×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Choudhary ×
换一批
01.
arXiv (CS.CL) 2026-06-19

NRITYAM: Language Models Meet Art and Heritage of Dance

Language models have become essential tools in shaping modern workflows. However, their global effectiveness hinges on a nuanced understanding of local socio-cultural contexts. To address this gap, we present NRITYAM, a comprehensive benchmark for evaluating the cultural comprehension capabilities of language models in the context of global dance traditions. NRITYAM comprises 9,260 carefully curated question-answer pairs spanning 12 languages, making it the largest dataset dedicated to evaluating cultural knowledge in dance. The dataset has been developed from the ground up through close collaboration with native dance artists and native speakers of the languages, who authored and validated culturally relevant questions specific to their regions. We evaluate a broad set of models, including large language models, small language models, multimodal large language models, and small multimodal language models. As a multilingual and multicultural benchmark, NRITYAM sets a new standard for evaluating the ability of AI systems to understand and reason about traditional performing arts. Detailed dataset samples are available at~\url{https://github.com/niladrighosh03/NRITYAM}.

02.
arXiv (CS.AI) 2026-06-18

Clin-JEPA: A Multi-Phase Co-Training Framework for Joint-Embedding Predictive Pretraining on EHR Patient Trajectories

arXiv:2605.10840v3 Announce Type: replace-cross Abstract: We present Clin-JEPA, a multi-phase co-training framework for joint-embedding predictive (JEPA) pretraining on EHR patient trajectories. JEPA architectures have enabled latent-space planning in robotics and high-quality representation learning in vision, but extending the paradigm to EHR data – to obtain a single backbone that simultaneously forecasts patient trajectories and serves diverse downstream risk-prediction tasks without per-task fine-tuning – remains an open challenge. Existing JEPA frameworks either discard the predictor after pretraining (I-JEPA, V-JEPA) or train it on a frozen pretrained encoder (V-JEPA 2-AC), leaving the encoder unaware of the rollout signal that the retained predictor must use at inference; co-training the encoder and predictor under a shared JEPA prediction objective would supply this grounding, but naïve co-training is unstable, with representation collapse and online/target drift causing autoregressive rollout to diverge. Clin-JEPA's five-phase pretraining curriculum – predictor warmup, joint refinement, EMA target alignment, hard sync, and predictor finalization – addresses each failure mode by phase, stably co-training a Qwen3-8B-based encoder and a 92M-parameter latent trajectory predictor. On MIMIC-IV ICU data, three independent evaluations support the framework: (1) latent $\ell_1$ rollout drift uniquely converges ($-$15.7%) over 48-hour horizons while baselines and ablations diverge (+3% to +4951%); (2) the encoder learns a clinically discriminative latent geometry (deteriorating-patient cohorts displace 4.83$\times$ further than stable patients in latent space, vs $\leq$2.62$\times$ for baseline encoders); (3) a single backbone outperforms strong tabular and sequence baselines on multi-task downstream evaluation. Clin-JEPA achieves mean AUROC 0.851 on ICareFM EEP and 0.883 on 8 binary risk tasks (+0.038 and +0.041 vs baseline average).

03.
arXiv (CS.LG) 2026-06-16

Unlocking Latent Dimensions: Exploring Representations of Large-Scale X-ray Scattering Data using Variational Autoencoders

arXiv:2606.14999v1 Announce Type: new Abstract: Scientific user facilities generate X-ray scattering data faster than traditional workflows can process them. We address this challenge across two settings, offline dataset exploration and live on-the-fly analysis. We train a domain-specific attention-based Convolutional Variational Autoencoder (C-VAE) on 1.5 million X-ray scattering images to learn low-dimensional representations capturing structural variation across diverse experimental conditions. The learned latent space reveals well-organized clusters and smooth trajectories reflecting experimental progression. It further supports controlled synthetic scattering image generation across diverse structural states. When deployed without retraining, the model organizes time-resolved film formation experiments at two synchrotron facilities into interpretable latent structures. Benchmarking against DINOv3 (ViT-7B), a general-purpose vision foundation model, demonstrates that domain-specific training yields more interpretable latent organization for scattering data. Both workflows are integrated within Latent Space Explorer, a component of the MLExchange platform, supporting interactive structural exploration across archived datasets and live experiments.

04.
medRxiv (Medicine) 2026-06-17

Diagnostic Concordance of Immediate Versus 1-Hour Technetium-99m Hydroxydiphosphonate Scintigraphy in Suspected Transthyretin Amyloid Cardiomyopathy

Background Bone-avid tracer myocardial scintigraphy for the diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM) has traditionally employed imaging at one or 3-hour intervals. Technetium-99m hydroxydiphosphonate (99mTc-HDP) has unique characteristics that may enable earlier imaging. We investigated the diagnostic concordance of immediate versus 1-hour acquisitions. Methods Consecutive patients with suspected ATTR-CM underwent planar imaging and SPECT/CT immediately and at 1-hour following the administration of 99mTc-HDP. Perugini grades and heart to contralateral lung (H/CL) ratios were assessed. Target-to-background ratios (TBRs) were calculated on the SPECT/CT acquisitions using the left ventricular (LV) septum and three background regions: aorta, LV blood-pool, and vertebrae. We assessed diagnostic concordance using Cohen's Kappa ({kappa}), temporal stability using paired t-tests, and correlation between timepoints using Pearson's coefficient (r). The 1-hour SPECT/CT interpretation served as the protocol reference standard. Results Forty-eight patients (83% male; median age, 80 [73-85] years) were evaluated. One-hour SPECT/CT identified 19 positive and 29 negative cases. Immediate SPECT/CT demonstrated 100% diagnostic concordance with the 1-hour reference standard ({kappa} = 1.000; 95% CI: 1.00 to 1.00; p < 0.001). The LV septum/LV Blood-Pool TBR showed the highest correlation (r = 0.956; 95% CI: 0.922 to 0.975; p < 0.001). The LV Septum/Aorta TBR demonstrated high correlation (r = 0.918; 95% CI: 0.857 to 0.953; p < 0.001) and remained stable in the ATTR-negative cohort (-0.02; 95% CI: -0.08 to 0.04; p = 0.54). Significant decrease in the LV Septum/Vertebrae TBR in the ATTR-negative (-0.55; 95% CI: -0.64 to -0.47; p < 0.001) and ATTR-positive cohorts (-1.14; 95% CI: -1.39 to -0.89; p < 0.001) was observed. Conclusions Immediate 99mTc-HDP SPECT/CT is diagnostically concordant with standard 1-hour protocols. By leveraging SPECT/CT and the favorable kinetics of 99mTc-HDP, immediate-phase imaging can accurately reproduce 1-hour acquisitions in cases of suspected ATTR-CM. This expedited approach may improve nuclear laboratory throughput and patient satisfaction.