×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Jonghyun Chung ×
换一批
01.
arXiv (CS.CL) 2026-06-24

ParaPairAudioBench: Paralinguistic Pairwise Audio Benchmark for LALM-as-a-Judge

Large Audio-Language Models (LALMs) have been widely used as judge models for the automatic evaluation of generated speech. However, prior approaches predominantly focus on holistic naturalness, leaving fine-grained paralinguistic distinctions underexplored. We introduce ParaPairAudioBench, a pairwise benchmark of 5,175 audio pairs across five paralinguistic dimensions: Style, Rate, Emphasis, Age, and Gender. Our experiments show that current LALM judges still lag behind human judgments by 32%p on average and exhibit severe calibration failures, particularly in Tie cases where the correct decision is to abstain. To further analyze lexical versus acoustic reliance, the benchmark includes both same-transcript and cross-transcript conditions. ParaPairAudioBench enables multi-dimensional, calibration-aware assessment of the reliability of LALM-as-a-Judge for paralinguistic speech evaluation.

02.
arXiv (CS.CV) 2026-06-18

Pre-Deployment Robustness Stress Testing for CT Segmentation Systems Using Clinically Motivated Multi-Corruption Augmentation

Deep learning-based CT segmentation systems often achieve high accuracy on clean benchmark images, but their performance may degrade under heterogeneous clinical imaging conditions such as noise, resolution loss, contrast variation, intensity shift, and artifacts. This instability can limit reliable deployment in real-world medical imaging workflows. We propose Robustness via Augmented Multi-corruption Pipeline (RAMP), a robustness-oriented augmentation framework for CT segmentation. RAMP combines anatomically constrained spatial perturbations, CT intensity transformations, and stochastic multi-corruption composition to expose models to clinically plausible image degradation during training. Across two CT segmentation evaluation settings, RAMP achieved the strongest corrupted-image performance and the smallest clean-to-corrupted robustness gap. In the five-organ noisy evaluation benchmark, RAMP improved mean corrupted Dice from 0.610 to 0.753 and reduced the robustness gap from 0.264 to 0.064 compared with the nnU-Net baseline. In Abdomen1K, RAMP improved mean corrupted Dice from 0.633 to 0.789 and reduced the robustness gap from 0.290 to 0.070. Although RAMP did not achieve the highest clean-image Dice, it substantially mitigated worst-case segmentation collapse under severe image degradation. These results suggest that multi-corruption augmentation can serve as a practical pre-deployment strategy for improving the reliability of CT segmentation systems in heterogeneous clinical environments.