×

Academic Intelligence · Curated Daily

Explore the Frontier of Global Academia

AcademicHub aggregates real-time literature from top journals and preprint platforms. Build your personal research radar and let large language models compile cross-disciplinary analysis briefings automatically.

Authors: Theis ×
Shuffle
01.
medRxiv (Medicine) 2026-06-15

Validating Field-Feasible Measures of Recent Khat Use: A Diagnostic Accuracy Study Comparing Amphetamine Immunoassay and Assisted Self-Report Against HPLC in an Ethiopian Male Cohort

Background: Khat (Catha edulis) is a widely consumed natural amphetamine-analog used across East Africa and the Arabian Peninsula. Accurate field-feasible measurement of recent khat use is a prerequisite for large-scale epidemiological research; yet no validated alternatives to laboratory reference methods have been identified in the scientific literature. This nested validation study evaluated the diagnostic accuracy of two point-of-care measures, a commercial amphetamine immunoassay and a Timeline Followback (TLFB) Assisted Self-Report (ASR), against high-performance liquid chromatography (HPLC) quantification of urinary norephedrine (NE), while additionally assessing agreement between the two field measures. Methods: A prospective, random sub-sample of 119 male participants aged 18-40 years from the Gilgel Gibe Field Research Center (GGFRC) longitudinal cohort, Ethiopia (validation timepoint T2, 2015), was used. Three index-reference comparisons were conducted: (1) amphetamine immunoassay (nal von minden, Drug-Screen AMP test, 300 ng/mL cutoff) vs. HPLC; (2) binary ASR (past-week use) vs. HPLC; and (3) binary ASR vs. immunoassay. Sensitivity (positive percent agreement, PPA), specificity (negative percent agreement, NPA), positive predictive value (PPV), negative predictive value (NPV), overall accuracy (overall percent agreement, OPA), and Cohen's kappa were calculated with 95% confidence intervals. Pre-specified secondary analyses applied three pharmacokinetically-informed recall windows (0-2, 3-5, and 6-7 days prior to interview) to ASR. Results: Against HPLC (77 positive, 42 negative), the immunoassay showed perfect specificity (1.0 [0.916-1.0]) and PPV (1.0 [0.91-1.0]) but low sensitivity (0.52 [0.40-0.64]), NPV (0.53 [0.42-0.65]), overall accuracy (0.69 [0.60-0.77]), and weak kappa (0.43 [0.34-0.52]). Binary ASR showed high sensitivity (0.96 [0.89-0.99]), specificity of 0.60 [0.433-0.74], PPV (0.81 [0.72-0.89]), NPV (0.89 [0.72-0.98]), with overall accuracy 0.83 [0.75-0.89] and moderate kappa (0.60 [0.51,0.69]). Restricting ASR to use within 0-2 days improved specificity to 0.69 [0.52-0.84], PPV to 0.86 [0.77-0.93], overall accuracy to 0.87 [0.79-0.93], and kappa to 0.69 [0.61-0.78] (moderate), while sensitivity (0.96 [0.89-0.99]) and NPV (0.89 [0.72-0.98]) remained stable. Against the immunoassay, ASR achieved high PPA of (1.0 [0.91-1.0]), NPA of 0.35 [0.25-0.47], OPA of 0.57 [0.48-0.66], and minimal kappa (0.27 [0.19-0.35]). Conclusions: Time-stratified ASR (0-2 days) is a valid, scalable alternative to biological testing for recent khat use in resource-limited settings. The immunoassay's 300 ng/mL cutoff functions as a marker of heavy or recent high-dose khat use rather than any-use detection. Its perfect specificity and PPV make it valuable as a confirmatory test for substantial exposure, while its lower sensitivity reflects calibration to amphetamine rather than to khat-derived cathinone metabolite. Keywords: khat; Catha edulis; diagnostic accuracy; STARD; self-report; immunoassay; HPLC; Ethiopia; substance use measurement

02.
medRxiv (Medicine) 2026-06-17

Targeted Proteomic Profiling of Nasal Fluid from the Brain-Nose Interface

The brain-nose interface is an anatomical junction where olfactory neurons from the olfactory bulb traverse the cribriform plate into the nasal mucosa, providing minimally invasive access to the central nervous system (CNS). We hypothesized that nasal fluid from this region could enable detection of neurology-relevant proteins using targeted multiplex assays. Using nosecollect, a targeted nasal sampling device, nasal fluid proximal to brain-nose interface was collected from cognitively impaired patients, alongside matched cerebrospinal fluid (CSF) and plasma. After nasal sample-specific dilution optimization and intra-assay precision evaluation, all matrices were profiled with the Olink Target 96 Neurology and NUcleic acid Linked Immuno-Sandwich Assay CNS disease 120 (NULISAseq CNS Disease 120) panels. Nasal fluid showed technically repeatable detection (intra-assay coefficient of variation

03.
bioRxiv (Bioinfo) 2026-06-18

Benchmarking gene expression reconstruction from single-cell latent representations

Single-cell transcriptomics is typically modeled in low-dimensional latent representations that improve the signal-to-noise ratio of the data. Such representations underpin data integration, cell state discovery, and perturbation prediction, with applications ranging from large-scale organ atlases to latent trajectory modeling. Recent virtual cell approaches further leverage these representations to predict cellular responses as distributional shifts in latent space. Each of these applications ultimately requires faithful gene expression reconstruction from latent spaces for biological interpretation, enabling gene-level analysis of predicted perturbed or batch-corrected cells. Yet representation choice is typically treated as an implementation detail rather than a primary modeling decision, with no systematic evaluation of how well latent representations support gene expression reconstruction. Here, we introduce ReconEval, a benchmark for evaluating gene expression reconstruction from single-cell latent spaces. We benchmark two classes of latent representations: end-to-end trained models such as PCA, autoencoders, and variational autoencoders, and pretrained single-cell foundation model embeddings coupled to newly trained decoders. Reconstruction is evaluated both directly and after latent-space perturbation prediction. Across perturbational and observational datasets totaling over 100 million cells, our metric suite quantifies statistical fidelity; biological signal preservation, including differential expression, coexpression, cell-cycle structure, cytokine response and pathway activity; and perturbation-specific effects. We find that autoencoders achieve the strongest stand-alone reconstruction at low dimensionality, while variational regularization does not improve generalization in reconstruction. Frozen foundation model embeddings retain recoverable gene-level information, with reconstruction quality depending strongly on decoder architecture and pretraining objective. In latent perturbation modeling, high-dimensional PCA matches foundation model embeddings, while low-dimensional AE embeddings are optimal for flow-based generative models. Overall, reconstruction depends critically on the interplay between representation and downstream model, and simpler representations can outperform complex alternatives given appropriate capacity. Our benchmark establishes reconstruction as a critical evaluation axis for single-cell foundation models. We envision it improving the biological interpretability of latent-space modeling, a prerequisite for future virtual cell models to be validated by domain experts and grounded in biology.

04.
arXiv (CS.AI) 2026-06-25

OmegAMP: Targeted AMP Discovery via Biologically Informed Generation

arXiv:2504.17247v3 Announce Type: replace-cross Abstract: Deep learning-based antimicrobial peptide (AMP) discovery faces critical challenges such as limited controllability, lack of representations that efficiently model antimicrobial properties, and low experimental hit rates. To address these challenges, we introduce OmegAMP, a framework designed for reliable AMP generation with increased controllability. Its diffusion-based generative model leverages a novel conditioning mechanism to achieve fine-grained control over desired physicochemical properties and to direct generation towards specific activity profiles, including species-specific effectiveness. This is further enhanced by a biologically informed encoding space that significantly improves overall generative performance. Complementing these generative capabilities, OmegAMP leverages a novel synthetic data augmentation strategy to train classifiers for AMP filtering, drastically reducing false positive rates and thereby increasing the likelihood of experimental success. Our in silico experiments demonstrate that OmegAMP delivers state-of-the-art performance across key stages of the AMP discovery pipeline, enabling us to achieve an unprecedented success rate in wet lab experiments. We tested 25 candidate peptides, 24 of them (96%) demonstrated antimicrobial activity, proving effective even against multi-drug resistant strains. Our findings underscore OmegAMP's potential to significantly advance computational frameworks in the fight against antimicrobial resistance.