×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Stewart ×
换一批
01.
arXiv (CS.CL) 2026-06-16

Nemotron 3 Ultra: Open, Efficient Mixture-of-Experts Hybrid Mamba-Transformer Model for Agentic Reasoning

We introduce Nemotron 3 Ultra, a 550 billion total and 55 billion active parameter Mixture-of-Experts Hybrid Mamba-Attention language model. We pre-trained Nemotron 3 Ultra on 20 trillion text tokens, then extended the context length to 1M tokens, and post-trained using Supervised Fine Tuning (SFT), Reinforcement Learning (RL), and Multi-teacher On-Policy Distillation (MOPD). Nemotron 3 Ultra is our most capable model yet, employing multiple key technologies - LatentMoE, Multi Token Prediction (MTP), NVFP4 pre-training, multi-environment RLVR, MOPD, and reasoning budget control. Nemotron 3 Ultra achieves up to ~6x higher inference throughput as compared to state-of-the-art publicly available LLMs while attaining on-par accuracy. The state-of-the-art accuracy, high inference throughput, and 1M token context length make Nemotron 3 Ultra ideal for long-running autonomous agentic tasks. We open-source the base, post-trained, and quantized checkpoints, along with the training data and recipe on HuggingFace.

02.
medRxiv (Medicine) 2026-06-15

Validating Field-Feasible Measures of Recent Khat Use: A Diagnostic Accuracy Study Comparing Amphetamine Immunoassay and Assisted Self-Report Against HPLC in an Ethiopian Male Cohort

Background: Khat (Catha edulis) is a widely consumed natural amphetamine-analog used across East Africa and the Arabian Peninsula. Accurate field-feasible measurement of recent khat use is a prerequisite for large-scale epidemiological research; yet no validated alternatives to laboratory reference methods have been identified in the scientific literature. This nested validation study evaluated the diagnostic accuracy of two point-of-care measures, a commercial amphetamine immunoassay and a Timeline Followback (TLFB) Assisted Self-Report (ASR), against high-performance liquid chromatography (HPLC) quantification of urinary norephedrine (NE), while additionally assessing agreement between the two field measures. Methods: A prospective, random sub-sample of 119 male participants aged 18-40 years from the Gilgel Gibe Field Research Center (GGFRC) longitudinal cohort, Ethiopia (validation timepoint T2, 2015), was used. Three index-reference comparisons were conducted: (1) amphetamine immunoassay (nal von minden, Drug-Screen AMP test, 300 ng/mL cutoff) vs. HPLC; (2) binary ASR (past-week use) vs. HPLC; and (3) binary ASR vs. immunoassay. Sensitivity (positive percent agreement, PPA), specificity (negative percent agreement, NPA), positive predictive value (PPV), negative predictive value (NPV), overall accuracy (overall percent agreement, OPA), and Cohen's kappa were calculated with 95% confidence intervals. Pre-specified secondary analyses applied three pharmacokinetically-informed recall windows (0-2, 3-5, and 6-7 days prior to interview) to ASR. Results: Against HPLC (77 positive, 42 negative), the immunoassay showed perfect specificity (1.0 [0.916-1.0]) and PPV (1.0 [0.91-1.0]) but low sensitivity (0.52 [0.40-0.64]), NPV (0.53 [0.42-0.65]), overall accuracy (0.69 [0.60-0.77]), and weak kappa (0.43 [0.34-0.52]). Binary ASR showed high sensitivity (0.96 [0.89-0.99]), specificity of 0.60 [0.433-0.74], PPV (0.81 [0.72-0.89]), NPV (0.89 [0.72-0.98]), with overall accuracy 0.83 [0.75-0.89] and moderate kappa (0.60 [0.51,0.69]). Restricting ASR to use within 0-2 days improved specificity to 0.69 [0.52-0.84], PPV to 0.86 [0.77-0.93], overall accuracy to 0.87 [0.79-0.93], and kappa to 0.69 [0.61-0.78] (moderate), while sensitivity (0.96 [0.89-0.99]) and NPV (0.89 [0.72-0.98]) remained stable. Against the immunoassay, ASR achieved high PPA of (1.0 [0.91-1.0]), NPA of 0.35 [0.25-0.47], OPA of 0.57 [0.48-0.66], and minimal kappa (0.27 [0.19-0.35]). Conclusions: Time-stratified ASR (0-2 days) is a valid, scalable alternative to biological testing for recent khat use in resource-limited settings. The immunoassay's 300 ng/mL cutoff functions as a marker of heavy or recent high-dose khat use rather than any-use detection. Its perfect specificity and PPV make it valuable as a confirmatory test for substantial exposure, while its lower sensitivity reflects calibration to amphetamine rather than to khat-derived cathinone metabolite. Keywords: khat; Catha edulis; diagnostic accuracy; STARD; self-report; immunoassay; HPLC; Ethiopia; substance use measurement

03.
medRxiv (Medicine) 2026-06-17

Proteomics Uncovers Cryptic JPH2 Loss in Paediatric Dilated Cardiomyopathy

Despite recent advances in next-generation sequencing, genetic diagnostic rates for dilated cardiomyopathy (DCM) remain low. Among paediatric DCM, causes are often heritable, with a greater frequency of de novo, recessive and syndromic causes of disease. Novel diagnostic methods are therefore required to solve monogenic cases. To assess the value of proteomics as a diagnostic tool for paediatric DCM, we obtained left ventricle myocardial samples from paediatric patients undergoing heart transplantation at the Royal Children's Hospital, Melbourne. We performed genome sequencing and proteomics and leveraged this multi-omics dataset to uncover the molecular cause of disease in a gene elusive proband. The proband carried a heterozygous JPH2 frameshift variant identified on clinical exome sequencing. However, proteomic analysis showed a pronounced downregulation of JPH2, suggestive of biallelic loss-of-function. Closer inspection of the genomic data revealed a large inversion (~8.34 Mb) with a breakpoint falling within intron 5 of JPH2 that displaces the 3'UTR from the coding transcript. The two variants were confirmed to be in trans using long read DNA sequencing, consistent with a diagnosis of JPH2 autosomal recessive DCM. Finally, we applied RNA sequencing with total RNA library preparation to show that transcripts containing a 3'UTR were reduced to ~10% relative to controls. As a proof-of-principle, we present the first reported use of proteomics from explanted cardiac tissue to provide a genetic diagnosis. Our methodology has broad relevance to patients with genetically unsolved Mendelian diseases, who might undergo organ transplantation as part of clinical management.