×

Academic Intelligence · Curated Daily

Explore the Frontier of Global Academia

AcademicHub aggregates real-time literature from top journals and preprint platforms. Build your personal research radar and let large language models compile cross-disciplinary analysis briefings automatically.

Authors: Butters ×
Shuffle
01.
medRxiv (Medicine) 2026-06-17

Proteomics Uncovers Cryptic JPH2 Loss in Paediatric Dilated Cardiomyopathy

Despite recent advances in next-generation sequencing, genetic diagnostic rates for dilated cardiomyopathy (DCM) remain low. Among paediatric DCM, causes are often heritable, with a greater frequency of de novo, recessive and syndromic causes of disease. Novel diagnostic methods are therefore required to solve monogenic cases. To assess the value of proteomics as a diagnostic tool for paediatric DCM, we obtained left ventricle myocardial samples from paediatric patients undergoing heart transplantation at the Royal Children's Hospital, Melbourne. We performed genome sequencing and proteomics and leveraged this multi-omics dataset to uncover the molecular cause of disease in a gene elusive proband. The proband carried a heterozygous JPH2 frameshift variant identified on clinical exome sequencing. However, proteomic analysis showed a pronounced downregulation of JPH2, suggestive of biallelic loss-of-function. Closer inspection of the genomic data revealed a large inversion (~8.34 Mb) with a breakpoint falling within intron 5 of JPH2 that displaces the 3'UTR from the coding transcript. The two variants were confirmed to be in trans using long read DNA sequencing, consistent with a diagnosis of JPH2 autosomal recessive DCM. Finally, we applied RNA sequencing with total RNA library preparation to show that transcripts containing a 3'UTR were reduced to ~10% relative to controls. As a proof-of-principle, we present the first reported use of proteomics from explanted cardiac tissue to provide a genetic diagnosis. Our methodology has broad relevance to patients with genetically unsolved Mendelian diseases, who might undergo organ transplantation as part of clinical management.

02.
arXiv (CS.CV) 2026-06-18

Clinically Aligned Geometry Constraints for Robust IVUS Vessel Boundary Segmentation

Intravascular ultrasound (IVUS) lumen and external elastic membrane (EEM) segmentation is important for quantitative coronary plaque burden assessment. Errors in lumen or EEM delineation directly propagate to plaque area, plaque burden and geometric measurements. However, standard methods prioritising overlap scores often suffer from boundary drift and topology errors, leading to inaccurate clinical measurements. We present GeoCat, a geometry-consistent network that processes 5-frame IVUS clips using dual Cartesian-polar encoders with cross-domain attention and temporal fusion. A differentiable geometry consistency loss directly supervises clinically relevant descriptors including diameters, orientations, and cross-sectional areas. The model is trained on 12,242 annotated frames from 146 patients acquired with two commercial IVUS systems. We evaluate performance using both segmentation accuracy and plaque-relevant clinical metrics, including Dice/IoU, boundary measures(95HD (mm), ASSD), topology violation rate, and clinical geometry errors (dmax/dmin, angles, and areas). On our dataset, GeoCat achieves a Dice of 0.93, reduces 95HD to 0.14 mm, and lowers topology violations to 1.0%. Importantly, it significantly improves geometric fidelity, yielding diameter errors of 0.13-0.16 mm and angular errors of ~8 degrees, supporting reliable plaque burden quantification.