×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Qianhui Liu ×
换一批
01.
arXiv (CS.CV) 2026-06-25

Evaluation Protocols and Validation for Cameras in Indoor Healthcare Monitoring

Camera-based monitoring systems are increasingly adopted in healthcare settings for the continuous assessment of patient movement and activities. However, their technical performance under real-world indoor conditions remains insufficiently characterised, preventing appropriate camera selection for clinical or home adoption and reproducibility. Existing validation studies typically assess either device metrological performance or algorithm accuracy in isolation, and often do not systematically account for practical deployment factors, such as lighting variability, occlusions, and camera positioning. We present two technical validation protocols: the first evaluates the metrological performance of RGB and RGB-D cameras, and the second assesses their use in supporting human pose estimation, validated using state-of-the-art pose estimators. The proposed protocols systematically assess five cameras, four RGB-D and one RGB, under controlled variations in lighting, camera height, viewing angle, and occlusion level within representative indoor scenarios. The experimental results show that metrological performance varies substantially across cameras, with depth bias at 5 m ranging from 50 mm to over 1400 mm depending on the device. For 2D pose estimation, all cameras achieve broadly comparable accuracy, with mean mAP between approximately 78% and 90% across cameras and estimators, whereas 3D reconstruction error differs markedly across devices, with MPJPE ranging from 104 mm to 365 mm, closely reflecting underlying depth-sensing quality. Environmental factors have a camera- and estimator-dependent effect on 3D performance, while camera mounting height has minimal influence within the evaluated range. This work provides evidence-based guidance for the selection and deployment of cameras in healthcare monitoring applications, addressing an important gap in current technical validation practice.

02.
arXiv (CS.AI) 2026-06-12

Otters++: A Time-to-first-spike Based Energy Efficient Optical Spiking Transformer

arXiv:2606.13016v1 Announce Type: new Abstract: Spiking neural networks (SNNs) are promising for energy-efficient inference, and time-to-first-spike (TTFS) coding is especially attractive because each neuron fires at most once. In practice, however, this benefit is often reduced by the cost of computing a temporal decay term and multiplying it by the synaptic weight. We address this issue by turning a physical hardware "bug," the natural signal decay in optoelectronic devices, into the main computation of TTFS, named Otters++. Specifically, we use the measured decay of a custom In$_2$O$_3$ optoelectronic synapse to directly realize the TTFS temporal term, removing the need for explicit digital decay computation. To scale this idea to Transformer models, we establish a layer-wise functional equivalence between the Otters++ and a quantized neural network (QNN), and develop a hybrid training method that uses device-faithful SNN computation in the forward pass and QNN straight-through gradients through the equivalent QNN path in the backward pass, together with model distillation. This avoids differentiation through discrete first-spike events and reduces the over-sparsity problem in direct TTFS-SNN training. We further make training aware of measured device noise by sampling run-to-run variation, and refine the system-level energy model by accounting for device sharing and multi-hop communication. On GLUE dataset, Otters++ improves the average score to 84.17\% while maintaining a clear energy advantage over prior spiking Transformer baselines. These results show that physically grounded TTFS computing can be efficient, trainable, and robust under realistic hardware effects.