×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: B. -X. Qi ×
换一批
01.
arXiv (quant-ph) 2026-06-12

Observation of Non-Gaussian Magnon Dynamics in a Two-Dimensional Long-Range XY Model

arXiv:2606.13499v1 Announce Type: new Abstract: Non-Gaussian evolution of high-order spin correlations characterizes important properties of quantum many-body systems. In practice, decoherence, statistical fluctuation and miscalibration of experimental parameters all hinder the witness of non-Gaussian dynamics. Here we demonstrate the crossover between Gaussian and non-Gaussian dynamics on a two-dimensional XY model with long-range and spatially structured interaction using a trapped ion quantum simulator. We prepare different initial densities of magnon excitations and verify the dynamics of single-spin observables for the engineered Hamiltonian. Then we compare the high-order spin correlations with the mean-field solution and the Holstein-Primakoff approximation, and demonstrate the non-Gaussian behavior in a way independent of the calibration errors. Our work provides a verifiable path from classically simulatable dynamics to regimes where quantum advantage may emerge.

02.
arXiv (CS.CV) 2026-06-16

UniT: Unified Multimodal Chain-of-Thought Test-time Scaling

Unified models can handle both multimodal understanding and generation within a single architecture, yet they typically operate in a single pass without iteratively refining their outputs. Many multimodal tasks, especially those involving complex spatial compositions, multiple interacting objects, or evolving instructions, require decomposing instructions, verifying intermediate results, and making iterative corrections. While test-time scaling (TTS) has demonstrated that allocating additional inference compute for iterative reasoning substantially improves language model performance, extending this paradigm to unified multimodal models remains an open challenge. We introduce UniT, a framework for multimodal chain-of-thought test-time scaling that enables a single unified model to reason, verify, and refine across multiple rounds. UniT combines agentic data synthesis, unified model training, and flexible test-time inference to elicit cognitive behaviors including verification, subgoal decomposition, and content memory. Our key findings are: (1) unified models trained on short reasoning trajectories generalize to longer inference chains at test time; (2) sequential chain-of-thought reasoning provides a more scalable and compute-efficient TTS strategy than parallel sampling; (3) training on generation and editing trajectories improves out-of-distribution visual reasoning. These results establish multimodal test-time scaling as an effective paradigm for advancing both generation and understanding in unified models.

03.
arXiv (quant-ph) 2026-06-17

$\mathcal{PT}$-Symmetric Spin–Boson Model with a Continuous Bosonic Spectrum: Exceptional Points and Dynamics

arXiv:2512.20277v2 Announce Type: replace Abstract: This work studies a $\mathcal{PT}$-symmetric non-Hermitian spin–boson model, consisting of a non-Hermitian two-level system coupled to a continuous bosonic bath. The static properties of the system are analyzed through a projection method derived from the displacement operator. We find that only a single exceptional point (EP) emerges, in contrast to non-Hermitian spin–boson models with finite modes, which typically exhibit multiple EPs. Notably, only a single real eigenvalue is found before the EP, which differs markedly from typical non-Hermitian systems where a pair of real eigenvalues precedes the EP. The time evolution of observables is further investigated via the Dirac–Frenkel time-dependent variational principle. Compared to its Hermitian counterpart, the non-Hermitian model exhibits distinct dynamical signatures, most notably the emergence of oscillations with periodic amplified amplitude. In the $\mathcal{PT}$-unbroken phase, the system exhibits sustained oscillatory dynamics with suppressed decoherence, whereas in the $\mathcal{PT}$-broken phase, additional dissipative channels accelerate decoherence and drive rapid convergence toward a stable steady state. These results shed light on how $\mathcal{PT}$ symmetry protects coherent light–matter interactions in non-Hermitian quantum systems.

04.
arXiv (quant-ph) 2026-06-19

Asymmetric and chiral dynamics of two-component anyons with synthetic gauge flux

arXiv:2512.19139v3 Announce Type: replace-cross Abstract: In this work, we investigate the non-equilibrium dynamics in a one-dimensional two-component anyon-Hubbard model, which can be mapped to an extended Bose-Hubbard ladder with density-dependent hopping phase and synthetic gauge flux. Through numerical simulations of two-particle dynamics and the symmetry analysis, we reveal the asymmetric transport with broken inversion symmetry and two dynamical symmetries in the expansion dynamics. The expansion of two-component anyons is dynamically symmetric under spatial inversion and component flip, when the sign of anyonic statistics phase or the signs of gauge flux and interaction are changed. In the non-interacting case, we show the dynamical suppression induced by both the statistics phase and gauge flux. In the interacting case, we demonstrate that both chiral and antichiral dynamics can be exhibited and tuned by the statistics phase and gauge flux. The dynamical phase regimes with respect to the chiral-antichiral dynamics are obtained. These findings highlight the rich dynamical phenomena arising from the interplay of anyonic exchange statistics, synthetic gauge fields, and interactions in multi-component anyons.

05.
arXiv (quant-ph) 2026-06-16

Improved Cryogenic Photodiode Optical Biasing for Low-Noise and Low-Jitter Superconducting Nanowire Single-Photon Detectors

arXiv:2606.07140v2 Announce Type: replace Abstract: We experimentally demonstrate an improved optical biasing scheme for superconducting nanowire single-photon detectors (SNSPDs), which employs a cryogenic InGaAs-InP photodiode (PD) as a local bias source. It is found that, under illumination from a stable external light source, this PD generates a stable photocurrent in a cryogenic environment (~2.3 K), with fluctuations in the photocurrent primarily attributed to fluctuations in the incident optical power. Furthermore, by screening and effectively blocking stray photons leaking from the PD, which give rise to background dark counts, we have achieved an SNSPD exhibiting an ultra-low intrinsic dark count rate of 1e-4 cps. Utilizing this improved optical biasing technique, our SNSPD achieved performance comparable to that obtained under conventional electrical biasing: a system detection efficiency of 80.7%, a background dark count rate of 32.6 cps, and a minimum timing jitter of 57.5 ps. These results indicate that cryogenic-PD-based optical biasing serves as a viable, low-noise, and low-jitter alternative to traditional electrical biasing. Moreover, this work offers useful design guidance for the future development of PD-based low-noise bias sources and for the construction of all-photonic SNSPD systems tailored for high-precision quantum photonics applications.

06.
arXiv (quant-ph) 2026-06-11

Circulators Based on Coupled Quantum Anomalous Hall Insulators and Resonators

arXiv:2505.07770v2 Announce Type: replace Abstract: Integrated plasmonics is advancing rapidly, enabling a wide range of functionalities to be incorporated onto a single chip. Applications span information processing, computation, quantum sensing, and dark-matter detection. This progress has driven the development of integrated non-reciprocal devices, which are essential for preventing unwanted feedback that can degrade system performance. While non-reciprocal devices have been realized in edge magnetoplasmon materials via classical interference effects, their operation is often limited by the input power range. Here, we demonstrate that topological circulators utilizing asymmetric coupling offer improved input power range, isolation, and insertion loss. In this configuration, we demonstrate the coupling between a chiral edge magnetoplasmonic resonator and a pair of LC resonators is well described by an effective non-Hermitian two-site Hatano-Nelson model with asymmetric directional couplings, resulting in nonreciprocal behavior. The coherent photon-plasmon interaction enables a circulator with up to 50 dB of isolation across a broad range of excitation power. These results suggest that magnetic topological insulators provide a promising platform for realizing asymmetric non-Hermitian couplings at radio frequencies and for exploring regimes of strong directional suppression and possible exceptional-point physics. More broadly, they highlight the potential of topological-material-based microwave devices for future integration with superconducting quantum information platforms.

07.
arXiv (CS.LG) 2026-06-15

Curvature-Guided Geometric Representation for Protein-Ligand Binding Affinity Prediction

arXiv:2606.14159v1 Announce Type: new Abstract: Protein-ligand binding affinity (PLA) prediction is critical in drug discovery. Despite the notable advancements in machine learning-based approaches, existing methods struggle to jointly characterize local geometric organization and globally coordinated cross-molecular interactions, limiting their ability to model complex binding mechanisms. Here, we propose RicciBind, a geometric representation framework that integrates curvature-guided hierarchical structure learning with optimal transport (OT)-based cross-domain alignment to model molecular interactions. Specifically, RicciBind leverages Ricci curvature to capture local interaction tightness within molecular structures, enhancing structural awareness and organizing atomic interactions into curvature-aware hierarchical representations. An OT-based cluster matching mechanism then aligns protein and ligand clusters across heterogeneous domains under geometric constraints, enabling globally consistent correspondences and revealing higher-order interaction patterns beyond local neighborhoods. By coupling curvature-guided structure encoding with OT-driven cross-domain alignment, RicciBind effectively models complex interaction semantics and substantially improves both the accuracy and interpretability of binding affinity prediction. Extensive experiments demonstrate that RicciBind achieved superior predictive performance and generalization across PLA benchmarks and virtual screening tasks. Ablation studies further confirmed the essential role of Ricci curvature in enhancing molecular interaction representations.

08.
arXiv (quant-ph) 2026-06-16

Intrinsic preservation of plasticity in continual quantum learning

arXiv:2511.17228v2 Announce Type: replace Abstract: Artificial intelligence in dynamic, real-world environments requires the capacity for continual learning. However, standard deep learning suffers from a fundamental issue: loss of plasticity, in which networks gradually lose their ability to learn from new data. Here we show that quantum learning models naturally overcome this limitation, preserving plasticity over long timescales. We demonstrate this advantage systematically across a broad spectrum of tasks from multiple learning paradigms, including supervised learning and reinforcement learning, and diverse data modalities, from classical high-dimensional images to quantum-native datasets. Although classical models exhibit performance degradation correlated with unbounded weight and gradient growth, quantum neural networks maintain consistent learning capabilities regardless of the data or task. We identify the origin of the advantage as the intrinsic physical constraints of quantum models. Unlike classical networks where unbounded weight growth leads to landscape ruggedness or saturation, the unitary constraints confine the optimization to a compact manifold. Our results suggest that the utility of quantum computing in machine learning extends beyond potential speedups, offering a robust pathway for building adaptive artificial intelligence and lifelong learners.

09.
PLOS Medicine 2026-05-27

Sequential chemo-immunotherapy followed by standard versus reduced thoracic radiotherapy for older and/or frail stage III non-small-cell lung cancer: A randomized open-label cohort trial

作者:

by Wei-Xiang Qi, Shuyan Li, Mengdi Wang, Huan Li, Feifei Xu, Lei Yao, Biao Yu, Linlin Chen, Gang Cai, Cheng Xu, Xianwen Sun, Zhiyao Bao, Jiayi Chen, Yi Xiang, Shengguang Zhao Background The appropriateness of concurrent chemoradiotherapy (cCRT) for older or clinically vulnerable stage III unresectable non-small-cell lung cancer (NSCLC) patients remains contentious. Furthermore, the survival implications of de-escalating thoracic radiotherapy (RT) intensity in this population have not been conclusively elucidated. Methods and findings We conducted a phase II randomized, open-label, two-cohort (non-comparative) trial at a tertiary hospital in China (NCT05557552). Between September 30, 2022 and April 30, 2024, we enrolled 56 older and/or frail patients with stage III NSCLC who were ineligible for cCRT. The primary endpoint was the 1-year progression-free survival (PFS) rate estimated using the Kaplan–Meier method. Secondary endpoints included objective response rate (ORR), overall survival (OS), and safety. In the intention-to-treat (ITT) set, which included all 56 randomized patients who received at least one dose of study treatment, the 1-year PFS was 84.3% (95% confidence interval [CI] [70.3%, 98.3%]) in the standard RT group and 70.7% (95% CI [54.3%, 87.1%]) in the reduced RT group. In the per-protocol set (53 patients), the 1-year PFS was 82.9% (95% CI [68.9%, 98.8%]) in the standard RT group and 73.4% (95% CI [58.3%, 92.4%]), with a median follow-up of 24 months. Among 56 patients in the safety analysis set, 71.4% of patients experienced grade 3/4 adverse events (AEs) in the standard RT group and 53.6% in the reduced RT group. One patient (3.6%) in the reduced RT and three patients (10.7%) in the standardized RT experienced grade 5 AEs. The main limitations are the non-comparative design, small sample size, and lack of power to establish non-inferiority or superiority. Conclusion The current study suggested that reduced RT combined with sequential chemo-immunotherapy might be feasible for older/frail patients intolerant to cCRT, showing numerically similar survival outcomes. These exploratory findings warrant confirmation in larger, adequately powered randomized trials. Trial registration The trial had been registered on ClinicalTrials.gov on Sep 30, 2022.ClinicalTrials.gov NCT05557552

10.
medRxiv (Medicine) 2026-06-18

Intra-arterial recombinant human TNK tissue-type plasminogen activator (rhTNK-tPA) thrombolysis for acute medium vessel occlusion (MeVO-TNK): Study rationale and design

Background The optimal management of acute ischemic stroke caused by medium vessel occlusion (MeVO) remains uncertain. Recent randomized trials have failed to demonstrate a clear benefit of endovascular therapy in this population, whereas intra-arterial thrombolysis (IAT) has emerged as a biologically plausible alternative. However, prospective evidence supporting IAT in MeVO is lacking, and the optimal dosing strategy for stand-alone IAT remains undefined. Aim To preliminarily evaluate the efficacy and safety of intra-arterial tenecteplase (IA-TNK) plus standard medical therapy (SMT) compared with SMT alone in patients with acute MeVO stroke, and to explore a stepwise IA-TNK dosing strategy. Design The MeVO-TNK trial is a multicenter, prospective, randomized, open-label, blinded-endpoint (PROBE), exploratory phase II study. A total of 60 participants with imaging-confirmed MeVO will be randomized 1:1 to receive either IA-TNK plus SMT or SMT alone. Participants presenting beyond 6 hours from symptom onset must demonstrate salvageable penumbral tissue on advanced imaging. Those assigned to the intervention group will receive up to two intra-arterial boluses of tenecteplase (0.0625 mg/kg per bolus), with the second bolus administered based on angiographic assessment of reperfusion and safety. Outcomes The primary efficacy outcome is final infarct volume measured at 72{+/-}24 hours after randomization. Secondary efficacy outcomes include the proportions of patients achieving modified Rankin Scale (mRS) scores of 0-1, 0-2 and 0-3 at 90 days, a shift analysis of the mRS distribution at 90 days, early neurological deterioration, and National Institutes of Health Stroke Scale score at 7 days or discharge. The primary safety outcome is symptomatic intracranial hemorrhage within 24 hours. Conclusions This trial will provide preliminary evidence on the biological efficacy, reperfusion potential and safety of stand-alone IA-TNK for acute MeVO stroke, helping to address an important evidence gap and inform the design of future confirmatory studies.