×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Mu He ×
换一批
01.
medRxiv (Medicine) 2026-06-10

Prediction of immunotherapy response using live tumor fragments from routine clinical biopsies

Functional ex vivo assays using live tumor tissues have demonstrated strong predictive accuracy for response to immune checkpoint inhibitors (ICIs) but are not scalable, requiring manual processing of large resections collected at academic centers. Here, an ex vivo live tumor fragment (LTF) platform was developed using standard-of-care biopsies from 228 patients with suspected malignancy collected across prospective, multicenter observational trials and biobanks. Hierarchical clustering of ICI-mediated changes in cytokine production identified two groups: responders and nonresponders. A binary classifier (elive index) using 8 cytokines achieved an AUC of 0.99 for cluster prediction. elive index correctly predicted clinical benefit in 93% (26/28) of patients (P = 3.2x10-5) and accurately identified 83% (10/12) of objective responders. Critically, elive responders were identified among biomarker-negative patients, highlighting the platform as a scalable approach that complements existing companion diagnostics and expands the population of patients identified to benefit from ICI therapy.

02.
arXiv (CS.CL) 2026-06-16

Scaling LLM Reasoning from Minimal Labels: A Semi-Supervised Framework with a Lightweight Verifier

For the development of Large language models (LLMs), recent approaches to generating pseudo intermediate reasoning have shown remarkable progress. But they typically rely on large numbers of correctly annotated answers to assess reasoning quality. This paper presents a semi-supervised framework that scales reasoning learning from minimal supervision, turning reasoning verification itself into a data creation mechanism. We train a lightweight reasoning-correctness classifier on only a few labeled samples, which judges whether intermediate reasoning traces generated by an LLM are valid. Furthermore, an entropy-based confidence threshold filters out unreliable samples, and the remaining high-confidence reasoning traces are used to fine-tune the model. Experiments on Verifiable Math Problems (Orca-Math subset) and Question Answering on Image Scene Graphs (GQA) with Visual Programming show that our method achieves accuracy comparable to using 10-15x more labeled data. Ablation analyses confirm that both the classifier and entropy filtering are essential for scalable and noise-resistant pseudo-labeling. By replacing expensive answer-level supervision with lightweight reasoning verification, our method provides a practical path toward constructing large-scale reasoning resources and paves the way for future autonomous reasoning systems that learn from minimal human input.

03.
arXiv (math.PR) 2026-06-16

Risk-averse mean field games: exploitability and non-asymptotic analysis

arXiv:2301.06930v5 Announce Type: replace-cross Abstract: In this paper, we use mean field games (MFGs) to investigate approximations of $N$-player games ($N$pGs) with uniformly symmetrically continuous heterogeneous closed-loop actions. To incorporate agents' risk aversion (beyond the classical expected utility of total costs), we use an abstract evaluation functional for their performance criteria. Centered around the notion of exploitability, we conduct non-asymptotic analysis on the approximation capability of MFGs from the perspective of state-action distributions without requiring the uniqueness of equilibria. Under suitable assumptions, we first show that scenarios in the $N$pGs with large $N$ and small average exploitabilities can be well approximated by approximate solutions of MFGs with relatively small exploitabilities. We then show that $\delta$-mean field equilibria can be used to construct $\varepsilon$-equilibria in $N$pGs. Furthermore, in this general setting, we prove the existence of mean field equilibria. This proof reveals a possible avenue for incorporating penalization for randomized action into MFGs.

04.
arXiv (CS.AI) 2026-06-11

Privacy-Preserving Federated Autoencoder for ECG Anomaly Detection on Edge Devices

arXiv:2606.11556v1 Announce Type: cross Abstract: Continuous electrocardiography (ECG) monitoring could surface rhythm abnormalities before they escalate into cardiovascular events. However, a deployable system must satisfy three requirements simultaneously: legal-grade privacy (GDPR, HIPAA), real-time inference on constrained edge hardware, and detection quality under non-IID cross-hospital data. We design and evaluate an end-to-end federated system addressing all three for unsupervised 12-lead ECG anomaly detection on PTB-XL dataset, combining three autoencoder families (VanillaAE, ConvAE, VAE), Flower-based federated averaging (FedAvg) across ten simulated hospitals, client-side differentially private SGD (DP-SGD) with a Rényi-DP accountant, and 8-bit integer (INT8) post-training quantization with Raspberry Pi 4 benchmarking. Our main contributions are: an empirical characterization of how these mechanisms compose, practical DP-specific recommendations, and technical and security insights for a clinically sensitive setting. Federated learning matches or exceeds the centralized baseline across all architectures (ConvAE federated area under the ROC curve, AUROC, $0.782$), and an $\varepsilon$ sweep identifies $\varepsilon=4$ as the recommended clinical operating point. INT8 quantization roughly halves model size and cuts Pi 4 latency by up to $44%$ with $

05.
arXiv (CS.CV) 2026-06-12

Transformer-Guided Graph Attention for Direct Cardiac Mesh Reconstruction: A Structural Digital Twin Framework

Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating. The standard workflow – segmenting the image, running Marching Cubes, and then manually cleaning up the result – is time-consuming, inconsistent across operators, and demands specialist knowledge most clinical teams do not have. We take a fundamentally different approach. Instead of treating segmentation and mesh generation as two separate problems, we train a single end-to-end network that goes directly from a raw 3D medical image to a smooth, simulation-ready cardiac surface mesh. The core is a 3D Swin Transformer encoder-decoder that extracts volumetric features from CT or MRI volumes, paired with a Graph Attention Network (GAT) head that iteratively deforms a template mesh to fit the patient's cardiac boundary. We tested on the MM-WHS 2017 benchmark using both CT and MRI. Segmentation scores were competitive (Dice of 0.84 on CT, 0.83 on MRI), but the primary focus is mesh quality: mean Chamfer distance of 1.8 mm, with 95th-percentile surface distance below 5 mm. Every mesh is produced in a single forward pass – no Marching Cubes, no smoothing filters, no manual cleanup. We argue that for cardiac digital twin pipelines, geometric fidelity and topological correctness matter more than pixel-level Dice scores. By removing the post-processing bottleneck, this approach makes patient-specific cardiac simulation substantially more accessible for clinical use.

06.
arXiv (CS.CV) 2026-06-16

MVEB: Massive Video Embedding Benchmark

We introduce the Massive Video Embedding Benchmark (MVEB), a 23-task benchmark for video embeddings spanning classification, zero-shot classification, clustering, pair classification, retrieval, and video-centric question answering. We evaluate 33 models and find that no single model dominates: MLLM-based embeddings lead on classification, clustering, pair classification, and QA; multimodal binding leads on retrieval and zero-shot classification; generative MLLMs without contrastive adaptation collapse on cross-modal tasks. Paired video-only vs. audio+video evaluations show that audio's contribution depends on dataset annotation provenance: audio helps when labels were produced from both modalities and hurts when they were produced from visuals alone, a six-point gap consistent across model families. MVEB is derived from MVEB+, a 184-task pool, and is designed to maintain task diversity while reducing evaluation cost. It integrates into the MTEB ecosystem for unified evaluation across text, image, audio, and video. We release MVEB and all 184 tasks along with code and a leaderboard at https://github.com/embeddings-benchmark/mteb.

07.
arXiv (CS.AI) 2026-06-19

Automated Standardization of Legacy Biomedical Metadata Using an Ontology-Constrained LLM Agent

arXiv:2604.08552v2 Announce Type: replace-cross Abstract: Scientific metadata are often incomplete and noncompliant with community standards, limiting dataset findability, interoperability, and reuse. Even when standard metadata reporting guidelines exist, they typically lack machine-actionable representations. Producing FAIR datasets requires encoding metadata standards as machine-actionable templates with rich field specifications and precise value constraints. Recent work has shown that LLMs guided by field names and ontology constraints can improve metadata standardization, but these approaches treat constraints as static text prompts, relying on the model's training knowledge alone. We present an LLM-based metadata standardization system that queries standard reporting guidelines and authoritative biomedical terminology services in real time to retrieve canonically correct standards on demand. We evaluate this approach on 839 legacy metadata records from the Human BioMolecular Atlas Program (HuBMAP) using an expert-curated gold standard for exact-match assessment. Our evaluation shows that augmenting the LLM with real-time tool access consistently improves prediction accuracy over the LLM alone across both ontology-constrained and non-ontology-constrained fields, demonstrating a practical approach to automated standardization of biomedical metadata.

08.
arXiv (quant-ph) 2026-06-17

Quantum mechanics in configuration space in context

arXiv:2606.17622v1 Announce Type: new Abstract: To enhance the way in which wave-particle duality is implemented in the modelling of quantum mechanical systems, Bukhari et al. [New J. Phys. 27, 084501 (2025)] recently introduced an alternative approach to quantum mechanics, namely quantum mechanics in configuration space. This formalism is based on a physically motivated quantisation of Newtonian mechanics and promotes the classical position-velocity states (x,v) to pairwise distinguishable quantum states. The resulting |x,v> states form the basis of the Hilbert space of individual quantum mechanical particles and evolve along classical trajectories. In this paper, we consider the modelling of a mechanical particle in free space and put quantum mechanics in configuration space into context. It is shown that this formalism increases the continuity between quantum and classical mechanics by avoiding a conceptual inconsistency associated with the definition of momentum in canonical quantisation. In addition, we emphasise that standard quantum mechanics and quantum mechanics in configuration space are based on two distinct formulations of classical mechanics.

09.
medRxiv (Medicine) 2026-06-23

Linking mpox wastewater surveillance with reported clinical cases in three countries in Sub-Saharan Africa

The emergence of the novel monkeypox virus (MPXV) clade Ib in the Democratic Republic of the Congo (DRC) and neighboring countries in late 2023 highlighted the need for rapid, scalable surveillance approaches to support outbreak detection and response. As part of the ODIN-Mpox project, wastewater surveillance (WWS) systems were established as an emergency public health measure in three Sub-Saharan African countries (DRC, Tanzania, and Burkina Faso) to evaluate the feasibility of wastewater-based monitoring for mpox and strengthen local surveillance capacity. Between January 2025 and April 2026, 117 wastewater samples were collected from selected sites and analyzed for MPXV DNA using targeted qPCR assays. Clinical mpox data were obtained from national surveillance systems and WHO reports to assess epidemiological linkages between wastewater detections and reported infections. Six wastewater samples tested positive for MPXV DNA. During the study period, DRC experienced the highest disease burden, with weekly reported cases peaking at about 3,000 in January 2025, while Tanzania reported a peak of 20 weekly cases in March 2025. No confirmed clinical cases were reported in Burkina Faso. No clear relationship was observed between reported case numbers and qPCR Ct values in positive wastewater samples. Despite the low detection frequency, the project demonstrated the operational feasibility of implementing MPXV wastewater surveillance in resource-limited settings and established laboratory capacity for environmental monitoring of emerging infectious diseases. Given the early stage of WWS implementation in the region, the study identified opportunities for further system strengthening, including optimization of sample processing and reporting workflows, improved access to laboratory supplies, and enhanced integration of environmental and clinical surveillance data streams. These findings highlight the value of WWS as a complementary component of integrated public health surveillance systems and emphasize the need for continued investment in laboratory capacity, harmonized methodologies, governance frameworks, and knowledge exchange to enhance outbreak preparedness and response in low-resource settings.

10.
arXiv (CS.LG) 2026-06-16

Branching Flows: Discrete, Continuous, and Manifold Flow Matching with Splits and Deletions

arXiv:2511.09465v4 Announce Type: replace-cross Abstract: Diffusion and flow matching approaches to generative modeling have shown promise in domains where the state space is continuous, such as image generation or protein folding & design, and discrete, exemplified by diffusion large language models. They offer a natural fit when the number of elements in a state is fixed in advance (e.g. images), but require ad hoc solutions when, for example, the length of a response from a large language model, or the number of amino acids in a protein chain is not known a priori. Here we propose Branching Flows, a generative modeling framework that, like diffusion and flow matching approaches, transports a simple distribution to the data distribution. But in Branching Flows, the elements in the state evolve over a forest of binary trees, branching and dying stochastically with rates that are learned by the model. This allows the model to control, during generation, the number of elements in the sequence. We also show that Branching Flows can compose with any flow matching base process on discrete sets, continuous Euclidean spaces, smooth manifolds, and `multimodal' product spaces that mix these components. We demonstrate this in three domains: small molecule generation (multimodal), antibody sequence generation (discrete), and protein backbone generation (multimodal), and show that Branching Flows is a capable distribution learner with a stable learning objective, and that it enables new capabilities.

11.
arXiv (CS.CV) 2026-06-24

Training-Time Optical Priors for Wireless Capsule Endoscopy Classification: Hemoglobin-Aware Input Fusion with Cross-Vendor Evaluation

Background. RGB-trained classifiers for wireless capsule endoscopy (WCE) conflate hemoglobin contrast with bile staining and illumination falloff, limiting sensitivity to small-vessel vascular findings such as Lymphangiectasia. We introduce a physics-informed framework that injects an analytic, Monte-Carlo-inspired hemoglobin prior into a standard classifier purely at training time – to our knowledge the first use of an explicit optical light-transport prior in WCE classification. Methods. On Kvasir-Capsule (47,238 frames, 43 patients, 11 evaluable classes; patient-disjoint split) we test, across 6 seeds against an RGB-only EfficientNet-B0 baseline: (i) a 5-channel input-fusion variant feeding the prior P_blood alongside RGB; (ii) a distillation variant that runs on plain 3-channel RGB at inference; and (iii) a three-stream extension adding a temporal Transformer and an autoencoder-residual stream. We replicate across ResNet-18 and ConvNeXt-Tiny and report cross-vendor zero-shot transfer on the public Galar cohort. Results. Input fusion lifts cross-seed macro-AUC 0.760 -> 0.783 (5/6 seeds positive); distillation reaches 0.773; the three-stream model reaches 0.804 (+0.044 over baseline, paired DeLong p < 1e-4). Lymphangiectasia AUC rises 0.238 -> 0.337, sign-consistent across all 6 seeds. A four-variant ablation reveals a parameterization-mechanism boundary: only the spatial-channel form lifts. Cross-vendor zero-shot on Galar retains ~60% of the ConvNeXt-Tiny lift.

12.
medRxiv (Medicine) 2026-06-22

Assessment of adaptive functioning in Angelman syndrome using the Vineland Adaptive Behavior Scales, Third Edition

Purpose: This study examined longitudinal trajectories of adaptive functioning in 331 individuals with Angelman syndrome (AS) using the Vineland Adaptive Behavior Scales, Third Edition (Vineland-3) and examined differences by molecular subtype. Methods: A total of 331 individuals (156 females, 47%) with genetically confirmed AS (ages 6 months to 52 years) were assessed between 2018 and 2025, including 207 with a deletion subtype, 63 with uniparental disomy or imprinting defect, and 61 with a UBE3A point mutation. Growth scale values were analyzed using linear mixed-effects models with log2-transformed age. Results: Individuals with deletion subtypes demonstrated significantly lower adaptive functioning across domains compared to those with non-deletion subtypes. Adaptive skills across all Vineland-3 subdomains increased nonlinearly with age, showing faster growth early in life that slowed over time, with largely parallel trajectories across subtypes. Conclusion: Individuals with AS demonstrate slow but steady growth in adaptive functioning that continues into adulthood, with progress varying by molecular subtype. These findings provide updated natural history benchmarks and demonstrate the utility of the Vineland-3 for clinical trials.

13.
arXiv (CS.CV) 2026-06-18

SPARX: Secure and Privacy-Aware Approximate CNN Acceleration with Edge RISC-V SoC

Edge-AI systems increasingly require real-time CNN inference under strict energy, performance, security, and privacy constraints. Approximate computing improves hardware efficiency by exploiting the error resilience of neural network workloads; however, most approximate CNN accelerators do not jointly consider secure, privacy-aware edge deployment. This paper presents SPARX, a Secure and Privacy-Aware Approximate CNN Acceleration framework integrated within a heterogeneous RV32IMC RISC-V System-on-Chip (SoC). SPARX combines a custom RISC-V instruction extension, an approximate logarithmic CNN acceleration unit, a lightweight differential-noise-based privacy engine, and a challenge-response authentication mechanism. To guide arithmetic selection, an approximation-aware decision framework is introduced that uses the Approximation Severity Index (ASI), Approximation Efficiency (AE), Quality of Approximation (QoA), Approximation Figure-of-Merit (AFOM), and Hardware Acceleration Efficiency (HAE). Evaluation across 11 state-of-the-art approximate MAC architectures identifies the Iterative Logarithmic Multiplier (ILM) as the most suitable design, achieving 51.7% area reduction, 81.5% power reduction, and 2.13x throughput improvement compared with an accurate radix-4 Booth MAC, while only reducing ResNet-20/CIFAR-10 accuracy by 2.82 percentage points. FPGA implementation on a Xilinx VC707 platform achieves 58.4 GOPS/W energy efficiency at 250 MHz, while 28-nm CMOS physical implementation validates ASIC feasibility

14.
medRxiv (Medicine) 2026-06-15

International Consensus Guideline on Management of Genitourinary Adverse Events Associated with Prostate Cancer Radiotherapy

Purpose/Objective: Genitourinary (GU) adverse events (AEs) are common during and after pelvic radiation therapy (RT) for prostate cancer and can substantially impact quality of life. We convened an international committee to establish consensus in the prevention, mitigation, and management of radiation-related acute and late GU AEs, as there are no relevant evidence-based consensus guidelines to inform treating providers. Materials/Methods: A systematic evidence review focused on mitigation and management of radiation-related acute and late GU AEs was performed in PubMed, Embase and Cochrane. The following topics were addressed: management of acute GU AEs in the intact and post-operative settings; RT techniques; bladder outlet obstruction procedures; and indications for urology referral or hyperbaric oxygen therapy (HBO). Evidence-based consensus recommendations were developed using a Delphi process. We highlight the current state of evidence and evidence gaps worthy of future study. Results: Consensus was reached for 31 key questions. For management of lower urinary tract symptoms (LUTS), most evidence comes from trials in patients without cancer and not undergoing RT. A consensus algorithm for medical management of acute GU AEs was developed with the following highlights: (a) alpha blockers as 1st-line for obstructive symptoms in the intact setting, (b) anti-spasmodics as 1st -line for irritative symptoms in the intact setting, and (c) anti-spasmodics as 1st -line in the post-operative setting. The consensus algorithm provides an ordered list of medications to offer if 1st -line options afford inadequate relief. For RT fractionation, randomized clinical trial (RCT) data are available. 40% of panelists rarely or never use standard fractionation over moderate hypofractionation for patients with baseline LUTS, but most consider moderate hypofractionation over SBRT for AUA IPSS > 15. For patients with severe obstructive LUTS (most commonly AUA IPSS >20), the panel recommends a prophylactic bladder outlet obstruction procedure and, if obstructive symptoms improve, consideration of moderate hypofractionation or SBRT, based on retrospective data. There is one RCT supporting use of HBO for late radiation cystitis. Conclusions: The consensus guideline synthesizes available evidence and expert opinion across key clinical decision points to provide practical guidance in the prevention, mitigation, and management of radiation-related acute and late GU AEs in prostate cancer RT. Envisioned as a living document with periodic updates, this guideline serves as a resource for practicing radiation oncologists by outlining expert-derived consensus recommendations of evidence-based care in areas where high-quality data is limited.

15.
arXiv (CS.CV) 2026-06-19

EventVLA: Event-Driven Visual Evidence Memory for Long-Horizon Vision-Language-Action Policies

Memory remains a critical bottleneck for long-horizon robotic manipulation, as standard Vision-Language-Action (VLA) policies often fail when task-relevant cues become occluded or unobservable over time. While existing memory-augmented methods utilize historical context, they either suffer from severe information bottlenecks, incur high latency via decoupled dual systems, or rely on unselective buffers that accumulate massive visual redundancies. To address these limitations, we introduce EventVLA, an end-to-end framework founded on the concept of sparse visual evidence memory that comprises two core components: foundational visual anchors to retain initial and short-term contexts, and a dynamic Keyframe Evidence Memory (KEM) module. Specifically, KEM directly predicts future keyframe probabilities from the VLA's latent embeddings to autonomously capture and store sparse, task-critical visual events. This foresight-driven mechanism empowers the policy to dynamically evaluate the future causal utility of current observations, preserving transient visual evidence before it becomes unobservable. Furthermore, we propose RoboTwin-MeM, a diagnostic benchmark specifically designed to evaluate non-Markovian manipulation tasks with interactive visual evidence. Extensive evaluations show that across 17 memory-requiring simulation tasks and 4 real-world bimanual tasks, EventVLA achieves an average success rate improvement of +40% over state-of-the-art memory-augmented VLAs.

16.
arXiv (quant-ph) 2026-06-12

Trading symmetry for Hilbert-space dimension in Bell-inequality violation

arXiv:2601.02893v3 Announce Type: replace Abstract: In quantum information, asymmetry, i.e., the lack of symmetry, is a resource allowing one to accomplish certain tasks that are otherwise impossible. Similarly, in a Bell test using any given Bell inequality, the maximum violation achievable using quantum strategies respecting or disregarding a certain symmetry can be different. In this work, we focus on the symmetry involved in the exchange of parties and explore when we have to trade this symmetry for a lower-dimensional quantum strategy in achieving the maximal violation of given Bell inequalities. For the family of symmetric Collins-Gisin-Linden-Massar-Popescu inequalities, we provide evidence showing that there is no such trade-off. However, for several other Bell inequalities with a small number of dichotomic measurement settings, we show that symmetric quantum strategies in the minimal Hilbert space dimension can only lead to a suboptimal Bell violation. In other words, there exist symmetric Bell inequalities that can only be maximally violated by asymmetric quantum strategies of minimal dimension. In contrast, one can also find examples of asymmetric Bell inequalities that are maximally violated by symmetric correlations. The implications of these findings on the geometry of the set of quantum correlations and the possibility of performing self-testing therefrom are briefly discussed.

17.
medRxiv (Medicine) 2026-06-22

Reliable quantification of renal function from frozen blood samples

BACKGROUND: Differences in renal function may affect Alzheimer disease (AD) blood biomarker levels independent of AD pathology. Although renal function was unaccounted for in foundational AD blood biomarker studies, there is potential to address this through quantification of estimated glomerular filtration rate (eGFR) from frozen serum and plasma samples. However, the validity of eGFR evaluation from long-term frozen blood samples is unknown. METHODS: Adults aged 50-85 with at least 2 vascular risk factors were recruited from vascular surgery or cardiology clinics in Tucson, Arizona from 2022-2025. Individuals with creatinine assessments in point-of-care whole blood (POC-WB) and frozen serum and plasma samples using the iSTAT (Abbott) were included. eGFR was calculated using the 2021 CKD-EPI creatinine equation without race. Agreement between POC-WB and frozen blood samples was assessed using Cohen's kappa with linear weights. RESULTS: 134 participants (mean [SD] age: 72.6 [7.5] years, 39.6% female, 23.1% chronic kidney disease) had POC-WB eGFR available. Frozen serum and plasma samples had strong agreement with POC-WB for eGFR (Kw= 0.90-0.95, P

18.
arXiv (CS.CL) 2026-06-18

Dango: A Strictly L1-Only Large Language Model for Studying Second Language Acquisition

We introduce Dango, a 1.8B-parameter large language model designed for controlled studies of L1-to-L2 (Japanese-to-English) transfer in second language acquisition (SLA). While previous studies have explored SLA in language models, they have predominantly relied on smaller or non-decoder models, limiting their ability to generate open-ended text and reducing their suitability as practical L2 simulators. We identify a key challenge when scaling models to this size: L2 contamination within the "monolingual" pretraining corpus used for L1 acquisition. To address this, we propose a filtering method to reduce premature exposure to English while preserving realistic, minimal exposure. We then fine-tune the model on LLM-generated L2-learning lessons to simulate the L2 acquisition process. Our evaluations confirm that Dango develops human-like L2 production patterns, outperforming both unfiltered and standard multilingual baselines. We release the model, data, and code to facilitate reproducible computational SLA research and learner-facing applications.

19.
arXiv (CS.CV) 2026-06-17

SPATIA: Multimodal Generation and Prediction of Spatial Cell Phenotypes

Understanding how cellular morphology, gene expression, and spatial context jointly shape tissue function is a central challenge in biology. Image-based spatial transcriptomics technologies now provide high-resolution measurements of cell images and gene expression profiles, but existing methods typically analyze these modalities in isolation or at limited resolution. We address the problem by introducing SPATIA, a multi-level generative and predictive model that learns unified, spatially aware representations by fusing morphology, gene expression, and spatial context from the cell to the tissue level. SPATIA also incorporates a spatially conditioned generative framework with confidence-aware OT reweighting and morphology-profile alignment for modeling target-state morphology distributions. Specifically, we propose a confidence-aware flow matching objective that reweights weak optimal-transport pairs based on uncertainty. We further apply morphology-profile alignment to encourage biologically meaningful image generation, enabling the modeling of microenvironment-dependent phenotypic transitions. We assembled a multi-scale dataset consisting of 25.9 million cell-gene pairs across 17 tissues. We benchmark SPATIA against 18 models across 12 tasks, spanning categories such as phenotype generation, annotation, clustering, gene imputation, and cross-modal prediction. SPATIA achieves improved performance over state-of-the-art models, improving generative fidelity by 8% and predictive accuracy by up to 3%.

20.
arXiv (CS.CV) 2026-06-11

CountZES: Counting via Zero-Shot Exemplar Selection

Object counting in complex scenes is particularly challenging in the zero-shot (ZS) setting, where instances of unseen categories are counted using only a class name. Existing ZS counting methods that infer exemplars from text often rely on off-the-shelf open-vocabulary detectors (OVDs), which in dense scenes suffer from semantic noise, appearance variability, and multi-instance proposals. Alternatively, random image-patch sampling is employed, which fails to accurately delineate object instances. Since counting is sensitive to exemplar quality, such selection strategies often yield poorly representative exemplars, leading to inaccurate count estimation. To address these issues, we propose CountZES, an inference-only approach for object counting via ZS exemplar selection. CountZES discovers diverse exemplars through three synergistic stages: Detection-Anchored Exemplar (DAE), Density-Guided Exemplar (DGE), and Feature-Consensus Exemplar (FCE). DAE refines OVD detections to isolate precise single-instance exemplars. DGE introduces a density-driven, self-supervised paradigm to identify statistically consistent and semantically compact exemplars, while FCE reinforces visual coherence through feature-space clustering. Together, these stages yield a complementary exemplar set that balances textual grounding, count consistency, and feature representativeness. Experiments on diverse datasets demonstrate CountZES superior performance among ZOC methods while generalizing effectively across domains.

21.
medRxiv (Medicine) 2026-06-15

Validating Field-Feasible Measures of Recent Khat Use: A Diagnostic Accuracy Study Comparing Amphetamine Immunoassay and Assisted Self-Report Against HPLC in an Ethiopian Male Cohort

Background: Khat (Catha edulis) is a widely consumed natural amphetamine-analog used across East Africa and the Arabian Peninsula. Accurate field-feasible measurement of recent khat use is a prerequisite for large-scale epidemiological research; yet no validated alternatives to laboratory reference methods have been identified in the scientific literature. This nested validation study evaluated the diagnostic accuracy of two point-of-care measures, a commercial amphetamine immunoassay and a Timeline Followback (TLFB) Assisted Self-Report (ASR), against high-performance liquid chromatography (HPLC) quantification of urinary norephedrine (NE), while additionally assessing agreement between the two field measures. Methods: A prospective, random sub-sample of 119 male participants aged 18-40 years from the Gilgel Gibe Field Research Center (GGFRC) longitudinal cohort, Ethiopia (validation timepoint T2, 2015), was used. Three index-reference comparisons were conducted: (1) amphetamine immunoassay (nal von minden, Drug-Screen AMP test, 300 ng/mL cutoff) vs. HPLC; (2) binary ASR (past-week use) vs. HPLC; and (3) binary ASR vs. immunoassay. Sensitivity (positive percent agreement, PPA), specificity (negative percent agreement, NPA), positive predictive value (PPV), negative predictive value (NPV), overall accuracy (overall percent agreement, OPA), and Cohen's kappa were calculated with 95% confidence intervals. Pre-specified secondary analyses applied three pharmacokinetically-informed recall windows (0-2, 3-5, and 6-7 days prior to interview) to ASR. Results: Against HPLC (77 positive, 42 negative), the immunoassay showed perfect specificity (1.0 [0.916-1.0]) and PPV (1.0 [0.91-1.0]) but low sensitivity (0.52 [0.40-0.64]), NPV (0.53 [0.42-0.65]), overall accuracy (0.69 [0.60-0.77]), and weak kappa (0.43 [0.34-0.52]). Binary ASR showed high sensitivity (0.96 [0.89-0.99]), specificity of 0.60 [0.433-0.74], PPV (0.81 [0.72-0.89]), NPV (0.89 [0.72-0.98]), with overall accuracy 0.83 [0.75-0.89] and moderate kappa (0.60 [0.51,0.69]). Restricting ASR to use within 0-2 days improved specificity to 0.69 [0.52-0.84], PPV to 0.86 [0.77-0.93], overall accuracy to 0.87 [0.79-0.93], and kappa to 0.69 [0.61-0.78] (moderate), while sensitivity (0.96 [0.89-0.99]) and NPV (0.89 [0.72-0.98]) remained stable. Against the immunoassay, ASR achieved high PPA of (1.0 [0.91-1.0]), NPA of 0.35 [0.25-0.47], OPA of 0.57 [0.48-0.66], and minimal kappa (0.27 [0.19-0.35]). Conclusions: Time-stratified ASR (0-2 days) is a valid, scalable alternative to biological testing for recent khat use in resource-limited settings. The immunoassay's 300 ng/mL cutoff functions as a marker of heavy or recent high-dose khat use rather than any-use detection. Its perfect specificity and PPV make it valuable as a confirmatory test for substantial exposure, while its lower sensitivity reflects calibration to amphetamine rather than to khat-derived cathinone metabolite. Keywords: khat; Catha edulis; diagnostic accuracy; STARD; self-report; immunoassay; HPLC; Ethiopia; substance use measurement

22.
medRxiv (Medicine) 2026-06-15

The clinical utility of functional testing in fibroblasts to diagnose primary mitochondrial disease

Genome sequencing of the heterogeneous primary mitochondrial disorders (PMD) frequently reveals variants of uncertain significance that require functional tests for diagnosis, and does not identify variants in all patients. We analyzed mitochondrial enzyme assays, blue native polyacrylamide gel electrophoresis (BN-PAGE) with in-gel activity staining, complex I assembly blot, and select protein abundances in fibroblasts of a case series of 204 PMD patients divided into functional classes, in comparison to 51 controls and 53 differential diagnostic conditions. Overall, sensitivity and specificity for respiratory chain enzyme assays were 46% and 93% respectively, for BN-PAGE 40% and 98%, for complex I assembly assay 49% and 99%. The overall sensitivity of all tests was 76%, specificity 93%, with positive predictive value 96% and negative predictive value 67%. Categories with high sensitivity were isolated complex deficiencies, nuclear DNA-encoded mitochondrial protein synthesis defects, co-factor defects, and mitochondrial amino-acyl-tRNA synthetase conditions when aided by protein abundance. Mitochondrial DNA mutations and maintenance disorders showed poor sensitivities. Secondary dysfunctions were rare. A complete battery of functional tests showed strong diagnostic clinical utility in fibroblasts.

23.
arXiv (CS.CV) 2026-06-15

CineOrchestra: Unified Entity-Centric Conditioning for Cinematic Video Generation

Cinematic video depicts multiple subjects acting or interacting at specific moments, captured with deliberate camera movement, and stitched together by shot transitions. Together, these elements demand a level of fine-grained control beyond current text-to-video models. Existing work addresses each axis in isolation: multi-subject personalization, temporal control, multi-shot synthesis, or camera control; no prior framework jointly integrates all four. We present CineOrchestra, a unified video diffusion model that controls subjects, events, cameras, and shot transitions simultaneously. Our key insight is that these heterogeneous cinematic elements share a fundamental structure: each is an entity acting over a specific temporal interval, which can therefore all be expressed through one shared structure of entity-centric conditioning primitives, augmented with reference images for visual entities. This formulation reduces the architectural challenge to a single positional encoding problem, which we solve with two parameter-free coordinated rotary embeddings: (a) an interval-sampled temporal RoPE that yields consistent attention behavior across events of dramatically varying duration, and (b) a 2D entity-temporal cross-attention RoPE that disambiguates per-entity conditions and routes each to its corresponding spatiotemporal region. On two new benchmarks, CineOrchestra outperforms six per-axis specialists on dense caption following and shot-transition timing, with consistent gains in a pairwise user study and component ablations.

24.
arXiv (CS.CL) 2026-06-15

Every Eval Ever: A Unifying Schema and Community Repository for AI Evaluation Results

AI evaluations are widely used for testing and understanding progress. However, the diverse evaluators bring with them inconsistencies that challenge analysis and comparison. First, results are saved in incompatible formats, scattered across leaderboards, papers, blog posts, evaluation harness logs, and custom repositories. Second, results are created by different evaluation frameworks, which produce divergent scores for nominally identical evaluations and record metadata inconsistently, hindering comparison, cross-community evaluation science, cost reduction, and reuse. We introduce Every Eval Ever, the first shared schema and community-crowdsourced repository for AI evaluation results. The schema standardizes how evaluations are represented in a unified, single JSON document. It is source-agnostic by design, ingesting results from evaluation harnesses and papers alike, and optionally stores per-instance outputs for fine-grained analysis. We contribute: (i) a community-governed metadata schema with a companion instance-level schema, the first standardization effort of its kind; (ii) automatic converters from popular formats, evaluation harnesses, and leaderboards to the unified schema; and (iii) a crowdsourced community database hosted on Hugging Face, currently spanning to date 22,235 models, 2,273 unique benchmarks, and 31 evaluation formats.

25.
arXiv (CS.AI) 2026-06-15

VHDLSuite: Unified Pipeline for LLM VHDL Generation with Data Synthesis and Evaluation

arXiv:2606.13735v1 Announce Type: cross Abstract: Large Language Models (LLM) have shown impressive capabilities in Register Transfer Level (RTL) code generation, particularly for Verilog. However, evaluating their performance with other Hardware Description Languages (HDL), especially VHDL, remains limited although its distinct language characteristics, such as stricter semantic rules, introduce evaluation considerations that differ from Verilog. This lack of coverage restricts fully understanding of how well current models generalize across hardware design languages with differing structures and semantics. To address this gap, we introduce VHDLSuite, a benchmark-centered infrastructure for scalable VHDL generation evaluation, integrating automated benchmark synthesis, executable validation, and multi-model diagnostic analysis. First, we propose a data pipeline that automatically converts Verilog designs and their accompanying testbenches into executable VHDL benchmark instances, followed by VUnit/GHDL-based validation to ensure each released task is compilable, runnable, and consistently checkable in the VHDL environment. Second, we introduce VHDLBench, a benchmark with over 200 VHDL problems with complete and validated testbenches across a wide range of complexity levels. Third, we extensively evaluate cutting-edge LLMs and uncover key challenges specific on LLM-aided VHDL generation. Our findings provide important insights and support future work in multi-language hardware design automation.Our data pipeline, benchmark, and evaluation framework will be open-sourced.