×

Academic Intelligence · Curated Daily

Explore the Frontier of Global Academia

AcademicHub aggregates real-time literature from top journals and preprint platforms. Build your personal research radar and let large language models compile cross-disciplinary analysis briefings automatically.

Authors: BA ×
Shuffle
01.
arXiv (CS.CV) 2026-06-15

Stream3D: Sequential Multi-View 3D Generation via Evidential Memory

View-conditioned 3D generators such as SAM 3D, TRELLIS, and Hunyuan3D produce high-quality object reconstructions from a single view, but real-world visual observation often arrives as long monocular streams. Naively applying these generators to each streaming frame independently leads to severe temporal inconsistency in the generated results. To address this problem, we propose Stream3D, the first training-free streaming mechanism that turns a frozen view-conditioned 3D generator into a streaming generator with constant cross-chunk memory. Stream3D achieves this by maintaining a compact evidential memory, which selectively caches the most informative historical frames based on a proposed evidence score mechanism. As the stream progresses, the memory dynamically updates to retain a fixed number of informative frames, preventing the memory footprint from growing linearly with sequence length. This also prevents degradation over long sequences and keeps the underlying generator completely unchanged without retraining, architectural modifications, or auxiliary losses. Evaluated on both realistic and synthetic streaming benchmarks, Stream3D outperforms latent-transport baselines, including KV-cache reuse and flow-based feature editing, across both photometric and geometric metrics. More details can be found at: https://stream-3d.github.io/stream3d.github.io/.

02.
arXiv (CS.AI) 2026-06-19

CADBench: A Multimodal Benchmark for AI-Assisted CAD Program Generation

arXiv:2605.10873v2 Announce Type: replace-cross Abstract: Recovering editable CAD programs from images or 3D observations is central to AI-assisted design, but progress is difficult to measure because existing evaluations are fragmented across datasets, modalities, and metrics. We introduce CADBench, a unified benchmark for multimodal CAD program generation. CADBench contains 18,000 evaluation samples spanning six benchmark families derived from DeepCAD, Fusion 360, ABC, MCB, and Objaverse; five input modalities including clean meshes, noisy meshes, single-view renders, photorealistic renders, and multi-view renders; and six metrics covering geometric fidelity, executability, and program compactness. STEP-based families are stratified by B-rep face count and all families are diversity-sampled to support controlled analysis across complexity and object variation. We benchmark eleven CAD-specialized and general-purpose vision-language systems, generating more than 1.4 million CAD programs. Under idealized inputs, specialized mesh-to-CAD models substantially outperform code-generating VLMs, which remain far from reliable CAD program reconstruction. CADBench further reveals three recurring failure modes: reconstruction quality degrades with geometric complexity, CAD-specialized models can be brittle under modality shift, and model rankings change across metrics. Together, these results position CADBench as a diagnostic testbed for measuring progress in editable 3D reconstruction and multimodal CAD understanding. The benchmark is publicly available at https://github.com/anniedoris/CADBench.

03.
arXiv (CS.CV) 2026-06-16

Object Tokens as a Bridge Between Segmentation and Visual Question Answering in Robotic Surgery

Visual Question Answering (VQA) in robotic surgery, referred to as surgical VQA, requires high-level understanding of complex surgical scenes and the integration of visual perception with language reasoning, with the potential to support surgical training and intraoperative decision-making. Recent Vision-Language Models (VLMs) have shown promising performance through parameter-efficient fine-tuning; however, most existing approaches rely on coarse visual grounding, typically limited to bounding boxes, which fails to capture the fine-grained spatial structure of surgical objects. In this work, we propose a unified framework that jointly performs pixel-level segmentation and visual question answering within a single framework. Our approach integrates a VLM with a Segment Anything Model (SAM)-based decoder and represents scene elements as object tokens generated by the VLM. These object tokens guide answer prediction and are further projected to the SAM-based decoder to produce segmentation masks. By optimizing the object token embeddings through both segmentation and question answering objectives, the model learns spatially grounded representations that enhance visual reasoning while providing explicit pixel-level grounding. We evaluate the proposed method on the private RAMIE (Robot-Assisted Minimally Invasive Esophagectomy) dataset and the public EndoVis18 dataset, where it consistently outperforms baseline methods for surgical VQA. These results demonstrate that incorporating context-aware object tokens into vision-language models improves fine-grained surgical scene understanding.

04.
arXiv (CS.CL) 2026-06-15

Beyond Perplexity: UTF-8 Validity in Byte-aware Language Models

Byte-level tokenization enables language models to handle any Unicode input, but models can generate invalid UTF-8 sequences when encountering rare or unseen characters. We investigate the relationship between training scale and UTF-8 generation reliability with a 355M parameter model trained on 80B tokens from a balanced multilingual corpus of English, Japanese, Korean, and Chinese. We introduce multiple evaluation protocols that isolate UTF-8 structural validity from language modeling. UTF-8 validity convergence lags perplexity by a roughly a factor of two: perplexity stabilizes after 2.1B tokens, but UTF-8 validity requires 4.2B tokens. In context-free generation, rare characters achieve higher structural validity than common characters, suggesting over-specialization of frequent character representations. Through experiments, we observed that reliable UTF-8 generation is a distinct capability requiring evaluation beyond perplexity.

05.
arXiv (CS.LG) 2026-06-15

Running the Gauntlet: Re-evaluating the Capabilities of Agents Beyond Familiar Environments

arXiv:2606.14397v1 Announce Type: new Abstract: As agentic systems continue to evolve and are widely deployed in real-world scenarios, there is a growing demand to faithfully evaluate their capabilities. However, current benchmarks are typically built on popular applications with relatively simple tasks and focus on a narrow set of capabilities while overlooking broader dimensions, resulting in saturated performance on modern agents and failing to probe their limitations. To this end, we introduce GauntletBench, a web-based benchmark for evaluating agent generalisation in challenging scenarios, focusing on three underexplored capabilities (temporal perception, graphical understanding, and 3D reasoning), across five less-covered professional applications (Video Editor, Workflow Builder, 3D Modeller, Flight Analyser, and Circuit Designer), each with 20 vision-intensive tasks (100 in total). Our benchmark provides a modular pipeline that comprises an environment compatible with both open- and closed-source agent frameworks, a controlled web-based application, a well-structured task suite, and an automated evaluation engine with diverse metrics. Contrary to widespread expectations, our empirical results reveal that frontier agentic systems remain far from achieving human-level performance. Even the state-of-the-art agent achieves only a 19.1% success rate on our GauntletBench, highlighting the limitations in these overlooked capabilities and generalisation. By comparison, non-expert human annotators achieve over 80% success on our challenging yet feasible tasks, revealing the substantial gap between current agent capabilities and those required for complex real-world scenarios.

06.
arXiv (quant-ph) 2026-06-19

A Finite-Volume Scheme for the Continuum Extrapolation of Lattice Step-Scaling in (2+1)D Hamiltonian U(1) Gauge Theory

arXiv:2606.20029v1 Announce Type: cross Abstract: We propose a finite-volume scheme to perform controlled continuum extrapolations of the lattice step-scaling function, a key ingredient for determining the running coupling in a Hamiltonian lattice gauge theory in small volumes. As a testbed, we employ a dual Hamiltonian formulation of pure U(1) gauge theory in (2+1) dimensions and an operator basis that remains efficient toward weak coupling. We describe the implementation of static external charges on the spatial lattice and study, using matrix product states, the resulting confining string, from which we extract the static potential and a force-based renormalized coupling. Using the proposed finite-volume scheme, we demonstrate a stable continuum limit of the step-scaling function on the lattice sizes accessible to present Hamiltonian simulations. The method is readily extendable to other gauge groups and dimensions, providing a pathway toward Hamiltonian step-scaling studies in other theories.

07.
medRxiv (Medicine) 2026-06-15

Investigation of Intra-Fraction Stability and Inter-Fraction Reproducibility of Deep Inspiration Breath-Hold Across Two Hypofractionated Radiotherapy Regimens in the HYPORT Adjuvant Study.

Background: Deep Inspiration Breath Hold (DIBH) is a widely used respiratory motion management technique for minimizing cardiac dose in left-sided breast radiotherapy. In the Breast HYPORT Adjuvant study, DIBH was employed for cardiac sparing in patients without nodal irradiation using a standardized institutional protocol with the Varian Real-time Position Management (RPM) system. Both moderate-hypofractionation (control arm - 40Gy in 15 fractions) and one-week hypofractionation (experimental arm - 26 Gy in 5 fractions) regimens were delivered using this protocol. This study aimed to evaluate the robustness of DIBH by analyzing intra-fraction stability and inter-fraction reproducibility of breath-hold amplitude across the two treatment regimens. Methods: Respiratory waveforms acquired during each treatment session were analyzed to determine the median breath-hold amplitude and its standard deviation during beam delivery. Intra-fraction stability was assessed from vari- ations within individual treatment sessions, while inter-fraction reproducibility was evaluated relative to the simula- tion waveform amplitude across all treatment sessions. These parameters were compared between the two HYPORT regimens to examine breath-hold consistency during treatment delivery. Moreover, an additional comparison was made between the one-week hypofractionation regimen and the first five fractions of the moderate-hypofractionation regimen to evaluate the effect of treatment duration . Lung volumes from free-breathing and DIBH CT scans were analyzed to assess the effectiveness of patient breath-hold training. Results: Both arms demonstrated an average 1.7-fold increase of air volume in lung during the breath-hold position, confirming the effective implementation of DIBH during treatment planning and delivery. Structured training resulted in increased breath-hold amplitudes, with gains of 22.87% and 24.16% with respect to the first trial session in the experimental and control arms, respectively. Both regimens receive equivalent doses for approximately the same air volume in lung . Despite the different prescription doses in the two arms (26 Gy vs. 40 Gy), the experimental arm achieved an equivalent mean heart dose of 2.91% (75.6 cGy) compared with 2.95% (118.51 cGy) in the control arm, suggesting a similar cardiac preservation protocol adopted during treatment planning. Intra-fraction stability was similar between the control arm and the experimental arm, with median amplitude variations of 1.006 mm (95% CI: [0.998-1.015]) and 1.079 mm (95% CI: [1.067-1.097]), respectively. In contrast, inter-fraction reproducibility improved in the experimental arm, with lower deviation from simulation amplitude (0.44 {+/-} 0.24 mm vs. 0.66 {+/-} 0.25 mm) for the entire treatment schedule. The stability and reproducibility of experimental arm were further compared with the first five fractions of the control arm. The results were similar to those of the experimental arm. Conclusion: In this study, we compared two treatment regimens in terms of intra-fraction stability and inter-fraction reproducibility during DIBH radiotherapy. Both regimens demonstrated comparable intra-fraction stability, indicating effective motion management irrespective of treatment duration. However, the experimental arm showed better inter- fraction reproducibility, suggesting more consistent breath-hold performance throughout the treatment course. Based on stability and reproducibility, a reasonable narrowing of the DIBH gating window may be implemented with minor changes to the institutional protocol. The observed trend highlights the potential for improved consistency with the experimental approach and supports further investigation to better understand the underlying factors and strengthen these findings in future studies.

08.
arXiv (CS.AI) 2026-06-11

Physics-informed generative AI for semiconductor manufacturing: Enforcing hard physical constraints in generative models by construction

arXiv:2606.11247v1 Announce Type: cross Abstract: Generative models are increasingly used to propose designs, data, and control actions for physical systems, yet many such systems are governed by hard physical constraints rather than by perceptual plausibility. Semiconductor manufacturing provides a demanding test case: generated masks, layouts, synthetic defect data, and process recipes must obey lithography, transport, reaction, and device-physics constraints, because physically invalid samples are not merely low quality but unusable. This Perspective argues that semiconductor manufacturing exposes a broader computational-science challenge, namely that generative AI for constrained physical domains must be physics-informed by construction, not corrected only through post-hoc filtering. We survey the emerging architectural toolkit, including physics-informed diffusion, PDE-constrained variational models, neural-operator priors, and conservation-law-respecting generative networks, and show how it connects to differentiable lithography, TCAD, process simulation, and autonomous experimentation. We identify four integration patterns between generative models and physics-based simulators, and we propose a research agenda centered on physics-fidelity benchmarks, differentiable simulator infrastructure, and multimodal foundation models for physical design and manufacturing. The central claim is analytical rather than rhetorical: where physical validity is the binding criterion of success, architectures that enforce it by construction should be expected to outperform those that filter for it after the fact, and the fab is the setting where this distinction is sharpest.

09.
arXiv (quant-ph) 2026-06-17

Hybrid Ferromagnet-SNSPDs: Single photon induced order-to-disorder transition in ferromagnets coupled to thin film superconductors

arXiv:2606.17177v1 Announce Type: cross Abstract: The development of midwave and longwave infrared single photon detectors is crucial for their emerging applications in spectroscopy, remote sensing, exoplanet detection, and free space quantum communications. However, existing sensors need to be operated at extremely low temperatures (0.08-0.9K) to reduce dark noise and hence require the use of advanced cryogenics such as dilution refrigerators or $^3$He cryogens, significantly limiting applications. Here we propose a vortex-engineering approach based on a hybrid phase transition in a ferromagnet/superconductor bilayer to increase the operating temperature of infrared single photon detectors up to 3.75K. We show that the introduction of a ferromagnetic layer produces a local magnetic field which impedes vortex crossing in the superconductor, reducing dark noise. When a single photon is incident, the photon-induced hotspot causes an order-to-disorder transition in the ferromagnet, leading to a vortex-induced phase transition in the superconducting layer. By engineering the ferromagnet's Curie temperature to be close to the device's operating temperature, single photon sensitivity can be achieved at increased operating temperatures. We predict at midwave/longwave infrared wavelengths (3-14$\mu$m) the operating temperature can be raised to 3.25-3.75K, enabling significantly simpler cooling systems.

10.
arXiv (CS.CV) 2026-06-18

CAOA – Completion-Assisted Object-CAD Alignment

Accurately aligning CAD models to their corresponding objects in indoor RGB-D scans is a central challenge in 3D semantic reconstruction. The task requires estimating a 9-Degree-of-Freedom (DoF) pose-position, rotation, and scale along three axes-but is hindered by noisy and incomplete scans, as well as segmentation errors that cause geometric distortions. We present Completion-Assisted Object-CAD Alignment (CAOA), a method that integrates a semantically and contextually aware point cloud completion module with a symmetry-aware relative pose estimation algorithm, enabling precise alignment of CAD models to scanned objects. Existing completion methods are typically trained and evaluated on synthetic datasets, which often fail to generalize to real-world scans. To bridge this gap, we introduce a synthetic data generation strategy tailored to indoor scenes, significantly reducing the synthetic-to-real domain gap-validated through quantitative comparisons with widely used completion datasets. In addition, we release S2C-Completion, an expert-annotated dataset of over 8,500 object-CAD pairs from Scan2CAD, created for real-world indoor single-object completion and intended as a new benchmark for this task. For object-CAD alignment, we incorporate symmetry information via a symmetry-aware loss, improving robustness to symmetric ambiguities. On the Scan2CAD benchmark, CAOA achieves a 17% accuracy improvement over state-of-the-art methods.

11.
Nature Medicine 2026-06-08

Post-adjuvant chemotherapy in ctDNA-positive patients with resected colorectal cancer: a randomized phase 3 trial

Authors:

Tumor-informed circulating tumor DNA (ctDNA) enables detection of molecular residual disease (MRD) after curative resection of colorectal cancer (CRC), but whether early intervention improves outcomes remains uncertain. ALTAIR was a randomized, double-blind, phase 3 trial embedded in the CIRCULATE-Japan platform evaluating a post-adjuvant ctDNA surveillance strategy with treatment initiation upon molecular recurrence. Patients with resected stage 0–IV CRC who became ctDNA positive after completion of standard-of-care therapy and had no radiological evidence of disease were randomly assigned (1:1) to receive trifluridine/tipiracil (FTD/TPI) or placebo for 6 months. The primary endpoint was investigator-assessed disease-free survival (DFS). Between July 2020 and June 2023, 243 patients were randomized to FTD/TPI (n = 122) or placebo (n = 121). Median DFS was 9.30 months with FTD/TPI and 5.55 months with placebo (hazard ratio = 0.79, 95% confidence interval: 0.60–1.05, P = 0.107), and the primary endpoint was not met. FTD/TPI increased grade 3 or higher hematologic adverse events (73.0% versus 3.3%) without new safety signals. These findings indicate that post-adjuvant intervention with FTD/TPI did not significantly improve DFS in ctDNA-positive patients without radiological disease. ClinicalTrials.gov identifier: NCT04457297 . In the randomized, double-blind phase 3 ALTAIR trial, patients with resected colorectal cancer who became positive for circulating tumor DNA during post-adjuvant surveillance received trifluridine/tipiracil hydrochloride therapy, which did not significantly prolong disease-free survival compared with placebo.

12.
arXiv (CS.CV) 2026-06-24

GeoIMO: Geometry-Driven Independent Motion Classification for Event Cameras

Existing automotive event datasets rely on appearance-based annotations from frame pipelines, making them poorly suited for motion-aware event perception. We present a geometry-driven, annotation-free framework that classifies detected objects as static or independently moving by exploiting ego-motion structure directly from the event stream. A Focus of Expansion model with yaw compensation estimates global background motion, while objects are labeled as moving when local motion deviates from this prediction, as quantified by a scale-invariant residual. Temporal stabilization improves robustness across consecutive event windows. The method requires no learning, no manual motion labels, and works with any input bounding boxes. Experiments on MVSEC and the Prophesee 1 Megapixel Automotive Detection dataset demonstrate consistent performance across diverse driving scenarios, with yaw compensation improving results during turns and a simple translational local model offering a favorable accuracy-efficiency trade-off.

13.
arXiv (CS.AI) 2026-06-17

Talking to Your Data: Exploring Embodied Conversation as an Interface for Personal Health Reflection

arXiv:2606.17767v1 Announce Type: cross Abstract: Personal health data from wearables are typically presented through dashboards of charts and summary statistics, requiring users to actively interpret patterns and implications. We explore an alternative interaction paradigm: engaging with personal health data through an embodied conversational agent that facilitates objective data reflection in dialogue with the user. We present a system that combines lightweight preprocessing of wearable data with a Unity-based embodied character. Internally, the system follows a dual-agent design in which an Observer agent extracts descriptive statistics and temporal trends, and a Presenter agent communicates these findings through "spoken statistics," intentionally refraining from clinical advice to isolate the impact of the interaction modality. We evaluate this approach through a simulated-self user study (N=5) using a within-subject design. Participants adopted health personas and goals derived from the LifeSnaps dataset to compare traditional dashboard exploration with embodied conversational reflection. Our evaluation focuses on perceived understanding, the specificity of generated actions, and the cognitive shift from passive viewing to active sensemaking. The paper contributes a functional prototype, a design pattern for objective health data narrative generation, and early empirical insights into how embodiment affects the interpretation of personal health metrics.

14.
arXiv (quant-ph) 2026-06-17

Many-body spectral transitions through the lens of the variable-range SYK2 model

arXiv:2412.14280v2 Announce Type: replace-cross Abstract: The Sachdev-Ye-Kitaev (SYK) model is a cornerstone in the study of quantum chaos and holographic quantum matter. Real-world implementations, however, deviate from the idealized all-to-all connectivity, raising questions about the robustness of its chaotic properties. In this work, we investigate a quadratic SYK model with distance-dependent interactions governed by a power-law decay. By analytically and numerically studying the spectral form factor (SFF), we uncover how transitions present in the single-particle limit carry over to the many-body system. Non-trivial cancellations in the one-loop contributions lead to a robustness of the SFF under a considerable reduction of the interaction range. Further suppression leads to a breakdown of perturbation theory around the infinite-range path-integral saddle and the appearance of new spectral regimes, marked by a higher dip and the emergence of a secondary plateau. Our results highlight the interplay between single-particle criticality and many-body dynamics, offering new insights into the quantum chaos-to-localization transition and its reflection in spectral statistics.

15.
medRxiv (Medicine) 2026-06-16

Validation of a Smartphone-Image-Based Computer-Vision Model for Lean Mass and Body Fat Estimation Against Dual-Energy X-ray Absorptiometry

Introduction Body composition, rather than body weight alone, is an increasingly important health metric, and preservation of lean mass has become a central concern in obesity treatment, aging, and chronic disease management. Dual-energy X-ray absorptiometry (DXA) provides accurate assessment of fat and lean tissue, but its cost and logistical requirements limit repeated measurement. Computer-vision approaches show promise for estimating adiposity from smartphone images, but lean-mass estimation remains less established. Methods We evaluated a computer-vision body composition model, applied to consumer-grade smartphone photographs, against DXA in a held-out validation sample of 195 adults from an ongoing cross-sectional study. Body fat percentage and total lean mass percentage were co-primary outcomes; for total lean mass percentage, an image-only configuration (no added covariates) was pre-specified as primary. Agreement was quantified using Lin's concordance correlation coefficient (CCC) as the lead statistic, with Pearson correlation, mean absolute error, root mean square error, mean bias, and Bland-Altman limits of agreement. In secondary analyses, appendicular lean mass and total lean mass percentage were each estimated with and without routine anthropometric and demographic inputs (body weight, height, age, and sex). Results Total lean mass percentage agreed with DXA from image features alone (CCC 0.916). Body fat percentage, estimated with routine inputs added, agreed at least as closely (CCC 0.930). Adding routine inputs barely changed agreement for total lean mass percentage but markedly improved it for appendicular lean mass, an absolute quantity that scales with body size. Conclusions A smartphone-image-based model estimated both body fat and lean mass with strong agreement to DXA, with lean mass percentage from image features alone. The approach needs no fixed equipment or ionizing radiation. Whether it can track change over time, including in incretin-based weight loss where lean mass preservation is a concern, was not assessed in this cross-sectional study.

16.
arXiv (CS.LG) 2026-06-11

Anatomy of Post-Training: Using Interpretability to Characterize Data and Shape the Learning Signal

arXiv:2606.12360v1 Announce Type: new Abstract: Language-model post-training is the main stage at which model behavior is shaped, yet it still largely involves optimization of scalar rewards that summarize diverse desiderata. This abstraction gives practitioners little visibility into what their data actually teaches models, allowing spurious correlations to be learned by a model and inducing undesirable behaviors such as over-stylization and sycophancy. To address this problem, we ask: can we inspect a preference dataset before optimization and decide, at the level of concepts, which behaviors a model should be allowed to learn? Motivated by this, we introduce a data-centric post-training pipeline that uses interpretability protocols to develop statistical hypotheses for the latent concepts separating preferred from dispreferred generations, making them explicit for fine-grained user feedback. Building on this view, we unify several interpretability-based training protocols as ways of shaping rewards via feature or data interventions. Empirically, we show that our pipeline diagnoses undesirable signals in existing preference data, mitigates off-target learning, and can also help amplify or shape desired properties such as safeguards and model personality. More broadly, our results suggest that interpretability can turn post-training from optimizing opaque proxy rewards into a process of auditing and sculpting the learning signal itself.

17.
arXiv (CS.LG) 2026-06-16

Characterizing Admissible Objective Functions for Hierarchical Clustering

arXiv:2604.23628v2 Announce Type: replace-cross Abstract: Hierarchical clustering is a fundamental task in data analysis, but classical methods have long lacked a principled objective function. Dasgupta [STOC~2016] took an important step toward addressing this gap by proposing a well-motivated objective function for cluster trees. Cohen-Addad et al. [J. ACM 2019] subsequently introduced the notion of admissibility: an objective function is admissible if, whenever the input similarity matrix admits generating trees, its minimizers are precisely those generating trees.They also gave a necessary and sufficient condition for admissibility within a family of objective functions based on aggregate intercluster similarity. We refer to this family as sum-type objective functions. However, apart from Dasgupta's original objective function, no explicit admissible objective functions in this family were provided. In this paper, we study admissible objective functions for hierarchical clustering in two directions. For sum-type objective functions, we give a complete characterization when the scaling function is a symmetric polynomial of degree at most two, and we derive sufficient conditions for degree-three polynomials. We also show that the recursive sparsest cut algorithm achieves an O$(\phi)$-approximation ratio for the admissible objective functions covered by our characterization, where $\phi$ is the approximation factor of the sparsest cut subroutine. We then introduce max-type objective functions, where cluster interaction is measured by maximum, rather than aggregate, intercluster similarity. For this class, we characterize which objective functions are admissible for arbitrary symmetric scaling functions and give a complete characterization when the scaling function is a symmetric polynomial of degree at most two.

18.
arXiv (CS.AI) 2026-06-15

Think Fast: Estimating No-CoT Task-Completion Time Horizons of Frontier AI Models

arXiv:2606.07157v2 Announce Type: replace Abstract: Many efforts to ensure frontier AI models are safe rely on monitoring their chain-of-thought (CoT) reasoning. If models become able to perform sufficiently complex reasoning internally, without explicit thinking tokens, this would undermine such oversight. We measure how well frontier models reason without CoT across a suite of over 30,000 questions spanning 43 benchmarks in domains including math, coding, puzzles, causality, theory-of-mind, and strategic reasoning. To compare models against humans, we estimate the $50\%$-task-completion time horizon (TH): the human time required for tasks a model completes with $50\%$ success rate. We complement this with a $50\%$ reasoning token horizon: the minimum number of o3-mini reasoning tokens needed for tasks a model solves with $50\%$ success rate. We find that the no-CoT $50\%$ TH of frontier models has been doubling roughly every year over the past six years, with GPT-5.5's TH reaching over 3 minutes and reasoning token horizon exceeding 1,500 tokens. Our median estimates predict that frontier no-CoT THs could exceed 7 minutes by 2028, and 25 minutes by 2030, though these projections carry substantial uncertainty. We recommend frontier developers track this explicitly.

19.
medRxiv (Medicine) 2026-06-15

International Consensus Guideline on Management of Genitourinary Adverse Events Associated with Prostate Cancer Radiotherapy

Purpose/Objective: Genitourinary (GU) adverse events (AEs) are common during and after pelvic radiation therapy (RT) for prostate cancer and can substantially impact quality of life. We convened an international committee to establish consensus in the prevention, mitigation, and management of radiation-related acute and late GU AEs, as there are no relevant evidence-based consensus guidelines to inform treating providers. Materials/Methods: A systematic evidence review focused on mitigation and management of radiation-related acute and late GU AEs was performed in PubMed, Embase and Cochrane. The following topics were addressed: management of acute GU AEs in the intact and post-operative settings; RT techniques; bladder outlet obstruction procedures; and indications for urology referral or hyperbaric oxygen therapy (HBO). Evidence-based consensus recommendations were developed using a Delphi process. We highlight the current state of evidence and evidence gaps worthy of future study. Results: Consensus was reached for 31 key questions. For management of lower urinary tract symptoms (LUTS), most evidence comes from trials in patients without cancer and not undergoing RT. A consensus algorithm for medical management of acute GU AEs was developed with the following highlights: (a) alpha blockers as 1st-line for obstructive symptoms in the intact setting, (b) anti-spasmodics as 1st -line for irritative symptoms in the intact setting, and (c) anti-spasmodics as 1st -line in the post-operative setting. The consensus algorithm provides an ordered list of medications to offer if 1st -line options afford inadequate relief. For RT fractionation, randomized clinical trial (RCT) data are available. 40% of panelists rarely or never use standard fractionation over moderate hypofractionation for patients with baseline LUTS, but most consider moderate hypofractionation over SBRT for AUA IPSS > 15. For patients with severe obstructive LUTS (most commonly AUA IPSS >20), the panel recommends a prophylactic bladder outlet obstruction procedure and, if obstructive symptoms improve, consideration of moderate hypofractionation or SBRT, based on retrospective data. There is one RCT supporting use of HBO for late radiation cystitis. Conclusions: The consensus guideline synthesizes available evidence and expert opinion across key clinical decision points to provide practical guidance in the prevention, mitigation, and management of radiation-related acute and late GU AEs in prostate cancer RT. Envisioned as a living document with periodic updates, this guideline serves as a resource for practicing radiation oncologists by outlining expert-derived consensus recommendations of evidence-based care in areas where high-quality data is limited.

20.
arXiv (CS.AI) 2026-06-18

Deep-Learning-Based Pixelated Microwave Filter Design and Characterization using Electro-Optical Electric-Field Measurements

arXiv:2606.18402v1 Announce Type: cross Abstract: Traditional microwave filter design typically relies on iterative parameter tuning and predefined topologies, which limits design space and increases development time. This study uses a deep learning approach combining convolutional neural networks with genetic algorithms to automate pixelated microwave filter synthesis. To validate the approach experimentally, both S-parameter and spatial electric-field measurements were analyzed. The synthesized low-pass filter demonstrated excellent agreement between simulated and measured performance, achieving a 7 GHz passband with over 20 dB suppression beyond 9.5 GHz. Electro-optical measurements, for the first time, revealed electric field patterns that resemble coupled transmission-lines or stub structures, providing insight into the emergent characteristics of AI-generated designs.

21.
medRxiv (Medicine) 2026-06-10

Human-centred design approaches to health facility design: Evidence from perinatal care settings in Ethiopia and Bangladesh

While significant progress has been made in perinatal outcomes over recent decades in low- and middle-income countries (LMICs), maternal and newborn quality improvement initiatives often fail to account for the spatial conditions in which they are implemented. Health systems are increasingly deploying evidence-based care models into built environments that are not optimally structured to meet the needs of its patient population. As the principal users, patients and health care workers can offer pragmatic insights about improving these structural designs. Our objective was to gather insights from patients, providers, and companions about how the physical design of their health facilities influenced their experience receiving or delivering perinatal care. We conducted a prospective observational study using a human-centred design (HCD) approach to analyse perceptions of the quality of perinatal care across two low resource settings: Ethiopia and Bangladesh. Using engagement and assessment tools, we conducted interviews, focus groups, facility walk-throughs, co-design workshops, and infrastructural assessments with patients, companions, providers, and Ministry of Health representatives. Descriptive statistics and thematic analysis were used to identify key learnings and develop recommendations. Across both countries, participants identified the need for facility layouts that better support privacy, mobility during labour, alternative birth positions, companion involvement, cultural and religious practices, sanitation, and provider visibility. Based on these insights, we developed six recommendations to better align health facility infrastructure with maternal and newborn care delivery needs. Our findings suggest that investments in health facility infrastructure may improve care experiences and help enable respectful, safe, and evidence-based maternal and newborn care. Alongside targeted spatial improvements, government authorities responsible for health facility planning should incorporate participatory design processes to ensure infrastructure reflects the needs of patients, companions, and providers and supports high-quality care delivery.

22.
arXiv (quant-ph) 2026-06-19

Computing noise-canceling observables via Pauli propagation

arXiv:2606.20441v1 Announce Type: new Abstract: The pursuit of quantum advantage is driving the co-evolution of quantum processors and classical simulation methods. Despite advances in scale and quality, the accuracy of quantum simulation is ultimately limited by error rates and sampling overheads. Similarly, while classical simulation methods such as Pauli propagation have made remarkable progress, their accuracy is ultimately limited by the exponential growth of operator paths and the truncations needed to control memory and runtime. Here we show that these complementary limitations can be mitigated by embedding Pauli propagation within a hybrid error-mitigation framework that reduces quantum sampling overhead while achieving lower truncation errors with fewer classical resources than traditional Pauli propagation alone. In this framework, a target observable is classically propagated through noise-canceling inverse channels, producing a modified observable that is measured directly on a quantum processor. We prototype two implementations and benchmark their performance numerically on canonical models that challenge traditional Pauli propagation. We also perform experiments on a quantum processor using 56 superconducting qubits, revealing the tradeoffs of their respective truncation strategies. These results illustrate how classical and quantum resources can be orchestrated to extend observable estimation beyond the limits of either approach alone, providing a foundation for quantum-centric supercomputing and future demonstrations of quantum advantage.

23.
arXiv (CS.CV) 2026-06-18

Hand-4DGS: Feed-Forward 3D Gaussian Splatting for 4D Hand Reconstruction from Egocentric Videos

Dynamic 3D hand reconstruction from egocentric videos is essential for next-generation computing platforms such as AR/VR and AI glasses. Despite its importance, most prior works focus either on multi-view 3D hand reconstruction or on 4D human body reconstruction. Egocentric 4D hand reconstruction remains challenging due to fast head motion, rapid hand dynamics, severe occlusions, and inherent ambiguity from single-view observations. To address these challenges, we introduce Hand-4DGS, the first feed-forward framework for reconstructing dynamic 4D hands directly from egocentric videos, enabling both fast (~60 FPS) inference and strong generalization. Our approach incorporates a mesh-guided representation for structural priors and temporal convolutions to model dynamic motion. We evaluate our framework on two challenging egocentric datasets, H2O and ARCTIC, and demonstrate significant improvements over baselines. Our method benefits from the generalization capability of feed-forward networks and effective 2D image supervision through Gaussian splatting, without requiring expensive 3D hand pose ground-truth annotations.

24.
arXiv (CS.CV) 2026-06-19

HEad and neCK TumOR (HECKTOR) 2025: Benchmark of Segmentation, Diagnosis, and Prognosis in Multimodal PET/CT

Head and neck cancers (HNC) represent a significant global health burden, with accurate tumor delineation being essential for effective radiotherapy planning. The complexity of the oropharyngeal anatomy, combined with the heterogeneous appearance of tumors on imaging, makes manual segmentation time-intensive and subject to inter-observer variability. Beyond segmentation, predicting long-term clinical outcomes, such as recurrence-free survival (RFS), and determining human papillomavirus (HPV) status from noninvasive imaging, remain challenging yet clinically valuable goals. The HECKTOR 2025 challenge addresses these needs by establishing a comprehensive benchmark for automated HNC analysis using multimodal PET/CT imaging and electronic health records. Building on previous editions (2020-2022), this challenge features an expanded multi-institutional dataset comprising over 1,100 patients from 10 centers worldwide. Participants were tasked with three complementary objectives: (1) segmenting primary gross tumor volumes (GTVp) and metastatic lymph nodes (GTVn), (2) predicting recurrence-free survival, and (3) classifying HPV status. The challenge attracted 35 registered teams, with 15 final submissions evaluated on a held-out test set. Top-performing algorithms achieved a mean Dice similarity coefficient of 0.75 for segmentation, a concordance index of 0.66 for survival prediction, and a balanced accuracy of 0.56 for HPV classification. This paper presents a comprehensive analysis of the submitted methodologies, evaluates their performance across different lesion characteristics, and discusses their implications for clinical translation in automated oncology workflows and decision support systems.

25.
arXiv (CS.CV) 2026-06-16

DenseControl: Instance-Level Controllable Synthesis of Dense Crowd Image

In this paper, we introduce DenseControl, a novel pipeline for generating dense crowd images. Specifically, DenseControl meticulously positions and sizes each generated instance to align precisely with the predefined coordinates and scales. Based on this, we further allow for control over the background, style, and attributes of instances. The motivation behind DenseControl stems from the observation of two main challenges in synthesizing crowd images: controlling signal embedding and maintaining topological integrity when imparting instance scale guidance. To address these, we first introduce the Isolated Object Embedding (IOE) map, a novel representation that facilitates spatial location control while mitigating the difficulties associated with learning projections for model. Secondly, we propose an Implicit Scale Embedding (ISE) strategy that seamlessly integrates with the IOE map to encode precise scale information. To further enhance the efficacy of combining ISE with the IOE map, we incorporate a Position Shortcut mechanism that enhances cross-attention to alleviate projection challenges. We evaluate DenseControl through two lenses: synthesis quality and applicability in latent applications. Experiments across different control conditions demonstrate DenseControl achieves state-of-the-art results in dense crowd image synthesis. Furthermore, we showcase applications in augmenting crowd analysis under data scarcity, transfer learning, and weather generalization scenes, to highlight the practical utility of DenseControl. The codebase will be released.