×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Siddharth Panwar ×
换一批
01.
arXiv (CS.LG) 2026-06-11

Anatomy of Post-Training: Using Interpretability to Characterize Data and Shape the Learning Signal

arXiv:2606.12360v1 Announce Type: new Abstract: Language-model post-training is the main stage at which model behavior is shaped, yet it still largely involves optimization of scalar rewards that summarize diverse desiderata. This abstraction gives practitioners little visibility into what their data actually teaches models, allowing spurious correlations to be learned by a model and inducing undesirable behaviors such as over-stylization and sycophancy. To address this problem, we ask: can we inspect a preference dataset before optimization and decide, at the level of concepts, which behaviors a model should be allowed to learn? Motivated by this, we introduce a data-centric post-training pipeline that uses interpretability protocols to develop statistical hypotheses for the latent concepts separating preferred from dispreferred generations, making them explicit for fine-grained user feedback. Building on this view, we unify several interpretability-based training protocols as ways of shaping rewards via feature or data interventions. Empirically, we show that our pipeline diagnoses undesirable signals in existing preference data, mitigates off-target learning, and can also help amplify or shape desired properties such as safeguards and model personality. More broadly, our results suggest that interpretability can turn post-training from optimizing opaque proxy rewards into a process of auditing and sculpting the learning signal itself.

02.
arXiv (CS.LG) 2026-06-16

How Much Capacity Does EEG Denoising Need? Ultra-Compact Networks reveal Benchmark Saturation and Metric-Utility Gap

arXiv:2606.08594v2 Announce Type: replace Abstract: Deep learning EEG denoising architectures have scaled from tens of thousands to tens of millions of parameters, yet no prior study has isolated model capacity as the experimental variable or tested whether reconstruction metrics predict downstream neural-signal utility. We address both gaps by fixing architecture, loss, data split, and training recipe while sweeping only channel width from 1.05K to 40.26K parameters in a minimal depthwise-separable convolutional U-Net. Models were evaluated on the EEGDenoiseNet benchmark, cross-dataset BCI transfer tests, controlled baseline retraining, and downstream motor-imagery classification with five decoder families across all nine BCI Competition IV-2a subjects. Reconstruction performance saturated by 3-6.5K parameters, with post-elbow gains of at most 0.015 correlation coefficient per log10-parameter unit. An 8.46M-parameter baseline retrained under the same pipeline matched the 40.26K compact variant on EOG–a 200x parameter gap yielding no advantage–while a Patch-Transformer control reproduced the same diminishing-return shape. Downstream evaluation exposed a classifier-dependent metric-utility gap: reconstruction-optimized denoising significantly degraded CSP+LDA classification across all nine subjects and three artifact types (best denoised accuracy 0.547 vs. 0.612 noisy baseline; Bonferroni p=0.0488), persisting on naturally recorded trials (Delta=-0.047; BH-FDR q=0.0049). End-to-end neural decoders showed variable or neutral effects. Standard EEG denoising benchmarks are saturated far below current model capacity, and reconstruction metrics do not predict BCI utility. Ultra-compact models at 33-46 KB and 1.27-2.61M FLOPs/segment are practical for edge deployment. These findings argue for capacity-controlled evaluation, harder task-aware benchmarks, and mandatory downstream validation.

03.
arXiv (CS.LG) 2026-06-16

A spectral audit framework reveals task-dependent aperiodic reliance across EEG and ECG deep learning

arXiv:2606.08583v2 Announce Type: replace Abstract: Deep learning on physiological time series is interpreted through domain-specific features – oscillatory rhythms in EEG, morphological complexes in ECG – yet these signals sit atop a broadband aperiodic 1/f-like envelope that covaries with arousal, age, and pathology. We introduce a spectral audit framework combining aperiodic/periodic decomposition, phase-preserving Fourier interventions, sham controls, and simulation validation. Aperiodic reliance was task-dependent and architecture-general: across six neural architectures, flattening drops exceeded 0.42 balanced-accuracy points for sleep-wake classification, reached 0.07-0.13 for clinical abnormality detection, and remained minimal for motor imagery. Six of seven EEG foundation models showed FDR-significant aperiodic reliance on clinical EEG; age/sex and recording-era controls reduced but did not eliminate the effect. Applying the audit to PTB-XL ECG revealed neural drops of 0.32–0.36 persisting after demographic matching, confirming this confound class extends beyond EEG. Aperiodic controls should become standard for interpretable physiological time-series deep learning.