×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Ferencik ×
换一批
01.
medRxiv (Medicine) 2026-06-17

Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxydiphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy

Background Bone-avid tracer myocardial scintigraphy for the diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM) has traditionally employed imaging at one or 3-hour intervals. Technetium-99m hydroxydiphosphonate (99mTc-HDP) has unique characteristics that may enable earlier imaging. We investigated the diagnostic concordance of immediate versus 1-hour acquisitions. Methods Consecutive patients with suspected ATTR-CM underwent planar imaging and SPECT/CT immediately and at 1-hour following the administration of 99mTc-HDP. Perugini grades and heart to contralateral lung (H/CL) ratios were assessed. Target-to-background ratios (TBRs) were calculated on the SPECT/CT acquisitions using the left ventricular (LV) septum and three background regions: aorta, LV blood-pool, and vertebrae. We assessed diagnostic concordance using Cohen's Kappa ({kappa}), temporal stability using paired t-tests, and correlation between timepoints using Pearson's coefficient (r). The 1-hour SPECT/CT interpretation served as the protocol reference standard. Results Forty-eight patients (83% male; median age, 80 [73-85] years) were evaluated. One-hour SPECT/CT identified 19 positive and 29 negative cases. Immediate SPECT/CT demonstrated 100% diagnostic concordance with the 1-hour reference standard ({kappa} = 1.000; 95% CI: 1.00 to 1.00; p < 0.001). The LV septum/LV Blood-Pool TBR showed the highest correlation (r = 0.956; 95% CI: 0.922 to 0.975; p < 0.001). The LV Septum/Aorta TBR demonstrated high correlation (r = 0.918; 95% CI: 0.857 to 0.953; p < 0.001) and remained stable in the ATTR-negative cohort (-0.02; 95% CI: -0.08 to 0.04; p = 0.54). Significant decrease in the LV Septum/Vertebrae TBR in the ATTR-negative (-0.55; 95% CI: -0.64 to -0.47; p < 0.001) and ATTR-positive cohorts (-1.14; 95% CI: -1.39 to -0.89; p < 0.001) was observed. Conclusions Immediate 99mTc-HDP SPECT/CT is diagnostically concordant with standard 1-hour protocols. By leveraging SPECT/CT and the favorable kinetics of 99mTc-HDP, immediate-phase imaging can accurately reproduce 1-hour acquisitions in cases of suspected ATTR-CM. This expedited approach may improve nuclear laboratory throughput and patient satisfaction.