embeddings or specialized activation functions, to represent high-frequency signals. In this paper, we challenge the notion that the low-frequency bias of vanilla MLPs is an intrinsic, architectural limitation to learn high-frequency content, but instead a symptom of stable rank degradation during training. We empirically demonstrate that regulating the network's rank during training substantially improves the fidelity of the learned signal, rendering even simple MLP architectures expressive. Extensive experiments show that using optimizers like Muon, with high-rank, near-orthogonal updates, consistently enhances INR architectures even beyond simple ReLU MLPs. These substantial improvements hold across a diverse range of domains, including natural and medical images and novel view synthesis, with up to +9 dB PSNR over the same architecture. Code is available at (https://rank-inrs.github.io).

16.
arXiv (quant-ph) 2026-06-15

Certification of the genuine resolution of photon number resolving detectors

arXiv:2606.14365v1 Announce Type: new Abstract: Photon-number-resolving (PNR) detectors are essential components of photonic quantum technologies, yet thus far, no practical metric exists to certify how many photons they can genuinely resolve in a single measurement. Here we introduce an operational framework for quantifying the capability of a PNR detector to distinguish between different numbers of photons, i.e. its genuine resolution. In turn, we develop a practical and scalable protocol for certifying the genuine resolution of a detector, which is based on coherent state probes. We apply the method to a 28-pixel photon-number-resolving superconducting nanowire single-photon detector (PNR-SNSPD) and certify genuine four-outcome resolution. Our work highlights the critical requirements in terms of detector efficiency towards achieving high genuine resolution. This approach provides an operational benchmark for PNR detectors and fills a crucial gap in the characterization of photonic quantum devices.

17.
arXiv (CS.LG) 2026-06-18

Predicting the Neutrino Mass Ordering Using Neural Networks

arXiv:2606.03745v1 Announce Type: cross Abstract: Determining the neutrino mass ordering remains a central open problem in particle physics. While next-generation long-baseline experiments are expected to resolve this question, current data provide limited sensitivity because the spectral differences between normal and inverted ordering are subtle and entangled with parameter degeneracies. We investigate a machine-learning strategy for mass-ordering determination using a feed-forward neural-network classifier trained on synthetic long-baseline datasets generated with three-flavour oscillation probabilities, matter effects, and statistical fluctuations. We evaluate the classifier against standard $\chi^2$ and $\log\mathcal{L}$ approaches using common discrimination metrics, including receiver-operating-characteristic curves, to quantify sensitivity and to illustrate how operating points can be selected to prioritise purity or efficiency. We find that the neural network achieves performance comparable to conventional fits for the scenarios studied, providing a flexible, independent cross-check of established analyses. The framework can be extended to incorporate systematic uncertainties and to explore joint inference of oscillation parameters, and it may also serve as a pedagogical tool for introducing machine-learning methods in neutrino physics.

18.
arXiv (CS.LG) 2026-06-15

Online Convex Optimization with Sublinear Noisy Probes

arXiv:2606.14640v1 Announce Type: new Abstract: We study Online Convex Optimization (OCO) over a convex set $K\subseteq \mathbb R^d$, where in each round $t$ the learner selects $x_t\in K$ and then observes a convex loss $f_t:K\to[0,1]$, with the goal of minimizing regret to the best fixed decision in hindsight. We introduce a unified probing model that generalizes two recent lines of work: sublinear best-expert queries in the experts setting, and pairwise (comparison-based) feedback available every round in OCO. In our framework, the learner has a budget of $k\le T$ pairwise probes; on a probed round it may query two points and learn which one has smaller loss. Our main result shows that even a sublinear and noisy probe budget can provably improve worst-case regret in the full feedback OCO regime. With $k$ $\delta$-noisy pairwise probes, we obtain: $ Reg_T \le O\left(\min\left\{\sqrt{dT\ln T},\; \frac{dT\ln T}{k|1-2\delta|}\right\}\right) $, which is tight (up to logarithmic factors in $T$) across $T$, $k$ and $\delta$. Specifically regarding the noise parameter $\delta \in [0,1]$, the regret guarantee smoothly degrades as the oracle response approaches a coin flip, i.e., $\delta$ is close to $\frac{1}{2}$. When applying the same techniques to a finite $K$ for the prediction with $d$ experts setting, the resulting rates are instead completely tight in all parameters, including $d$. Our analysis gives a streamlined treatment of pairwise probing in OCO by quantifying the benefit of probing via a variance reduction effect, combined with a second-order (variance-based) analysis of Continuous Exponential Weights.

19.
medRxiv (Medicine) 2026-06-22

A blinded, counterbalanced rater design for evaluating AI-assisted summarisation of tertiary clinical genomics reports: methodology of the QNOMX-VHIR-CPSP-001 Phase 1 study

Background. Tertiary clinical genomics reports condense layered molecular findings into documents that treating oncologists must read, translate, and act upon; manual summarisation of these reports is time-consuming and variable. Tools that assist summarisation and translation into local languages are emerging, yet the field lacks an agreed methodology for evaluating such tools before any downstream clinical use. The appropriate first endpoint is fidelity of the generated summary to its source report, assessed by qualified human raters under blinded scoring, not downstream variant classification. Methods. QNOMX-VHIR-CPSP-001 Phase 1 is a single-site, non-interventional clinical performance study conducted at Vall d'Hebron Institut de Recerca (VHIR) under ISO 20916:2019 as a Clinical Performance Study Protocol. De-identified tertiary cancer genomics reports from pediatric oncology cases are summarised by the AI-assisted summarisation system under evaluation and, in parallel, by the standard manual workflow. Qualified raters score both summary types against the source genomics report using the Quality Summary Index (QSI), a six-dimension, five-point rubric adapted from the Provider Documentation Summarization Quality Instrument, under a blinded, counterbalanced, two-period crossover with a minimum fourteen-day washout. Two co-primary composite endpoints, content and presentation, are analysed for non-inferiority under a Bayesian hierarchical model, with a frequentist linear mixed model as the convergence check. Inter-rater reliability is reported as Krippendorff's ; a Monte-Carlo power analysis of the fixed clustered design is pre-specified. Discussion. The design isolates summarisation quality from clinical decision-making by scoring both summary types against the same source report under blinding, counterbalancing, and a fourteen-day washout. Conclusion. The QSI rubric, the counterbalanced crossover, and the pre-specified Bayesian primary with frequentist convergence check define a replicable protocol for early-stage evaluation of AI-assisted summarisation in tertiary genomics reporting; observed variance components will inform sample-size determination for Phase 2.

20.
arXiv (CS.CL) 2026-06-11

Fanar-Sadiq: A Multi-Agent Architecture for Grounded Islamic QA

Large language models (LLMs) can answer religious knowledge queries fluently, yet they often hallucinate and misattribute sources, which is especially consequential in Islamic settings where users expect grounding in canonical texts (Qur'an and Hadith) and jurisprudential (fiqh) nuance. Retrieval-augmented generation (RAG) improves grounding, however, a single retrieve-then-generate pipeline is insufficient for diverse Islamic queries, including verbatim scripture, citation-grounded guidance, and rule-constrained computations such as zakat and inheritance. To address these challenges, we present Fanar-Sadiq, a bilingual Arabic-English Islamic QA system built on a multi-agent, tool-augmented architecture. It is a core component of the Fanar AI platform. Fanar-Sadiq routes Islamic queries to specialized modules within an agentic tool architecture. It supports intent-aware routing, retrieval-grounded fiqh answers with normalized citations and verification traces, exact verse lookup with quotation validation, and deterministic Sunni zakat and inheritance calculators with madhhab-sensitive branching. We evaluate the end-to-end system on public Islamic QA benchmarks and show strong effectiveness and efficiency. It is publicly accessible through an API and Web application and has received over 1.9M accesses in less than a year (https://api.fanar.qa/docs).

22.
arXiv (CS.LG) 2026-06-11

Phase Transitions in Attention: A Bayesian Theory of Copy Head Emergence

arXiv:2606.12058v1 Announce Type: cross Abstract: Attention is the key mechanism underlying in-context learning in transformers, and attention patterns have been observed empirically to emerge abruptly during training. We present a Bayesian theory of feature learning in attention; we then focus on how the copy subcircuit in the first layer of an induction head is learned by analyzing a single-layer softmax attention network trained on a copy task. We derive a closed-form posterior over the attention matrix and reduce it to a low-dimensional order parameter space. This reduction reveals a phase transition in the amount of training data, which we verify using both Bayesian sampling and standard training with Adam. We contrast our results with linear attention and find that softmax attention exhibits a first-order phase transition while in linear attention an initial second-order phase transition is followed by a smooth, continuous evolution toward the structured attention pattern (crossover). Our work provides a first-principles theoretical account of the abrupt emergence of the copy subcircuit, reminiscent of the one observed in training large language models.

23.
arXiv (CS.CL) 2026-06-18

ScholarSum: Student-Teacher Abstractive Summarization via Knowledge Graph Reasoning and Reflective Refinement

Abstractive summarization plays a crucial role in enabling efficient understanding of scientific literature, yet it inherently demands both linguistic fluency and factual faithfulness. Existing approaches often fail to reconcile these two requirements. Extractive methods rely on rigid sentence splicing that disrupts macro-level logical coherence, while large language model (LLM)-based generative approaches, despite mastering linguistic fluency, exhibit limited factual consistency. In this work, we propose ScholarSum, a hierarchical reflective graph-based framework that emulates a student-teacher writing process for fluent and faithful scientific summarization. ScholarSum first organizes the document into a hierarchical knowledge graph by segmenting it into semantically coherent units, whose multi-layered community structure captures global logic and macro-level themes. Guided by this global structure, the student generates an initial draft, which is subsequently refined through fine-grained evidence retrieval. To ensure factual consistency, a teacher-like reviewer then iteratively examines the draft, identifies unsupported content, and prompts targeted re-retrieval and rewriting until the summary meets rigorous quality standards. Extensive experiments demonstrate that ScholarSum significantly outperforms previous baselines in terms of both completeness and faithfulness. Our code is available at https://github.com/Xiaoyu-Tao/ScholarSum.

24.
medRxiv (Medicine) 2026-06-17

Real-World Effectiveness and Safety of Avacopan in ANCA-Associated Vasculitis: A Systematic Literature Review and Meta-analysis

Background: The efficacy and safety of avacopan in ANCA-associated vasculitis (AAV) has been established in randomized trials of of avacopan as a glucocorticoid (GC) sparing therapy. However, real world evidence (RWE) has an important role in confirming effectiveness and evaluating safety in more generalizable settings. This study aimed to synthesize RWE on the effectiveness and safety of avacopan in adults with AAV. Methods: A systematic literature review and meta analysis of non interventional real world studies was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta Analyses (PRISMA) guidelines. Eligible studies included adults with AAV treated with avacopan in routine clinical practice. Pooled estimates of effectiveness and safety outcomes were calculated using random effects meta-analyses. Primary outcomes included remission at 6 and 12 months and sustained remission at 12 months. Secondary outcomes included relapse, GC use and dosing, hepatotoxicity, infections, and treatment discontinuation. Exploratory outcomes included changes in estimated glomerular filtration rate (eGFR) and dialysis related endpoints. Results: A total of 71 studies were included and contributed to quantitative analyses. Pooled remission for patients on avacopan was 87% (95% CI: 75%-94%) at 6 months and 93% (95% CI: 86%-97%) at 12 months, and sustained remission was 86% (95% CI: 74%-93%) at 12 months. Relapse at 12 months was low (7%; 95% CI: 4%-11%). GC use was 36% at both 6 and 12 months. Improvements in eGFR were observed at 6 months (18 mL/min/1.73 m2) and 12 months (18 mL/min/1.73 m2), and dialysis liberation was 66% in a limited subset. Among avacopan patients, 11% experienced any hepatotoxicity, including 7% with serious (defined as directly reported or requiring hospitalization) hepatotoxicity, while 7% experienced serious (defined as directly reported or requiring hospitalization) infection. Conclusions: In real world clinical practice, avacopan is associated with high remission rates, low relapse rates, and a consistent GC sparing effect, with effectiveness comparable to standard of care regimens. Findings support its clinical use with appropriate safety monitoring; however, the observed heterogeneity in hepatotoxicity and the limited comparative effectiveness evidence highlight areas requiring further investigation.

25.
bioRxiv (Bioinfo) 2026-06-10

Folding the unfoldable 2: using AlphaFold and ESMFold to explore spurious proteins

Motivation: Spurious protein sequences, resulting from gene prediction errors, theoretically should not yield folded structures. AlphaFold2 was previously shown to predict short spurious sequences with high pLDDT scores and was therefore unlikely to distinguish between real proteins and spurious proteins which are usually short. We evaluate whether newer structure prediction methods (ESMFold and AlphaFold3) similarly predict short sequences with high pLDDT or if they better discriminate between spurious and real proteins. Results: All three structure prediction methods (ESMFold, AlphaFold2, and AlphaFold3) predict short spurious sequences from AntiFam with unexpectedly high pLDDT scores, however the discrimination between spurious and real proteins improves beyond 100 amino acids. By analysing sequences with disparate pTM and pLDDT scores, we identified two likely spurious shadow ORFs in Swiss-Prot and one potentially non-spurious AntiFam entry. Using the structure prediction scores, we developed a Gaussian Process Model and evaluated its performance on AlphaFold DB, identifying potential spurious proteins at scale. While limited on its own, this model can increase confidence in spurious protein identification when combined with other methods.