×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: S. H.-C ×
换一批
01.
medRxiv (Medicine) 2026-06-18

A Novel Correction Method for QT Interval in the Presence of Left Bundle Branch Block Morphology

Background Accurate assessment of the QT interval is challenging in the presence of QRS prolongation, such as during ventricular pacing or bundle branch block. Current correction methods are heterogeneous and lack consensus. To evaluate the relationship between QRS duration and QT interval during ventricular pacing and to develop a practical correction method for QT assessment. Methods In this prospective single-centre study, 94 patients undergoing electrophysiology study for supraventricular tachycardia were included. Standardised pacing was performed at the same cycle length from the right ventricular (RV) apex, high output and low output pacing from His catheter, and coronary sinus (reference). QRS and QT intervals were measured from 12-lead ECGs. Changes in QT (QT) and QRS duration (QRS) were analysed using linear regression and mixed-effects modelling. QT correction formulas of the form QT corrected = QT N x QRS were evaluated using Bland-Altman analysis across multiple coefficients. Results A significant positive correlation between QRS and QT was observed across all pacing sites (r = 0.52-0.74, p < 0.001). In mixed-effects modelling, QRS was a strong independent predictor of QT (0.59, p < 0.001), with no significant interaction between pacing site and QRS, supporting a consistent relationship across pacing locations. Bland-Altman analysis demonstrated that correction coefficients of 0.65-0.70 minimised systematic bias compared with lower coefficients, with similar precision across models (SD 16 ms) and no evidence of proportional bias. A coefficient of 0.65 provided the most balanced performance between bias and variability. Conclusion QT prolongation during ventricular pacing is primarily driven by QRS widening and follows a consistent linear relationship across pacing sites. A simple correction using QT corrected = QT 0.65 x (QRS 100 ms) provides a practical and accurate method for QT assessment, with potential clinical applicability in patients with conduction abnormalities or ventricular pacing.

02.
bioRxiv (Bioinfo) 2026-06-17

Correcting spatial transcriptomics data affected by a prevalent transcript leakage problem across platforms, species, and tissues

Spatial transcriptomics has been widely applied to study the spatial distribution of cell types, cell states, and specific gene expression in tissue samples. However, we show that there is a prevalent transcript leakage problem in spatial transcriptomics data, where transcripts expressed by a cell diffuse to its neighborhood and are recurrently detected in the nearby cells. By analyzing published data sets, we show that this problem is general across data produced from different tissues and different species using different imaging-based and sequencing-based spatial transcriptomics platforms. It affects both upstream tasks such as expression quantification as well as downstream tasks such as cell-type annotation and detection of spatially-dependent gene expression. To tackle the transcript leakage problem, we propose a reference-free Bayesian model-based method, DeLeakage, which cleans up the data much more effectively than existing denoising methods. DeLeakage also improves cell-type annotation and avoids false detection of spatially dependent expression.