×

Academic Intelligence · Curated Daily

探索全球前沿学术脉络

AcademicHub 汇聚顶级期刊与预印本平台的实时文献。定制您的专属科研雷达,利用大语言模型自动生成交叉领域文献分析简报。

作者: Andreas Maier ×
换一批
01.
arXiv (CS.CV) 2026-06-17

Vision-language models for chest radiography do not always need the image

Medical vision-language models report strong chest radiograph accuracy, and this is increasingly read as evidence that they use the image. That inference is unsafe: a model exploiting finding-name priors scores like one that reads the scan, and no standard benchmark separates them. We introduce a causal audit that intervenes on the image, occluding the relevant region, occluding an irrelevant one, and swapping in another patient's same-label scan, and combines three behavioral metrics to test whether a correct answer depends on the image. Across nine systems, a text-only model with no image access reaches within 5.7 accuracy points of the best multimodal one, and a 119-billion-parameter multimodal model is statistically indistinguishable from a 7-billion text-only baseline. The audit splits the cohort into three models that ignore the image, one that is unstable, and five that use it selectively, for a subset of findings; the categories hold across a second dataset, resolution, and prompt phrasing. Against board-certified radiologists, a text-only model is statistically indistinguishable from a radiologist's accuracy while grounding at zero, whereas the image-using models ground at radiologist-comparable rates. Reported confidence flags ungrounded answers only when a model uses the image. Grounding audits, not accuracy, should gate clinical deployment.

02.
arXiv (CS.CV) 2026-06-16

An Open-Source Monitoring Framework for Data Exploration and Progress Tracking in Multi-Center Radiology Studies

Multi-center studies are crucial for advancing medical and radiological research. Data exploration, collaboration discovery, and study progress monitoring are essential for maximizing their potential. However, in practice these processes often rely on manual communication and shared tables, which quickly become outdated and hinder efficient coordination in large distributed studies. This highlights the need for dedicated monitoring solutions that provide transparent and up-to-date insights into study progress. We propose a lightweight, open-source monitoring architecture for multi-center studies based on the widely used Grafana-Prometheus stack. The framework collects aggregated monitoring metrics from distributed study sites and visualizes them through configurable dashboards. As a real-world deployment example, the framework is integrated into the medical imaging platform Kaapana and evaluated within a large multi-center research network. By deploying our solution within the Germany-wide RACOON consortium, we demonstrate its ability to enable privacy-preserving data exploration and study progress monitoring across all 38 German university clinics. The monitoring framework supports transparent coordination of distributed research activities and can facilitate more efficient management of large-scale multi-center studies. The source code and Kaapana integration are publicly available at https://github.com/MIC-DKFZ/study-monitoring-kaapana.

03.
arXiv (CS.CV) 2026-06-16

CT-VDETR: Semi-supervised 3D Trauma Detection in Computed Tomography (CT) scans using Dense Vertex Relative Position Encoding

Accurate detection and localization of traumatic injuries in abdominal CT remain challenging because voxel-level annotations are limited and expensive to obtain. We present a label-efficient framework for 3D abdominal trauma detection that combines self-supervised pretraining with semi-supervised transformer-based detection. First, we use Masked Image Modeling (MIM) on 1098 CT volumes to pretrain a 3D U-Net encoder for anatomical representation learning. Next, we adapt V-DETR to dense volumetric CT through a feature adapter that converts the encoder feature grid into a compact token sequence for transformer decoding. The pretrained encoder is then integrated with V-DETR and 3D Vertex Relative Position Encoding (3D V-RPE) to improve the localization of irregularly shaped injuries. Finally, semi-supervised teacher-student consistency regularization leverages 2,000 additional unlabeled volumes during detector training. To the best of our knowledge, this is the first application of a 3D DETR-style detector to the RSNA abdominal trauma detection task. On this benchmark, the proposed method achieves 31.33% test mAP@0.50 using only 78 labeled training volumes, corresponding to a 1.53x improvement over supervised-only training. These results show that combining medical-domain pretraining with semi-supervised learning is an effective strategy for label-scarce 3D medical detection.

04.
arXiv (CS.AI) 2026-06-19

Controlled Comparison of Machine Learning Models for Fault Classification and Localization in Power System Protection

arXiv:2510.00831v2 Announce Type: replace Abstract: The increasing complexity of modern power systems, driven by the integration of inverter-based and distributed energy resources, challenges the reliability of conventional protection schemes and motivates the use of machine learning for protection tasks. However, published results are often difficult to compare because datasets, sensing assumptions, and decision horizons vary across studies. This paper presents a controlled comparison of machine learning models for fault classification (FC) and fault localization (FL) under identical sensing, timing, and validation conditions on a common electromagnetic transient dataset, using decision windows of 10-50 ms to reflect protection-relevant time scales. For FC, the best-performing nonlinear models achieve F1 scores above 0.98 already at 10 ms, while lower-capacity models degrade at shorter horizons but improve with longer windows, indicating that relevant fault-type information is already present in the earliest transient. For FL, the top-performing models reach a stable localization error of about 10 % of normalized line length across all evaluated horizons, while weaker models form a clearly separated second performance tier. Line-resolved analysis shows that localization accuracy varies across grid segments, indicating topology-dependent difficulty rather than insufficient temporal context alone. These findings provide a controlled reference for comparing machine learning models across two protection tasks with fundamentally different information requirements.

05.
arXiv (CS.CV) 2026-06-18

Bidirectional Cross-Attention Fusion of High-Resolution RGB and Low-Resolution Hyperspectral Inputs for Multimodal Semantic Segmentation

Multimodal semantic segmentation with heterogeneous sensors must reconcile complementary information across modalities that differ in spatial resolution and channel dimensionality. In particular, high-resolution RGB imaging provides detailed spatial structure but often fails to distinguish visually similar materials, whereas hyperspectral imaging (HSI) provides discriminative spectral signatures but at lower spatial resolution. We present Bidirectional Cross-Attention Fusion (BCAF), which aligns high-resolution RGB with low-resolution HSI at their native grids via localized, bidirectional cross-attention, avoiding pre-upsampling or early spectral collapse. BCAF uses two independent backbones: a standard Swin Transformer for RGB and an HSI-adapted Swin backbone that preserves spectral structure through 3D tokenization with spectral self-attention. Although our evaluation targets RGB-HSI fusion, BCAF is modality-agnostic and applies to co-registered RGB with lower-resolution, high-channel auxiliary sensors. On the benchmark SpectralWaste dataset, BCAF delivers strong performance, achieving 75.4% at 55 images/s. We further evaluate a novel industrial dataset: K3I-Cycling (first RGB subset already released on Fordatis). On this dataset, BCAF reaches 62.3% mIoU for material segmentation (paper, metal, plastic, etc.) and 66.2% mIoU for plastic-type segmentation (PET, PP, HDPE, LDPE, PS, etc.). These results show that preserving native-grid spatial detail and spectral structure improves multimodal segmentation under real-time constraints. Code and model checkpoints are publicly available at https://github.com/jonasvilhofunk/BCAF_2026.